Series AP1 Thermo-Anemometer Probe

Series AP1 Thermo-Anemometer Probe

Series TABKIT Test, Adjust, and Balance Kit

A Complete Balancing Technician Solution
No longer available.
Grouped product items
Model Description Availability* Qty Price

Specifications

AIR
Series DP3
Accuracy*:
±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
Pressure Limits:
±10 in w.c. (±2.5 kPa).
Temperature Limits:
Operating: -4 to 140°F (-20 to 60°C); Storage: -40 to 185°F (-40 to 85°C).
Model AP3
Range:
Air velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric air: 999,999 in selected flow units; Temperature: -20 to 212°F (-29 to 100°C).
Accuracy:
Air velocity*: ±3% FS within temperature range of 40 to 90°F (4 to 32°C) -TAB option: 50 to 3900 FPM (0.25 to 20 m/s); Temperature: ±0.5°F (±0.28°C).
Model VP3
Range:
Air velocity: 40 to 5000 FPM (0.2 to 25 m/s); Volumetric air: 999,999 in selected flow units; Temperature: -20 to 212°F (-29 to 100°C); Relative humidity: 0 to 100% RH.
Accuracy:
Air velocity*: 0.25 to 10 m/s: ±1.5% of reading ±20 FPM (±0.1 m/s); 10 to 20 m/s: 1.5% of reading ±40 FPM (±0.2 m/s); 20 to 25 m/s: ±1.5% of reading ±60 FPM (±0.3 m/s);
Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C);
Relative humidity: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% RH and 90 to 100%).
Resolution:
1 FPM (0.001 m/s).
TEMPERATURE
TM99A and 1075
Range:
0 to 200°F (-20 to 100°C).
Accuracy*:
±0.5% of reading + 2.0°F (±0.5% of reading + 1.0°C).
Resolution:
0.1°F (0.1°C).
HUMIDITY
Model RP3
Range:
RH: 0 to 100% (noncondensing); Temperature: -22 to 140°F (-30 to 60°C).
Accuracy:
RH*: ±2% @ 25°C (10 to 90% RH); ±4% (0 to 10, 90 to 100% RH); Temperature: ±0.54°F @ 77°F (±0.3°C).
ELECTRICAL
Model CM-1
AC Voltage:
0.1-600 V ± (1.0% + 5 dgt).
DC Voltage:
0.1-600 V ± (1.0% + 3 dgt).
AC Current:
0.1-400 A ± (2.0% + 10 dgt).
Resistance:
0.1-400 Ω ± (1.0% + 5 dgt).
ROTATION
Model TAC-L
Range:
Non-contact (RPM): 2.5 to 99,999 RPM; Contact (RPM): 0.5 to 19,999 RPM; Surface speed (m/min): 0.05 to 19,999 m/min.
Resolution:
Non-contact* (RPM): 0.1 RPM (2.5 to 999.9 RPM), 1 RPM (1000 to 19,000 RPM); Surface speed (m/min): 0.01 m/min (0.05 to 99.99 m/min), 0.1 m/ min (100.0 to 1999.9 m/min).
HYDRONIC
A-490W-6
Range:
0.4 to 200 psi, 3 to 1400 kPa.
0.4 to 75 psi, 3 to 500 kPa.
Accuracy:
2% of reading ±1 psi, 2% of reading ±7 kPa.
2% of reading ±0.5 psi, 2% of reading ±3.5 kPa.
Resolution:
0.1 psi, 1.0 kPa.
0.01 psi, 0.1 kPa.
*NIST calibrated.

Features

  • Everything a balancing technician needs in a single case
  • Best in class low flow velocity readings
  • Repeatable measurements

Product Literature

Manuals

Catalog Pages

SlideShare

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-303 Portable static pressure tip, for 3/16" ID rubber or plastic tubing with 4" insertion. 1-3 days*
$13.40
160F Straight stainless steel pitot tube, 18" 2-3 Weeks*
$275.55
160G Averaging air flow grid. 2-3 Weeks*
$332.30
160-18 Stainless steel Pitot tube, 5/16" dia., 18-5/8" insertion length. 2-3 Weeks*
$138.30
490W-6-HKIT-NIST Hydronic differential pressure manometer, full kit with (2) each 200 psi sensors with NIST calibration Less Than 1 Week*
$3,973.85