Series CLT Continuous Level Transmitter
Customize To Fit Application, 316 SS or Buna-N Floats
The Series CLT Continuous Level Transmitter provides up to the minute tank level
monitoring with a customized level transmitter. Transmitters can be configured for 4 to
20 mA or proportional voltage output, 316 SS or Buna-N stem and floats, and lengths
up to 72" (183 cm).
Product Applications
- General purpose level monitoring
- Low specific gravity applications
- Gas and oil
Specifications
- Service:
- Compatible liquids.
- Resolution:
- 1/4" (6.35 mm).
- Temperature Limits:
- Buna-N Floats: 180°F (82°C) in water, -40 to 230°F (-40 to 110°C) in oil; SS Floats: -40 to 230°F (-40 to 110°C).
- Pressure Limits:
- Buna-N Floats: 150 psig (10 bar); SS Floats: 300 psig (21 bar).
- Power Requirements:
- Proportional Voltage Output Models: 10 to 30 VDC; 4 to 20 mA Output Models: 10 to 40 VDC.
- Loop Resistance:
- 1.4 kΩ maximum.
- Electrical Connections:
- Proportional Voltage Output Models: 24" (16 cm) free leads #22 AWG, TFE jacketed; 4 to 20 mA Output Models: junction box.
- Enclosure Rating:
- 4 to 20 mA Models: junction box.
- Mounting Orientation:
- Vertical ±20°, maximum length of 72" (183 cm).
- Specific Gravity:
- Buna-N Floats with SS or Brass Stem: 0.55 minimum; SS Floats with SS Stem: 0.75 minimum.
Features
- Customized stem length, actuation point, distance between floats, and lead wire lengths
- 4 to 20 mA or proportional voltage output outputs continuous level indication
Model Chart
EXAMPLE | CLT | V | S | 5 | F3 | 20.25 | 02.00 | 25.75 | Series CLT-VS5F3-20.25-02.00-25.75 Continuous Level Transmitter, voltage output, 316SS, 3" 150# SS flange, 316SS float, 20.25" indication length, 2.00" distance from bottom of mounting connection to upper float stop, 27.75" overall length. | |||
CONSTRUCTION | CLT | Continuous Level Transmitter | ||||||||||
OUTPUT | V C |
Voltage, proportional signal of 0 to supply voltage 4-20 mA (Junction box provided) |
||||||||||
STEM AND CONNECTION MATERIAL |
B S |
Brass with Beryllium copper stops 316 SS with SS ARMCO PH-15-7MO stops |
||||||||||
CONNECTION TYPE | 1 2 3 4 5 |
1/2" NPT 1-1/4" NPT 2" NPT 3" 150# Flange, carbon steel (max. press. 150 psi [10.3 bar]) 3" 150# Flange, 316 SS (max. press. 150 psi [10.3 bar]) |
||||||||||
FLOAT TYPE | Material | Min. s.g. | Max. Press. psi (bar) | Float Factor in (mm) | ||||||||
F1 F2 F3 |
Buna-N Buna-N 316 SS |
0.55 0.55 0.75 |
150 (10.3) 150 (10.3) 300 (20.7) |
2.0 (50.8) 2.5 (63.5) 3.5 (52.4) |
||||||||
INDICATION LENGTH | 00.00 | Length that the unit sends an output for level. Maximum is 68" (173 cm) | ||||||||||
TOP FLOAT STOP "C" DIMENSION |
00.00 | Distance from bottom of mounting connection to upper float stop. Minimum is 1/4" (6.4 mm) | ||||||||||
OVERALL LENGTH "B" | 00.00 | To calculate overall length, add indication length, top float stop dimension "C", and float factor. Maximum length is 72" (1.82 m) |
Write Your Own Review
Model | Description | Availability* | Price |
---|