EXAMPLE |
PG |
|
153 |
P1 |
|
PG-153-P1 (Vacuum) (Pressure) (Differential Pressure) Control, fixed deadband, automatic reset, SPDT mercury switch, adjustable range 1.0-30" w.c. (25-760 bar). |
MODEL |
PG |
|
|
|
|
General purpose enclosure, NEMA-1 (standard) |
PR |
|
|
|
|
Manual reset, operates on pressure increase automatically, resets on decrease1 |
PRL |
|
|
|
|
Manual reset, operates on pressure decrease automatically, resets on increase1 |
HOUSING
OPTIONS |
|
W |
|
|
|
Weather-resistant enclosure, NEMA-2, 3R |
CIRCUIT
(SWITCHING)
OPTIONS
(For Electrical
Codes see Chart
Below) |
|
|
2 |
|
|
SPST mercury switch, elect. code K†, opens on vacuum, pressure or differential pressure increase |
|
|
2P |
|
|
SPST mercury switch, elect. code L†, opens on vacuum, pressure or differential pressure increase |
|
|
3 |
|
|
SPST mercury switch, elect. code K†, closes on vacuum, pressure or differential pressure increase |
|
|
3P |
|
|
SPST mercury switch, elect. code L†, closes on vacuum, pressure or differential pressure increase |
|
|
153 |
|
|
SPDT mercury switch, elect. code M† |
|
|
103 |
|
|
DPST, two SPST mercury switches, elect. code L†, both close on increase, FM approved, PG, PGW only |
|
|
105 |
|
|
DPST, two SPST mercury switches, one elect. code L†, one elect. code N, both open on decrease |
|
|
119 |
|
|
(2) Mercury Switches, SPST NO (DPST) |
|
|
127 |
|
|
DPST, two SPST mercury switches, elect. code L†, both open on increase |
|
|
129 |
|
|
DPST, two SPST mercury switches, one elect. code L†, one elect. code N, both open on increase |
|
|
131 |
|
|
(2) Mercury Switches, SPST NC (DPST) |
|
|
152 |
|
|
(1) Mercury Switch, SPDT (4-wire) |
|
|
156 |
|
|
SPDT, two SPST mercury switches, elect. code L†, one- opens on increase, one closes on increase |
|
|
158 |
|
|
SPDT, two SPST mercury switches, one elect. code L† - opens on increase, one elect. code N - closes on increase |
|
|
161 |
|
|
SPDT, two SPST mercury switches, one elect. code L† - opens on decrease, one elect. code N - closes on decrease |
|
|
190 |
|
|
(2) Mercury Switches, SPST NC; SPST NO (SPDT) |
|
|
804 |
|
|
DPDT, two SPDT mercury switches, elect. code M† |
|
|
(__) |
|
|
Other circuits available, consult factory |
|
|
7000-153 |
|
|
SPDT, snap acting switch, rated 15A at 120 VAC, 8A at 240 VAC, 0.5A at 120 VDC, .25A at 240 VDC (1) |
|
|
7000-153HS |
|
|
SPDT, Hermetically sealed snap switch, rated 5A at 125/250 VAC, 5A resistive at 30 VDC |
|
|
7000-153HG |
|
|
SPDT, Hermetically sealed gold contact snap switch, rated 1A at 125 VAC, 1A resistive at 30 VDC |
|
|
7200-804 |
|
|
DPDT, two SPDT snap acting switches, rated 5A at 120/240 VAC, 30 VDC resistive (1) |
ADJUSTABLE DIFFERENTIAL
PRESSURE RANGES WITH MAXIMUM
SUSTAINED PRESSURES |
|
|
|
P1 |
|
Adjustable range 1.0-30" w.c. (25-760 bar), maximum sustained pressure 2 psig* (0.14 bar) |
|
|
|
P2 |
|
Adjustable range 0.5-5 psig (.03-.35 bar), maximum sustained pressure 10 psig* (0.69 bar) |
OPTIONS |
|
|
|
|
ATR |
Aluminum Tag (Riveted) |
|
|
|
|
ATW |
Aluminum Tag (Wired) |
|
|
|
|
PE |
Prep for EP |
|
|
|
|
PRESET |
Preset and Pressure Check Set Point |
|
|
|
|
PT |
Paper Tag |
|
|
|
|
STR |
Stainless Steel Tag (Riveted) |
|
|
|
|
STW |
Stainless Steel Tag (Wired) |
|
|
|
|
23720 |
Fungus Proofing Special 23720 |
|
|
|
|
23444 |
O2 Acetylene Special 23444 |
|
|
|
|
RCH |
Rigid Conduit Hub |