Series TUF Ultrasonic Energy Meter

Series TUF Ultrasonic Energy Meter

Series RM Rate-Master® Polycarbonate Flowmeter

Series RM Rate-Master® Polycarbonate Flowmeter

Series SFI-800 Sight Flow Indicator/Transmitter

Low Cost, Optional Output for Flow Rate and Totalization, UV Stabilized Polycarbonate Model

The Series SFI-800 Sight Flow Indicators & Transmitters are a low cost, durable rotor style flow indicator with optional Hall Effect magnetic output packages to combine visual confirmation of flow with optional remote flow monitoring. There are three output sensors available, the A-711 offering two pulsed voltage signals proportional to flow rate, the A-712 which outputs a linear 1 to 10 VDC signal proportional to flow rate, and the A-713 which offers two programmable open collector switch outputs.
The Model A-711 is a unique and patent pending sensor that outputs two pulsed voltage signals with one providing a 5 VDC pulse and the other a pulse of the input supply voltage used, ranging from 8 to 18 VDC.
The Model A-712 is a sensor that outputs a linear 1 to 10 VDC signal proportional to flow rate.
The Model A-713 is a sensor with two programmable open collector switch outputs with one output closed above the set point and the other output closed below the set point ideal for low flow or high flow indication.

Product Applications

  • Cooling and lubrication circuits
  • HVAC systems
  • Aggressive chemical metering
  • Batching systems
Starting at $105.05
Filter By
Grouped product items
Model Description Availability* Qty Price
SFI-800-1/2 Polysulfone sight flow indicator only, range 2-20 GPM (7.6-75.5 LPM), 1/2" female NPT. 1-3 days*
$105.05
SFI-800-1/2-A711 Polysulfone sight flow indicator with A-711 sensor, range 2-20 GPM (7.6-75.5 LPM), 1/2" female NPT. 1-2 Weeks*
$242.35
SFI-800-3/4 Polysulfone sight flow indicator only, range 3-35 GPM (11.4-132.5 LPM), 3/4" female NPT. 1-3 days*
$105.05
SFI-800-3/4-A711 Polysulfone sight flow indicator with A-711 sensor, range 3-35 GPM (11.4-132.5 LPM), 3/4" female NPT. 1-3 days*
$242.35
SFI-801-1/2 Polycarbonate sight flow indicator only, range 2-20 GPM (7.6-75.5 LPM), 1/2" female NPT. 1-3 days*
$105.05
SFI-801-1/2-A711 Polycarbonate sight flow indicator with A-711 sensor, range 2-20 GPM (7.6-75.5 LPM), 1/2" female NPT. 1-2 Weeks*
$242.35
SFI-801-3/4 Polycarbonate sight flow indicator only, range 3-35 GPM (11.4-132.5 LPM), 3/4" female NPT. 1-3 days*
$105.05
SFI-801-3/4-A711 Polycarbonate sight flow indicator with A-711 sensor, range 3-35 GPM (11.4-132.5 LPM), 3/4" female NPT. 1-2 Weeks*
$242.35

Specifications

Service:
Compatible fluids.
Wetted Materials:
Body: SFI-800: Polysulfone; SFI-801: UV stabilized polycarbonate; Window: SFI-800: Polysulfone; SFI-801: UV stabilized polycarbonate; Rotor: SFI-800: White polysulfone; SFI-801: Red UV stabilized PBT; Rotor Pin: 316 SS; Thrust washers: 300 Series SS; O-Ring: SFI-800: Fluoroelastomer (NSF Grade); SFI-801: Buna-N.
Temperature Limits:
SFI-800: -20 to 212°F (-29 to 100°C); SFI-801: -20 to 130°F (-29 to 55°C).
Pressure Limits:
SFI-800: 150 psi (10.34 bar); SFI-801: 125 psi (8.62 bar).
Viscosity Maximum:
200 SSU.
Weight:
SFI-800: 3.35 oz (95 g); SFI-800-A-711: 5.0 oz (142 g).
Agency Approval:
CE.

ELECTRICAL SPECIFICATIONS (for A-711 Option Only):
Temperature Limits:
-20 to 212°F (-29 to 100°C).
Power Requirements:
8 to 28 VDC.
Output Signal:
White lead: 5 VDC. Green lead: 8 to 28 VDC equal to supply voltage. Pulsed output with frequency rate proportional to flow rate.
Accuracy:
±5% FS.
Frequency Output Range:
0 to 100 Hz.
Electrical Connections:
Black lead: Ground; White lead: 5 VDC out pulse; Green lead: 8 to 28 VDC out pulse; Red lead: 8 to 28 VDC supply.

ELECTRICAL SPECIFICATIONS (for A-712 Option Only):
Temperature Limits:
-20 to 212°F (-29 to 100°C).
Power Requirements:
15 to 28 VDC.
Output Signal:
White lead: 1 to 10 VDC.
Accuracy:
±5% of FS.
Electrical Termination:
Black lead: Ground; Red lead: 15 to 28 VDC input; White lead: 1 to 10 VDC output.

ELECTRICAL SPECIFICATIONS (for A-713 Option Only):
Temperature Limits:
-20 to 212°F (-29 to 100°C).
Power Requirements:
8 to 28 VDC.
Output Signal:
White lead: Normally open switch; Green lead: Normally closed switch. Both open collector, 100 mA max, 28 VDC max.
Electrical Connections:
Black lead: Ground; White lead: Normally open; Green lead: Normally closed; Red lead: 8 to 28 VDC.

Features

  • Constructed of clear plastic enabling 360° viewing of the rotor for easy flow indication
  • SFI-800 models are constructed of Polysulfone with excellent chemical compatibility, high pressure and temperature ratings, and all wetted materials are FDA/NSF ratable for potable water applications
  • SFI-801 models are constructed of UV stabilized Polycarbonate making them ideal for outdoor applications and easy view bright red impeller
  • All three output packages cam be installed or replaced in the field without any tools and without removing the body from the process line
  • Units are weather-tight for outdoor or wash-down area use
  • A-713 features a user-friendly set point button which is set at the desired flow rate with red LED indication of switch status

Product Literature

Manuals

Catalog Pages

Approvals

Model Chart

EXAMPLE SFI 800 1/2 A711 Series SFI-800-1/2-A711 Sight Flow Indicator/Transmitter, polysulfone body, 1/2" NPT ports, 2-20 GPM, with 5 VDC/8-28 VDC frequency output transmitter.
SERIES SFI       Sight Flow Indicator/Transmitter
BODY MATERIAL   800
801
    Polysulfone
Polycarbonate
SIZE     1/2
3/4
  1/2" NPT Ports, 2-20 GPM (7.6-75.5 LPM)
3/4" NPT Ports, 3-35 GPM (11.4-132.5 LPM)
OPTIONS       A711
A712
A713
LF
5 VDC/8-28 VDC Frequency Output Transmitter
1-10 VDC Voltage Output Transmitter
Switch Open Collector Output
Low Flow Restrictor (only with 1/2" Ports)

Questions

Question
What is the current consumption or power consumption for the SFI-800-1/2-A712?
Answer
The max current draw is 34mA.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price