Series 629HLP Differential Pressure Transmitter

Series 629HLP Differential Pressure Transmitter

Series MSX Pro Magnesense® Differential Pressure Transmitter

Series MSX Pro Magnesense® Differential Pressure Transmitter

Series MSX Magnesense® Differential Pressure Transmitter

Monitors Differential Pressure, Air Velocity and Volumetric Flow

The Series MSX Magnesense® Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense® II transmitter for use in building control applications. The MSX simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges are available in Pa, mm w.c., and in w.c. All pressure ranges can be configured in unidirectional or bidirectional modes, providing a total of 32 ranges. The MSX transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification.

NIST CALIBRATION available in Product Configurator.

Please see Series AT-MSX for ATEX/IECEx approved.



⚠WARNING: This product can expose you to Styrene a chemical known to the State of California to cause Cancer and Bisphenol A (BPA) a chemical known to the State of California to cause reproductive toxicity. Click Here.

Product Applications

    • Filter monitoring in air handler units
    • Building pressure in pharmaceutical/semiconductor clean rooms
    • Duct static pressure in commercial buildings
    • Air velocity/flow in VAV systems
 
 
Filter By
Grouped product items
Model Description Availability* Qty Price
MSX-U12-IN Differential pressure transmitter, universal (duct or wall) mount, universal current/volt outputs, uni-directional, range 2 (1, 2, 3, 5" wc). 1-3 days*
$137.30
MSX-U12-IN-LCD Differential pressure transmitter, universal (duct or wall) mount, universal current/volt outputs, uni-directional, range 2 (1, 2, 3, 5" wc) with LCD display. Less Than 1 Week*
$187.50
MSX-W10-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 0 (0.1, 0.15, 0.25, 0.5" wc). 1-3 days*
$111.30
MSX-W10-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 0 (0.1, 0.15, 0.25, 0.5" wc) with LCD display. 1-3 days*
$161.50
MSX-W10-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 0 (60, 75, 100, 125 Pa). 1-3 days*
$111.30
MSX-W11-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 1 (0.1, 0.25, 0.5, 1" wc). 1-3 days*
$111.30
MSX-W11-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 1 (0.1, 0.25, 0.5, 1" wc) with LCD display. 1-3 days*
$161.50
MSX-W11-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 1 (25, 100, 125, 250 Pa). 1-3 days*
$111.30
MSX-W12-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 2 (1, 2, 3, 5" wc). 1-3 days*
$111.30
MSX-W12-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 2 (1, 2, 3, 5" wc) with LCD display. 1-3 days*
$161.50
MSX-W12-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 Pa). 1-3 days*
$111.30
MSX-W12-PA-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 Pa), LCD display 1-3 days*
$161.50
MSX-W13-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 3 (10, 15, 25, 28" wc). 1-3 days*
$111.30
MSX-W13-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 3 (10, 15, 25, 28" wc) with LCD display. 1-3 days*
$161.50
MSX-W13-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, uni-directional, range 3 (3000, 4000, 5000, 7000 Pa). 1-3 days*
$111.30
MSX-W20-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 0 (0.1, 0.15, 0.25, 0.5" wc). 1-3 days*
$111.30
MSX-W20-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 0 (0.1, 0.15, 0.25, 0.5" wc) with LCD display. 1-3 days*
$161.50
MSX-W20-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 0 (60, 75, 100, 125 Pa). 1-3 days*
$111.30
MSX-W21-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 1 (0.1, 0.25, 0.5, 1" wc). 1-3 days*
$111.30
MSX-W22-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 2 (1, 2, 3, 5" wc). 1-3 days*
$111.30
MSX-W22-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 2 (1, 2, 3, 5" wc) with LCD display. 1-3 days*
$161.50
MSX-W22-PA Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 2 (600, 750, 1000, 1250 Pa). 1-3 days*
$111.30
MSX-W23-IN Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 3 (10, 15, 25, 28" wc). 1-3 days*
$111.30
MSX-W23-IN-LCD Differential pressure transmitter, wall mount, universal current/voltage outputs, bi-directional, range 3 (10, 15, 25, 28" wc), LCD display 1-3 days*
$161.50

Specifications

Service:
Air and non-combustible, compatible gases.
Wetted Materials:
Consult factory.
Accuracy:
±1% FSO.
Stability:
±1% FSO/year.
Temperature Limits:
-4 to 158°F (-20 to 70°C).
Pressure Limits:
Ranges 0 and 1: 3.6 psi (24.8 kPa) max operation, 6 psi (41.3 kPa) burst; Ranges 2, 3 and 4: 6 psi (41.3 kPa) max operation, 6 psi (41.3 kPa) burst.
Power Requirements:
10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire).
Output Signals:
4-20 mA (2-wire); 0-10 V or 0-5 V selectable (3-wire).
Response Time:
Instantaneous (default) or 3 s (selectable).
Zero and Span Adjustments:
Digital push-button.
Loop Resistance:
Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 k Ω.
Current Consumption:
21 mA max continuous.
Electrical Connections:
4-wire removable European style terminal block for 16 to 26 AWG.
Electrical Entry:
1/2" NPS thread.
Display (optional):
4 digit LCD.
Process Connections:
1/8", 3/16", 1/4", 5 mm, and 6 mm ID flexible tubing.
Enclosure Rating:
NEMA 4X (IP66), UL 2043 (Plenum), UL94 V-0.
Mounting Orientation:
Pressure sensor measurement unaffected by orientation.
Weight:
8.0 oz (230 g).
Compliance:
CE.

Features

  • Read LCD values easier with rotatable 180° display
  • Quick and easy wiring via the optional toolless terminal block
  • Add safety to variety of applications with UL94 V-0 and plenum ratings

Model Chart

MSX-XXX-X-OPT     MSX DIFFERENTIAL PRESSURE TRANSMITTER
    
          1ST SYMBOL (1ST X) MOUNTING
             W    WALL MOUNT
             U    UNIVERSAL (WALL OR DUCT)
             N    DIN MOUNT
             S    SQUARE HOUSING WALL MOUNT
             Y    SQUARE HOUSING UNIVERSAL (WALL OR DUCT)
             Z    SQUARE DIN MOUNT 
            
          2ND SYMBOL (2ND  X) DIRECTION
             1    UNI-DIRECTIONAL
             2    BI-DIRECTIONAL
            
          3RD SYMBOL (3RD  X) PRESSURE RANGE
             0    0.5 INWC, 125 PA, 12 MMWC
             1    1 INWC, 250 PA, 25 MMWC
             2    5 INWC, 1250 PA, 125MMWC
             3    28 INWC, 7000 PA, 700 MMWC
             4    15 INWC, 4000 PA, 400 MMWC 

          4TH SYMBOL (4TH  X) UNITS OF MEASURE
             IN   INCHES OF WATER COLUMN
             PA   PASCAL
             MM   MILLIMETERS OF WATER COLUMN
            
          OPT (OPTIONS) ADD ON OPTIONS
            -A481  STATIC TIPS AND TUBING KIT
            -COM   BACNET/MODBUS® COMMUNICATIONS
            -FC    FACTORY CALIBRATION CERTIFICATE
            -FP    FILTERED PICKUP WITH BARB
            -GLD   CABLE GLAND ACCESSORY
            -LCD   LIQUID CRYSTAL DISPLAY
            -NIST  NIST CALIBRATION CERTIFICATE
            -STX   STATIC TIPS
            -TT    TOOL-LESS TERMINAL BLOCK
            -WO    LCD COVER WITHOUT LCD DISPLAY

Questions

Question
We ordered a bunch of MS2-D103-LCD pressure transmitters last year and need to order (20) more this year. It looks like the MS2 is not an option any more and we need to go with a MSX series. We just want to confirm that a MSX-U13-IN-LCD is the same unit as the MS2-D103-LCD and that it is a Duct mount with probe.
Answer
Model number MSX-U13-IN-LCD would be perfect for duct applications to replace the MS2 unit you're currently using.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-155 Cable gland with 1/2" male NPT fitting 1-3 days*
$21.40
A-480 Plastic static pressure tip 1-3 days*
$2.15
A-481 Installer kit, (includes 2 static pressure tips and PVC tubing). 1-3 days*
$6.60
A-MSX-LCD Replacement LCD display for the MSX Series 1-3 days*
$52.10
A-MSX-ORING Replacement o-ring for the MSX Series 1-2 Weeks*
$10.00