Model 652-0 High Accuracy Programmable Transmitter
SKU
Model652-0
RTD, Thermocouple, Voltage or Potentiometer Input, Galvanically Isolated
No longer available.
$0.00
Specifications
- Input/Output Isolation:
- 500 VAC RMS.
- Thermocouple Input Range:
- J: -328 to 2192°F (-200 to 1200°C); K: -328 to 2498°F(-200 to 1370°C); T: -328 to 752°F (-200 to 400°C); R and S: -14 to 3200°F (-10 to 1760°C); E: -328 to 1832°F (-200 to 1000°C); F: -148 to 1112°F (-100 to 600°C); N: -292 to 2372°F (-180 to 1300°C).
- RTD Input Range:
- (Pt100 Ω): -328 to 1562°F (-200 to 850°C).
- Output:
- Linearized 4 to 20 mA.
- Output Impedance:
- 700 Ω @ 24 VDC.
- Power Requirements:
- 10 to 35 V.
- Accuracy:
- T/C: ±0.04% full range input, ±0.04% rdg.; RTD; ±0.01 full range input, ±0.05% of rdg.; Voltage:10µV, ±0.07% rdg.; Potentiometer: 0.1% full range input.
- Thermal Drift:
- Zero: 0.1µV/°C (RTD zero drift is 0.008°F/°F); Span: 100ppm/°C.
- Temperature Limit:
- Ambient: -40 to 185°F (-40 to 85°C).
- Response Time:
- <1 second.
- Update Time:
- 250 ms max.
- Filtering:
- Off, 2 seconds, 10 seconds, or adaptive.
- Cold Junction Error:
- ±29°F (±0.5°C).
- Housing:
- PPE & PS.
- Weight:
- 0.92 oz (26 g).
- Agency Approvals:
- CE.
Model | Description | Availability* | Price |
---|