  1. The DPMA-502 panel meter, what is the environmental rating? NEMA 1?

    The Series DPMA doesn't have a NEMA rating.

    Read more »
  2. How often should I replace the filter on my 1205A-0 handheld CO analyzer?

    This filter should be replaced if it begins to appear wet or dirty and can be replaced with Model F195 Air Filter.

    Read more »
  3. How often do our pressure gages need to be recalibrated?

    There is no set life span for any of our products, as it varies based on usage. For critical applications, the unit should be tested 2-3 times a year. Under normal circumstances, the units should be tested annually.

    Read more »
  4. Does Dwyer offer any certification on their products?

    Yes, at an additional cost, contact our service group for pricing; we are able to provide NIST certification on many of our products. We can also issue a certificate of conformance at no charge for all of our products stating that they meet our published specifications.

    Read more »
  5. How are the F6 & F7 vertical level switches converted from N.O. to N.C. or vice versa?

    The float is removed and replaced upside down.

    Read more »
  6. The datasheet for CFS2 level switch only shows electrical rating assuming 125VAC or 250VAC. Can this type of switch be used with 24V DC power low current application (DI of PLC)? What is current range for 24V DC?

    Unfortunately, the CFS2 series is not DC rated. It can only be used with AC voltage.

    Read more »
  7. The catalog page for the CFS2 level switches states, "Optional cables available include those with drinking water suitability." Which cable should I specify for use in a drinking water application?

    Our cables that are compatible with drinking water must be purchased in quantities of 1000pcs. The cables we carry in stock that have a minimum order quantity of 1 pc are not drinking water approved.

    Read more »
  8. How does the F6-HPS-11 Level Switch attach to my tank?

    Drill a 1/2" hole in the side of your tank. With the F6-HPS-11 body inside the tank, insert the screw and exposed wires through this hole and secure the unit in place with the corresponding nut.

    Read more »
  9. Question 1. What is the input impedance of the SPPM meter with voltage input? I'm replacing an old analog meter with a 0-100 uA movement with a more reliable digital panel meter. Question 2. The analog meter I want to replace has a two-range non-linear vi

    The SPPM with the voltage input has a 10MΩ input impedance. Also, a non-linear calibration curve can be created by merely using the software in the SPPM. One can use the sensor linearization and use up to 20 calibration points and even have your results converted into a .csv file.

    Read more »
  10. What else needs to be specified when ordering an L4-TOP?

    The vertical and horizontal lengths of the float arm.

    Read more »