Series CDTA Communicating Carbon Dioxide Detector

Series CDTA Communicating Carbon Dioxide Detector

Series CDWP Carbon Dioxide Transmitter

Series CDWP Carbon Dioxide Transmitter

Series CDTV Carbon Dioxide/Volatile Organic Compound Transmitters

Simultaneously Outputs Both CO2 / VOC

The Series CDTV Carbon Dioxide/Volatile Organic Compound (VOC) Transmitter reduces energy cost in buildings by lowering the amount of conditioned air based on the occupancy of the space. By sensing both CO2 and VOC, the transmitter can detect fumes that may need to be exhausted during lower occupancy periods.

For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.

Product Applications

  • HVAC applications in hospitals, schools, and commercial buildings
  • Demand control ventilation
  • Odor control
  • Waiting rooms or other spaces that may be occupied 24 hours a day
Starting at $418.10
Grouped product items
Model Description Availability* Qty Price
CDTV-2D404 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, no temperature Less Than 1 Week*
$462.30
CDTV-2D4A4 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, 10K Ohm Type III temperature sensor Less Than 1 Week*
$469.35
CDTV-2D4B4 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, 10K Ohm Type II temperature sensor Less Than 1 Week*
$469.35
CDTV-2D4D4 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, PT100 Ohm RTD temperature sensor Less Than 1 Week*
$470.50
CDTV-2D4E4 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, PT1K Ohm RTD temperature sensor Less Than 1 Week*
$470.50
CDTV-2D4F4 Duct VOC & CO2 transmitter, universal analog outputs, 2000PPM CO2, 20K Ohm temperature sensor Less Than 1 Week*
$469.35
CDTV-2N404 Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2 1-3 days*
$418.10
CDTV-2N404-LCD Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2 with LCD display 1-2 Weeks*
$464.90
CDTV-2N4A4 Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2, 10K Ohm Type III temperature sensor 1-2 Weeks*
$425.15
CDTV-2N4A4-LCD Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2, 10K Ohm Type III temperature sensor with LCD display 1-2 Weeks*
$471.95
CDTV-2N4B4 Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2, 10K Ohm Type II temperature sensor 1-2 Weeks*
$425.15
CDTV-2N4B4-LCD Wall Voc & CO2 transmitter, universal analog outputs, 2000 ppm CO2, 10K Ohm Type II temperature sensor with LCD display 1-2 Weeks*
$471.95

Specifications

Range:
CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); VOC: 0 to 2000 ppm CO2 equivalent.
Accuracy:
CO2: ±40 ppm ±3% of reading.
Temperature Dependence:
±8 ppm / °C at 1100 ppm.
Non-Linearity:
CO2: 16 ppm.
Pressure Dependence:
CO2: 0.13% of reading per mm of Hg.
Response Time:
CO2: 2 minutes for 99% step change; VOC: 5 minutes.
Temperature Limits:
32 to 122°F (0 to 50°C).
Duct Air Velocity Range:
0-4000 FPM (20.32 m/s).
Power Requirements:
16 to 35 VDC / 19 to 28 VAC.
Power Consumption:
Average: 2 watts; Peak: 3.75 watts.
Sensor:
CO2: Single-beam, dual-wavelength NDIR; VOC: MEMS metal oxide semiconductor.
Output:
Current: 0 to 20 mA, 4 to 20 mA, 0 to 10 mA, or 2 to 10 mA (depending on selection jumper, max 500 O); Voltage: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, or 1 to 5 VDC (depending on selection jumper, min 500 O); Relay: SPST NO 2A @ 30 VDC.
Weight:
5.6 oz (158.8 g).
Enclosure Rating:
Duct mount: NEMA 4X (IP66) for housing only; Wall mount: IP20.
Compliance:
CE.

Features

  • Combination VOC and CO2 outputs reduce labor and material costs
  • Single beam dual wavelength NDIR CO2 sensor allows for use in spaces that may be occupied 24 hours a day
  • VOC output is correlated to be equivalent to CO2 measurements
  • Ventilate using ASHRE’s occupancy-based VRP Algorithm

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Model Chart

EXAMPLECDTV2D404RLYSeries CDTV-2D404-RLY, Carbon Dioxide VOC Transmitter, gas concentration range 2000 ppm, duct mount, carbon dioxide output 0-5 VDC/0-10VDC/4-20mA, relay output
SERIESCDTV      Carbon Dioxide VOC Transmitter
GAS CONCENTRATION RANGE 2
5
     2000 ppm
5000 ppm
MOUNTING CONFIGURATION  D
N
    Duct Mount
North American Style Wall Mount
CARBON DIOXIDE OUTPUT   4   0-5 VDC/0-10 VDC/4-20mA
TEMPERATURE OUTPUT    0
A
B
C
D
E
F
  NONE                       
10K Ohm Type 3 NTC Thermistor
10K Ohm Type 2 NTC Thermistor
3K Ohm NTC Thermistor
PT100 Ohm RTD               
PT1000 Ohm RTD              
20K Ohm NTC Thermistor
VOC OUTPUT     4 0-5 VDC/0-10 VDC/4-20 mA
OPTIONS      COC
FC
LCD
RLY
Certificate of Calibration
Factory Calibration Certificate
LCD Display (not available with Duct Mount)
Relay Output
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-449A Remote display with push buttons and mini USB. (Necessary for models with –NBC option) 1-3 days*
$134.15
A-449 Remote display with mini USB display 1-3 days*
$68.60
A-CDT-KIT Accessory kit including terminal block and power supply. 1-2 Weeks*
$55.15
GCK-200CO-2000CO2 Gas Calibration Kit (GROUND SHIPMENTS ONLY) 1-3 days*
$726.55