Series TABKIT Test, Adjust, and Balance Kit
A Complete Balancing Technician Solution
The Series TABKIT Test, Adjust, and Balance Kit combines all essential air, water, temperature, humidity, and electrical test instruments are included in this kit, creating the ultimate air and water balancing solution. The Series TABKIT has everything a balancing technician needs in a single case. A certificate of NIST calibration is included for each instrument inside the kit, ensuring accurate, durable, repeatable, and reliable measurements every time. When the products need to be recalibrated, save time by sending everything back to Dwyer. Our lab is able to service all equipment within the kit, and ensure they’re as accurate as the day you originally received them.
Complete Kit Includes:
- Model 160G Averaging Air Flow Grid
- Model DP3 Bluetooth-Enabled Wireless Differential Pressure Module
- Model AP3 Bluetooth-Enabled Wireless Thermo-Anemometer Probe
- Model RP3 Bluetooth-Enabled Wireless Thermo-Hygrometer Probe
- Model VP3 Bluetooth-Enabled Wireless 100 mm Vane Thermo-Anemometer Probe
- Model TAC-L Portable Digital Tachometer
- Model CM-1 Digital Clamp Meter
- Series 490W Wireless Hydronic Differential Pressure Manometer
- Model 160F 18" Straight Stainless Steel Pitot Tube
- Model 160-18 18" Stainless Steel Pitot Tube
- Two Model A-303 Static Pressure Tips with Magnetic Mounting
- Cooper-Atkins Model TM99A Thermistor Temperature Instrument
- Cooper-Atkins Model 1075 General Purpose Puncture Probe
- Hard Case
Product Applications
- Building balancing
- Building commissioning
- Testing HVAC equipment performance
Starting at $7,865.00
Specifications
- AIR
- Series DP3
- Accuracy*:
- ±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
- Pressure Limits:
- ±10 in w.c. (±2.5 kPa).
- Temperature Limits:
- Operating: -4 to
140°F (-20 to 60°C); Storage: -40 to 185°F
(-40 to 85°C).
- Model AP3
- Range:
- Air velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric air: 999,999 in selected flow units; Temperature: -20 to 212°F (-29 to 100°C).
- Accuracy:
- Air velocity*: ±3% FS within
temperature range of 40 to 90°F (4 to
32°C) -TAB option: 50 to 3900 FPM (0.25
to 20 m/s); Temperature: ±0.5°F (±0.28°C).
- Model VP3
- Range:
- Air velocity: 40 to 5000 FPM (0.2 to 25 m/s); Volumetric air: 999,999 in selected flow units; Temperature: -20 to 212°F (-29 to 100°C); Relative humidity: 0 to 100% RH.
- Accuracy:
- Air velocity*: 0.25 to 10
m/s: ±1.5% of reading ±20 FPM (±0.1
m/s); 10 to 20 m/s: 1.5% of reading
±40 FPM (±0.2 m/s); 20 to 25 m/s:
±1.5% of reading ±60 FPM (±0.3 m/s);
Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C);
Relative humidity: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% RH and 90 to 100%). - Resolution:
- 1 FPM (0.001 m/s).
- TEMPERATURE
- TM99A and 1075
- Range:
- 0 to 200°F (-20 to 100°C).
- Accuracy*:
- ±0.5% of reading + 2.0°F (±0.5% of reading + 1.0°C).
- Resolution:
- 0.1°F (0.1°C).
- HUMIDITY
- Model RP3
- Range:
- RH: 0 to 100% (noncondensing); Temperature: -22 to 140°F (-30 to 60°C).
- Accuracy:
- RH*: ±2% @ 25°C (10 to
90% RH); ±4% (0 to 10, 90 to 100% RH);
Temperature: ±0.54°F @ 77°F (±0.3°C).
- ELECTRICAL
- Model CM-1
- AC Voltage:
- 0.1-600 V ± (1.0% + 5 dgt).
- DC Voltage:
- 0.1-600 V ± (1.0% + 3 dgt).
- AC Current:
- 0.1-400 A ± (2.0% + 10 dgt).
- Resistance:
- 0.1-400 Ω ± (1.0% + 5 dgt).
- ROTATION
- Model TAC-L
- Range:
- Non-contact (RPM): 2.5 to 99,999 RPM; Contact (RPM): 0.5 to 19,999 RPM; Surface speed (m/min): 0.05 to 19,999 m/min.
- Resolution:
- Non-contact* (RPM): 0.1
RPM (2.5 to 999.9 RPM), 1 RPM (1000
to 19,000 RPM); Surface speed (m/min):
0.01 m/min (0.05 to 99.99 m/min), 0.1 m/
min (100.0 to 1999.9 m/min).
- HYDRONIC
- A-490W-6
- Range:
- 0.4 to 200 psi, 3 to 1400 kPa.
0.4 to 75 psi, 3 to 500 kPa. - Accuracy:
- 2% of reading ±1 psi, 2% of reading ±7 kPa.
2% of reading ±0.5 psi, 2% of reading ±3.5 kPa. - Resolution:
- 0.1 psi, 1.0 kPa.
0.01 psi, 0.1 kPa. - *NIST calibrated.
Features
- Everything a balancing technician needs in a single case
- Best in class low flow velocity readings
- Repeatable measurements
Approvals
Write Your Own Review
Model | Description | Availability* | Price | |
---|---|---|---|---|
A-303 | Portable static pressure tip, for 3/16" ID rubber or plastic tubing with 4" insertion. | 1-3 days* |
$12.50 |
|
160F | Straight stainless steel pitot tube, 18" | 1-3 days* |
$259.00 |
|
160G | Averaging air flow grid. | 1-3 days* |
$312.00 |
|
160-18 | Stainless steel Pitot tube, 5/16" dia., 18-5/8" insertion length. | 1-3 days* |
$130.00 |
|
490W-6-HKIT-NIST | Hydronic differential pressure manometer with wireless sensors, 0-50 psid & 0-200 psid, 1/4" male NPT (2 of each range) with NIST calibration | Less Than 1 Week* |
$3,695.00 |
|
AP3-NIST | Wireless Thermo-Anemometer air velocity & temperature probe, 8" insertion length for use with the Model UHH Universal Handheld device and the Mobile Meter® Software application with NIST calibration. | 2-3 Weeks* |
$805.00 |
|
DP3-NIST | Wireless differential pressure manometer, high accuracy with NIST Calibration. | 2-3 Weeks* |
$855.00 |
|
RP3-NIST | Wireless Thermo-Hygrometer probe, 8" insertion length for use with the Model UHH Universal Handheld device and the Mobile Meter® software application with NIST calibration. | 2-3 Weeks* |
$708.00 |