Series 673 Pressure Transmitter

Series 673 Pressure Transmitter

Series 679 Weatherproof Pressure Transmitter

Series 679 Weatherproof Pressure Transmitter

Series 636 Fixed Range Pressure Transmitter

Stainless Steel, Explosion-proof, Accuracy ±0.30%, 4 to 20 mA or 1 to 5 VDC Signal

The Series 636 Fixed Range Pressure Transmitter is a low cost, fixed range, stainless steel transmitter with ±0.30% accuracy. It is designed to continuously measure pressure for years in even the toughest environmental and media conditions. Transmitters are explosion-proof, (FM approved) and meet NACE standards for off-shore applications.

Calibration Option available under Accessories.

Product Applications

  • Off-shore
  • Process applications
Starting at $982.45
Grouped product items
Model Description Availability* Qty Price
636-0 Fixed range pressure transmitter, range 0-15 psi (0-1 bar). 1-3 days*
$985.30
636-1 Fixed range pressure transmitter, range 0-30 psi (0-2 bar). Call for Details*
$982.45
636-2 Fixed range pressure transmitter, range 0-100 psi (0-7 bar). 1-3 days*
$982.45
636-3 Fixed range pressure transmitter, range 0-300 psi (0-20 bar). 1-3 days*
$982.45
636-4 Fixed range pressure transmitter, range 0-1000 psi. Call for Details*
$1,070.20
636-6 Fixed range pressure transmitter, range 0-5000 psi. Call for Details*
$1,070.20
636-7 Fixed range pressure transmitter, range 0-60 psi. Call for Details*
$1,070.20

Specifications

Service:
Liquid, gas or vapor.
Wetted Materials:
316 L SS.
Fill Fluid:
DC 200 Silicone (standard).
Accuracy:
±0.30% of calibrated span including linearity hysteresis and repeatability (BFSL) at 25°C (77°F) and 12 VDC excitation.
Stability:
±0.5% of upper range limit for six months.
Temperature Limits:
Electronics (ambient): -40 to 140°F (-40 to 60°C); Process interface: -40 to 212°F (-40 to 100°C).
Pressure Limits:
300% upper range limit.
Compensated Temperature Range:
-20 to 180°F (-29 to 82°C).
Thermal Effect (includes zero and span):
Between -20 and 180°F (-29 and 82°C). ±2.0% per 50°F (28°C).
Power Requirements:
12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse polarity protection.
Output Signal:
4 to 20 mA DC, limited to 30 mA DC (636), 1 to 5 VDC (636LP).
Zero and Span Adjustments:
Null: 4.0 mA ±2% span (636), 1 VDC ±1% span (636LP); Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP).
Loop Resistance:
900 Ω max. @ 30 V.
Electrical Connection:
3/4" female NPT 24" (61 cm), 22 AWG.
Process Connection:
1/2" female NPT.
Enclosure Rating:
NEMA 4 (IP56).
Weight:
0.83 lb (374 g).
Compliance:
CSA, FM. FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III.

Features

  • Long service life and lower cost to maintain reduces total cost of ownership
  • Explosion-proof housing for use in applications where protection of process and personnel is needed

Product Literature

Manuals

Catalog Pages

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price