We use cookies to make your experience better. By using our site, you consent to cookies. Learn more.
Series AP Diaphragm Operated Pressure Switch
Visible Setpoint Adjustment, Compact
Reliable and convenient, the Series AP Diaphragm Operated Pressure Switch is a compact switch for instrument air or other low pressure applications. Visible set point and external adjustment add convenience. Used on air, non-corrosive gas or liquid service compatible with wetted parts. Units are available in weather-proof and explosion-proof housing.
Product Applications
- Low pressure applications
- Instrument air
Starting at $585.50
Specifications
- Wetted Materials:
- Nylon reinforced Buna-N and steel. PTFE and 316 SS optional.
- Temperature Limits:
- -30 to 150°F (-35 to 66°C).
- Pressure Limit:
- See Catalog page.
- Enclosure Rating:
- General purpose. Weatherproof and explosion-proof optional.
- Switch Type:
- SPDT mercury switch or SPDT snap switch. Other switch types available.
- Electrical Rating:
- Mercury switch: 4 A @ 120 VAC/DC, 2 A @ 240 VAC/DC. Snap switch: 15 A @ 120 VAC, 8 A @ 240 VAC, 0.5 A @ 120 VDC, 0.25 A @ 240 VDC.
- Electrical Connections:
- Screw terminal.
- Conduit Connection:
- 7/8" (22.23 mm) hole for 1/2" (12.7 mm) conduit hub.
- Process Connection:
- 1/4" female NPT.
- Mounting Orientation:
- Vertical for mercury switch models, any position for snap switch models.
- Set Point Adjustment:
- External screw.
- Weight:
- General Purpose: 2 lb (0.9 kg).
- Deadband:
- See Catalog page.
- Compliance:
- FM, UL. For FM consult factory.
Features
- Explosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation
- External switch set point adjustment reduces set-up time
Model Chart
EXAMPLE | AP | 41 | 153 | 36 | AP-41-153-36, Diaphragm operated pressure switch, range 1 to 20 psig (.07 to 1.4 bar), SPDT mercury switch | ||
MODEL | AP APS APF APH APW APWT |
General Purpose Enclosure, NEMA 1 No Enclosure Factory Mutual Approved (153-37, 7021-153-37 only) Explosion-proof Enclosure, NEMA 7, 9 Weatherproof Enclosure with Drain (NEMA 2, 3R) Weatherproof Enclosure (NEMA 4) |
|||||
CONSTRUCTION | |
41 7021 8021 7041 8041 |
Mercury Switch, Plated Steel Pressure Port, Buna-N Diaphragm Mercury Switch, 316SS Pressure Port, Buna-N Diaphragm Snap Switch, Plated Steel Pressure Port, Buna-N Diaphragm (153, 804 only) Snap Switch, Plated Steel Pressure Port, Buna-N Diaphragm, 440V (153 only) Snap Switch, 316SS Pressure Port, PTFE Diaphragm (153, 804 only) Snap Switch, 316SS Pressure Port, PTFE Diaphragm, 440V (153 only) |
||||
CIRCUIT | 2 3 26 36 88 152 153 804 |
2 Circuit 3 Circuit 26 Circuit 36 Circuit 88 Circuit 152 Circuit 153 Circuit 804 Circuit |
|||||
RANGE | 33 36 37 39 |
-10 to 50” w.c. * 1 to 20 psig 1 to 30 psig 10-125 psig |
|||||
OPTIONS | ATR ATW STR STW PT BREATHER DRAIN JCT PRESET QS3 |
Aluminum Tag (Riveted) Aluminum Tag (Wired) Stainless Steel Tag (Riveted) Stainless Steel Tag (Wired) Paper Tag Breather * Drain Junction Box Preset and Pressure Check Set Point QS3 Control Certification |
**See Electrical Rating Chart below.
ELECTRICAL RATING MERCURY SWITCH
CODE | CIRCUIT SUFFIX NO. | AC CAPACITY | DC CAPACITY | HORSEPOWER | ||||
120V | 240V | 440V | 120V | 240V | AC | DC | ||
P | -2, -3 | 10A | 5A | 3A | 10A | 5A | 3/4 | 1/3 |
R | -26, -36 | 17A at 120/240/277 VAC, Resistive balance same as above. | ||||||
S | -153 | 4A | 2A | NA | 4A | 2A | 1/8 | NA |
T | -88, -89 | 0.5A | 0.25A | NA | 0.25A | 0.125A |
Write Your Own Review