Integral Flow Straightener, Ideal for Turbulent Measuring Conditions

The Series STRA Duct Mounted Airflow Measurement Stations utilize an airflow averaging element generating a velocity pressure signal similar to the orifice, venturi, and other primary elements. Single or multiple airflow elements are factory mounted and pre-piped in a casing designed for flanged connection to the ductwork. Multiple elements are joined together for connection to a differential measurement device (gage, transmitter, etc.) for flow measurement and indication purposes. It has been developed with a honeycomb airflow straightening section for use in duct systems having highly turbulent conditions at the point of measurement.

Product Applications

  • Building air intake and exhaust flow rate measurement
  • HVAC air flow measurement
Grouped product items
Model Description Availability* Qty Price

Specifications

Accuracy:
Within 2% of actual flow when installed in accordance with published recommendations.
K Factor:
0.97.
Velocity Range:
100 to 10,000 fpm (0.51 to 51 m/s).
Wetted Materials:
Elements: 6063-T5 anodized aluminum; Casings: 16 ga G90 galvanized steel, 3003 aluminum air flow straightener.
Coatings:
Herewith VRL 500 phenolic coating Imron 333 polyurethane enamel.
Temperature Limits:
Galvanized Casings and Aluminum Elements 350°F (177°C) continuous operation (in air), 400°F (204°C) intermittent operation (in air).
Humidity Limits:
All Airflow Stations 0 to 100% non condensing.
Process Connections:
1/4" compression fittings.

Features

  • Honeycomb airflow straightening section with 1/2" opening by 3" depth
  • Low signal-to-noise ratio
  • Factory mounted and pre-piped in a flanged duct section (casing)
  • Standard construction includes galvanized casing and 6063-T5 anodized aluminum flow sensors
  • Standard airflow stations can be operated (in air) continuously in temperatures up to 350°F or intermittently in temperatures up to 400°F

Options

  • F - (Oval Stations Only).
  • IM - Internal Pressure Connections.

Product Literature

Manuals

Catalog Pages

Model Chart

Rectangular or Oval Models:
EXAMPLE STRA O 12 X16 IM Series STRA-R12X16-IM Duct Mounted Airflow Measurement Station, 12" x 16" oval duct, with internal pressure connections.
SERIES STRA         Duct Mounted Airflow Measurement Station
CONFIGURATION   O
R
      Oval
Rectangular
DUCT HEIGHT     8
10
12
14
15
16
18
20
22
24
26
28
30
32
34
36
37
40
44
48
52
56
60
66
72
78
84
90
96
102
108
114
120
200MM
250MM
300MM
350MM
370MM
400MM
425MM
450MM
500MM
550MM
565MM
600MM
610MM
615MM
700MM
750MM
765MM
1000MM
1100MM
1200MM
1250MM
1300MM
1450MM
    8"
10"
12"
14"
15"
16"
18"
20"
22"
24"
26"
28"
30"
32"
34"
36"
37"
40"
44"
48"
52"
56"
60"
66"
72"
78"
84"
90"
96"
102"
108"
114"
120"
200MM
250MM
300MM
350MM
370MM
400MM
425MM
450MM
500MM
550MM
565MM
600MM
610MM
615MM
700MM
750MM
765MM
1000MM
1100MM
1200MM
1250MM
1300MM
1450MM
DUCT WIDTH       X8
X10
X12
X14
X15
X16
X18
X20
X21
X22
X24
X26
X28
X30
X32
X34
X35
X36
X39
X40
X42
X44
X48
X50
X52
X56
X60
X63
X66
X68
X72
X78
X84
X90
X96
X102
X108
X114
X120
X250MM
X350MM
X400MM
X450MM
X500MM
X550MM
X600MM
X610MM
X615MM
X675MM
X750MM
X770MM
X900MM
X950MM
X955MM
X1000MM
X1100MM
X1150MM
X1200MM
X1370MM
X1380MM
X1400MM
X1450MM
X1470MM
X1600MM
X2400MM
  8"
10"
12"
14"
15"
16"
18"
20"
21"
22"
24"
26"
28"
30"
32"
34"
35"
36"
39"
40"
42"
44"
48"
50"
52"
56"
60"
63"
66"
68"
72"
78"
84"
90"
96"
102"
108"
114"
120"
250MM
350MM
400MM
450MM
500MM
550MM
600MM
610MM
615MM
675MM
750MM
770MM
900MM
950MM
955MM
1000MM
1100MM
1150MM
1200MM
1370MM
1380MM
1400MM
1450MM
1470MM
1600MM
2400MM
OPTIONS         F
IM
1-1/2" Flange for Oval Mount Station Only
Internal Pressure Connections


Circular Models:

EXAMPLE STRA C 12 Series STRA-C12 Duct Mounted Airflow Measurement Station, 12" diameter duct.
SERIES STRA     Duct Mounted Airflow Measurement Station
CONFIGURATION   C   Circular
DUCT DIAMETER     8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
40
41.5
42
44
48
54
56
60
66
72
78
84
90
96
102
108
114
120
8"
10"
12"
14"
16"
18"
20"
22"
24"
26"
28"
30"
32"
34"
36"
40"
41.5"
42"
44"
48"
54"
56"
60"
66"
72"
78"
84"
90"
96"
102"
108"
114"
120"
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price