Series SBLT2 & SBLTX Submersible Level Transmitter

Series SBLT2 & SBLTX Submersible Level Transmitter

Series PBLT2 & PBLTX Submersible Level Transmitter

Perfect for Sludge and Slurries, Lightning Protected, Intrinsically Safe

PBLT2 and PBLTX Submersible Level Transmitters are manufactured for years of trouble free service in the harshest applications. Both measure the height of liquid above the position in the tank referenced to atmospheric pressure. The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing. Perfect for wastewater and slurry applications with features to protect the unit from these demanding applications. Large diameter 316 SS diaphragm seal is non-clogging and damage resistant to floating solids.

The PBLT2 incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty). The PBLTX is UL approved intrinsically safe for use in hazardous locations when used with proper barrier.

Units come equipped with a 270-pound tensile strength shielded and vented cable. Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank. The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer.

If you don't see the exact model in the ordering section, please use one of our product configurators below:

(Not UL Approved)

(UL Approved)


Product Applications

  • Wastewater
  • Sludge pits, clarifiers, digesters
  • Alum tanks
  • Chemical storage tanks
  • Oil tanks
  • Lime slurry
  • Sumps
  • Reservoirs
Starting at $785.60
Filter By
Grouped product items
Model Description Availability* Qty Price
PBLT2-10-100-PU Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 100 ft (30.5 m) polyurethane cable. 1-3 days*
$1,071.95
PBLT2-10-40 Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 40 ft (12.2 m) ETFE cable. 1-3 days*
$1,084.95
PBLT2-10-40-PU Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 40 ft (12.2 m) polyurethane cable. 1-3 days*
$864.95
PBLT2-10-60-PU Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 60 ft (18.3 m) polyurethane cable. 1-3 days*
$933.95
PBLT2-15-60 Submersible level transmitter, range 15 psi (34.63 ft wc) [10.56 m wc], 60 ft (18.3 m) ETFE cable. 1-3 days*
$1,263.95
PBLT2-15-60-PU Submersible level transmitter, range 15 psi (34.63 ft wc) [10.56 m wc], 60 ft (18.3 m) polyurethane cable. 1-3 days*
$933.95
PBLT2-5-40 Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) ETFE cable. 1-3 days*
$1,084.95
PBLT2-5-40-PU Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) polyurethane cable. 1-3 days*
$864.95
PBLTX-15-60 Submersible level transmitter, 15 psi pressure range, 60 feet of ETFE cable, intrinsically safe. 1-3 days*
$1,448.05
PBLTX-5-40 Submersible level transmitter, 5 psi pressure range, 40 feet of ETFE cable, intrinsically safe. Less Than 1 Week*
$1,269.05

Specifications

Service:
Compatible liquids.
Wetted Materials:
Body: 316 SS, 316L SS; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer.
Accuracy:
±0.25% FS (includes linearity, hysteresis, and repeatability).
Temperature Limit:
PBLT2: 0 to 200°F (-18 to 93°C); PBLTX: ETFE -4 to 176°F (-20 to 80°C); Polyurethane: -4 to 149°F (-20 to 65°C)
Compensated Temperature Range:
PBLT2: 0 to 180°F (-18 to 82°C), PBLTX: 0 to 176°F (-18 to 80°C).
Thermal Effect:
±0.02% FS/°F.
Pressure Limit:
2X FS.
Power Requirement:
PBLT2: 13 to 30 VDC, PBLTX: 10 to 28 VDC.
Output Signal:
4 to 20 mA DC, two wire.
Response Time:
50 msec.
Loop Resistance:
900 Ω.
Electrical Connection:
Wire pigtail.
Mounting Orientation:
Suspended in tank below level being measured.
Electrical Protection:
PBLT2: Lightning and surge protection, PBLTX: none.
Weight:
4.3 lb (2.0 kg).
Compliance:
PBLT2: CE, PBLTX: CE, cULus intrinsically safe for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1; ATEX: II 1 G Ex ia IIC T4 Ga and II 1 D Ex ia IIIC T135C Da (According to control drawing 001833-44)**.
Enclosure Rating:
IP68; 20 m for 24 hrs per IEC 60529.
**Up to 275' (83.8 m) for ETFE cable; Up to 470' (143.3 m) for polyurethane cable.

Features

  • Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids
  • Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models
  • Eliminates particulate or water droplets from entering the transducer using maintenance-free filter
  • Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier
  • Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility
  • Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation

Options

  • -Intrinsically Safe Approval - Change model number from PBLT2 to PBLTX.
  • -Custom Ranges or Cable Lengths.

Model Chart

   
     PBLT2-XX-XX-OPT      PBLT2 SUBMERSIBLE LEVEL TRANSMITTER
          
          1ST SYMBOL (1ST X) SENSOR (DECIMALS ALLOWED)
             ?     SENSOR RANGE
                   5-145 PSI OR 3.5-100 METERS
                    
          2ND SYMBOL (2ND X) SENSOR UNITS
                   SENSOR RANGE IN PSI IF BLANK
             M     SENSOR RANGE IN METERS
                    
          3RD SYMBOL (3RD X) CABLE LENGTH
             ?     10-2000 FT OR 3-600 METERS
                    
          4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
                   CABLE LENGTH IN FEET IF BLANK
             M     CABLE LENGTH IN METERS
 
          OPTIONS (OPT) KITS
             -PU    POLYURETHANE CABLES  (STD IS ETFE)
             -2YR   2 YEAR WARRANTY
             -LSP   LIGHTNING SURGE PROTECTION GUARANTEE 2YR


      
     PBLTX-XX-XX-OPT      PBLTX SUBMERSIBLE LEVEL TRANSMITTER
                              (INTRINSICALLY SAFE APPROVAL)
          
          1ST SYMBOL (1ST X) SENSOR (DECIMALS ALLOWED)
             ?     SENSOR RANGE
                   5-145 PSI OR 3.5-100 METERS
                    
          2ND SYMBOL (2ND X) SENSOR UNITS
                   SENSOR RANGE IN PSI IF BLANK
             M     SENSOR RANGE IN METERS
                    
          3RD SYMBOL (3RD X) CABLE LENGTH
             ?     10-195 FT ETFE   OR 10-330 FT PU
                   3-59 METERS ETFE OR 3-100 METERS PU

          4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
                   CABLE LENGTH IN FEET IF BLANK
             M     CABLE LENGTH IN METERS
 
          OPTIONS (OPT) KITS
             -ATEX  ATEX INTRINSICALLY SAFE
             -PU    POLYURETHANE CABLE  (STD IS ETFE)
             -2YR   2 YEAR WARRANTY     

Questions

Question
Our client has an MBLT pressure transmitter that appears to be malfunctioning due to scale buildup. The transmitter is installed to measure leachate level in a one-year old municipal sanitary landfill. What can we use to remove scale from the transmitter without damaging the transmitter?
Answer
If the issue is due to build-up which consequently plugs the small sensing holes, you might take a look at our PBLT2 or FBLT series. They are both more rugged and designed for sludge and slurries, whereas the MBLT and SBLT2 are better suited for cleaner applications such as ground water and wells.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-297 Desiccant filter for vent tube filter for submersible level transmitters. Removes humidity for protection of the sensor. Changes color to show saturation. 1-3 days*
$30.20
A-625 316 SS cable hanger use with NPT option for attaching chain for easy pulling out of application. 1-3 days*
$36.10
MTL5541 Galvanic barrier 1-3 days*
$1,084.70
MTL7706 Intrinsically safe zener barrier for hazardous locations 1-3 days*
$646.05