Representative image displayed of IEFB-SN-CNDR10LCDCOM|Actual product may vary

IEFB-SN-CNDR10LCDCOM

Representative image displayed of IEFB-FB-PGR10LCDCOM|Actual product may vary

IEFB-FB-PGR10LCDCOM

Series IEFB Insertion Thermal Energy Meter

Field Adjustable, BACnet/Modbus® Outputs

The Series IEFB is a field-adjustable insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption. The high accuracy IEFB is adjustable to fit pipe sizes from 4 to 10" (100 to 250 mm), while the standard accuracy IEFB fits pipe sizes 4 to 36" (100 to 900 mm). The IEFB incorporates a temperature meter and a calculator into a single unit. The LCD display provides clear readings of the meter’s values, including temperature and energy consumption, making it ideal for installation on chillers, boilers, and other heating and cooling applications. The high measuring accuracy and long lifetime keeps annual operating costs at a minimum. In addition, it offers several output options, including selectable BACnet MS/TP or Modbus® RTU communications protocol over 2-wire RS-485 and standard analog, frequency, and alarm outputs.

Product Applications

  • Monitoring chiller cooling output performance
  • Industrial boiler heating performance
  • Energy efficiency monitoring
  • Optimization of heat energy performance
  • Commercial and residential heat energy consumption and metering
  • District heating and cooling monitoring
  • Energy cost allocation monitoring
Starting at $4,773.00
Filter By
Grouped product items
Model Description Availability* Qty Price
IEFB-FB-PG-T10-LCD Insertion Electromagnetic energy system with LCD display, 4" (100 MM) pipe, 1% of reading, BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors, LCD display 1-2 Weeks*
$5,304.00
IEFB-FB-PGR10LCDCOM Insertion Electromagnetic energy system with LCD display, 4" (100 MM) pipe, 1% of reading, BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 1-2 Weeks*
$5,972.00
IEFB-FN-CNDR10LCDCOM Insertion Electromagnetic energy system with LCD display, 8" (200 MM) pipe, 1% of reading, NPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 1-2 Weeks*
$5,972.00
IEFB-HB-PG-R10-LCD Insertion Electromagnetic energy system with LCD display, high accuracy 4-10" (100-250 MM) pipe; 1% of reading, 1" Male BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells 2-3 Weeks*
$6,984.00
IEFB-HB-PG-T10-LCD Insertion Electromagnetic energy system with LCD display, high accuracy 4-10" (100-250 MM) pipe; 1% of reading, 1" Male BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors 2-3 Weeks*
$6,828.00
IEFB-HB-PGR10LCDCOM Insertion Electromagnetic energy system with LCD display, high accuracy 4-10" (100-250 MM) pipe; 1% of reading, 1" Male BSPT process connections, PG 16 gland, (2) 10´ (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 2-3 Weeks*
$7,496.00
IEFB-HB-PGT10LCDCOM Insertion Electromagnetic energy system with LCD display, high accuracy 4-10" (100-250 MM) pipe; 1% of reading, 1" Male BSPT process connections, PG 16 gland, (2) 10´ (3 M) PT temperature sensors, BACnet/Modbus® communication output 2-3 Weeks*
$7,340.00
IEFB-HN-CND-R10-LCD Insertion Electromagnetic energy system with LCD display, high accuracy 4 to 10" (100-250 MM) pipe, 1% of reading, 1" male NPT process connection, NPT process connections, conduit connections, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells 2-3 Weeks*
$6,984.00
IEFB-HN-CND-T10-LCD Insertion Electromagnetic energy system with LCD display, high accuracy 4 to 10" (100-250 MM) pipe, 1% of reading, 1" male NPT process connection, NPT process connections, conduit connection, (2) 10' (3 M) PT temperature sensors 2-3 Weeks*
$6,828.00
IEFB-HN-CNDR10LCDCOM Insertion Electromagnetic energy system with LCD display, high accuracy 4 to 10" (100-250 MM) pipe, 1% of reading, 1" male NPT process connection, NPT process connections, conduit connection, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 2-3 Weeks*
$7,496.00
IEFB-HN-CNDT10LCDCOM Insertion Electromagnetic energy system with LCD display, high accuracy 4-10" (100-250 MM) pipe, 1% of reading, 1" male NPT process connection, NPT process connections, conduit connection, (2) 10' (3 M) PT temperature sensors, BACnet/Modbus® communication output 2-3 Weeks*
$7,340.00
IEFB-IB-PG-T10-LCD Insertion Electromagnetic energy system with LCD display, 6" (150 MM) pipe, 1% of reading, BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors 1-2 Weeks*
$5,304.00
IEFB-IB-PGR10LCDCOM Insertion Electromagnetic energy system with LCD display, 6" (150 MM) pipe, 1% of reading, BSPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 1-2 Weeks*
$5,972.00
IEFB-IN-CNDR10LCDCOM Insertion Electromagnetic energy system with LCD display, 6" (150 MM) pipe, 1% of reading, NPT process connections, PG 16 gland, (2) 10' (3 M) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output 1-2 Weeks*
$5,972.00
IEFB-LB-PGR10LCDCOM Insertion Electromagnetic energy system, 4 to 10" (100 to 250MM) pipe, 1% FS, 1" male BSPT process connections, PG 16 gland without cable, (2) 10' (3 m) PT temperature sensors with hot-tap thermowells, BACnet or Modbus® communications protocol (display selectable), LCD display 1-2 Weeks*
$5,285.00
IEFB-LN-CND-R10-LCD Insertion Electromagnetic energy system, 4 to 10" (100 to 250MM) pipe, 1% FS, 1" male NPT process connections, 1/2" female NPT, (2) 10' (3 m) PT temperature sensors with hot-tap thermowells, LCD display 1-2 Weeks*
$4,773.00
IEFB-LN-CNDR10LCDCOM Insertion Electromagnetic energy system, 4 to 10" (100 to 250MM) pipe, 1% FS, 1" male NPT process connections, 1/2" female NPT, (2) 10' (3 m) PT temperature sensors with hot-tap thermowells, BACnet or Modbus#8482; communications protocol (display selectable), LCD display 1-2 Weeks*
$5,285.00
IEFB-SB-PGR10LCDCOM Insertion Electromagnetic energy system, 4 to 36" (100-900 MM) pipe, 1% FS, 1" male BSPT process connections, PG 16 gland without cable, BACnet or Modbus® communications protocol (display selectable), LCD display 1-2 Weeks*
$5,441.00
IEFB-SN-CNDR10LCDCOM Insertion Electromagnetic energy system, 4 to 36" (100-900 MM) pipe, 1% FS, 1" male NPT process connections, 1/2" female NPT, (2) 10' (3 m) PT temperature sensors with hot-tap thermowells, BACnet/Modbus® communication output, LCD display 1-2 Weeks*
$5,441.00