Series MSX Magnesense® Differential Pressure Transmitter

Series MSX Magnesense® Differential Pressure Transmitter

Series AT-MS ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter

Series AT-MS ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter

Series MSX Pro Magnesense® Differential Pressure Transmitter

Monitors Differential Pressure, Air Velocity and Volumetric Flow

The Series MSX Pro Magnesense® Differential Pressure Transmitter is the professional differential pressure transmitter meeting stringent industry standards with innovative global product design. The device has exceptional stability for use in critical building performance applications with the popular versatility of our original Series MS2 Magnesense® II transmitter. The MSX Pro simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges of Pa, mm w.c., and in w.c. are available per device. All pressure ranges can be configured in unidirectional or bidirectional modes providing a total of 32 ranges. The MSX Pro transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability to calculate flow. Dual voltage and milliamp output signals can be used to provide control and equipment output signal verification.

NIST CALIBRATION available in Product Configurator.

Product Applications

  • High performance building applications for critical environments
  • Filter monitoring in air handler units
  • Building pressure in pharmaceutical/semiconductor clean rooms
  • Duct static pressure in commercial and specialized buildings
  • Air velocity/flow in VAV systems
Starting at $177.85
Filter By
Grouped product items
Model Description Availability* Qty Price
MSXP-W10-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 0 (60, 75, 100, 125 PA). 1-3 days*
$177.85
MSXP-W10-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 0 (60, 75, 100, 125 PA) with LCD display. 1-3 days*
$228.05
MSXP-W11-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 1 (100, 150, 160, 250 PA). 1-3 days*
$177.85
MSXP-W12-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 PA). 1-3 days*
$177.85
MSXP-W12-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 PA) with LCD display. 1-3 days*
$228.05
MSXP-W13-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 3 (3000, 4000, 5000, 7000 PA). 1-3 days*
$177.85
MSXP-W13-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, uni-directional, range 3 (3000, 4000, 5000, 7000 PA) with LCD display. 1-3 days*
$228.05
MSXP-W20-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 0 (60, 75, 100, 125 PA) with LCD display. 1-3 days*
$228.05
MSXP-W23-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 3 (3000, 4000, 5000, 7000 PA) with LCD display. 1-3 days*
$228.05
MSXP-W20-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 0 (60, 75, 100, 125 PA). 1-3 days*
$177.85
MSXP-U12-PA-LCD Differential pressure transmitter pro unit, universal (duct or wall) mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 PA)with LCD display. Less Than 1 Week*
$254.05
MSXP-U12-PA Differential pressure transmitter pro unit, Universal (duct or wall) mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 PA). 1-3 days*
$203.85
MSXP-W22-PA-LCD Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 2 (600, 750, 1000, 1250 PA) with LCD display. 1-3 days*
$228.05
MSXP-W22-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 2 (600, 750, 1000, 1250 PA). Less Than 1 Week*
$177.85
MSXP-W23-PA Differential pressure transmitter pro unit, wall mount, universal current/voltage outputs, bi-directional, range 3 (3000, 4000, 5000, 7000 PA). Less Than 1 Week*
$177.85

Specifications

Service:
Air and non-combustible, compatible gases.
Wetted Materials:
Consult factory.
Accuracy:
±.5% FSO for all ranges except unidirectional .5 in. @ ±1% FSO.
Stability:
±1% FSO/year.
Temperature Limits:
-4 to 158°F (-20 to 70°C).
Pressure Limits:
Ranges 0 and 1: 3.6 psi max operation, 6 psi burst; Ranges 2 and 3: 6 psi max operation, 6 psi burst.
Power Requirements:
10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire).
Output Signals:
Output Signals: 4-20 mA (2-wire); 0-10 V or 0-5 V selectable (3-wire).
Response Time:
Instantaneous (default) or 3 s (selectable).
Zero and Span Adjustments:
Digital push-button.
Loop Resistance:
Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 k Ω.
Current Consumption:
21 mA max continuous.
Electrical Connections:
4-wire removable European style terminal block for 16 to 26 AWG.
Electrical Entry:
1/2" NPS thread. Cable gland included.
Display (optional):
4 digit LCD.
Process Connections:
1/8", 3/16", 1/4", 5 mm, and 6 mm ID flexible tubing.
Enclosure Rating:
NEMA 4X (IP66), UL 2043 (Plenum), UL94 V-0.
Mounting Orientation:
Pressure sensor measurement unaffected by orientation.
Weight:
8.0 oz (230 g).
Compliance:
CE.

Features

  • Easily access the unit’s wiring via the flip-lid housing
  • Eliminates accidental damage to the unit during installation with the products innovative design shielding the electronics underneath the PCB
  • Added security and protection from the tamper-resistant cover
  • Protection from liquids and moisture near the cable egress point with the included liquid tight cable gland fitting
  • Reduce installation time with quick and easy wiring via the included a toolless terminal block
  • Add safety to variety of applications that need to meet municipal and building code standards with UL94 V-0 and plenum ratings

Model Chart

MSXP-XXX-X-OPT    MSX PRO DIFFERENTIAL PRESSURE XMTR
     
          1ST SYMBOL (1ST X) MOUNTING
             W    WALL MOUNT
             U    UNIVERSAL (WALL OR DUCT)
             N    DIN MOUNT
             
          2ND SYMBOL (2ND  X) DIRECTION
             1    UNI-DIRECTIONAL
             2    BI-DIRECTIONAL
             
          3RD SYMBOL (3RD  X) PRESSURE RANGE
             0    0.5 INWC, 125 PA, 12 MMWC
             1    1 INWC, 250 PA, 25 MMWC
             2    5 INWC, 1250 PA, 125MMWC
             3    28 INWC, 7000 PA, 700 MMWC

          4TH SYMBOL (4TH  X) UNITS OF MEASURE
             IN   INCHES OF WATER COLUMN
             PA   PASCAL
             MM   MILLIMETERS OF WATER COLUMN
             
          OPT (OPTIONS) ADD ON OPTIONS
            -A481  STATIC TIPS AND TUBING KIT
            -COM   BACNET/MODBUS® COMMUNICATIONS
            -FC    FACTORY CALIBRATION CERTIFICATE
            -FP    FILTERED PICKUP WITH BARB
            -LCD   LIQUID CRYSTAL DISPLAY
            -NIST  NIST CALIBRATION CERTIFICATE
            -STA   STATIC TIPS
            -WO    LCD COVER WITHOUT LCD DISPLAY
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-155 Cable gland with 1/2" male NPT fitting 1-3 days*
$21.40
A-480 Plastic static pressure tip 1-3 days*
$2.15
A-481 Installer kit, (includes 2 static pressure tips and PVC tubing). 1-3 days*
$6.60
A-MSXP-LCD Replacement LCD display for MSXP 1-2 Weeks*
$52.10