Series GSTA Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

Series GSTA Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

Series GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

Series GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

Series CMT200 Carbon Monoxide Transmitter

Current/Voltage Selectable Output, 200 PPM Range

The Series CMT200 Carbon Monoxide Transmitter provides a field selectable current or voltage output that is proportional to the gas concentration in underground parking garages, vehicle maintenance facilities, or mechanical rooms. A field replaceable, electrochemical sensor provides accurate readings for up to 4 years with proper calibration. Field calibration can be done by using Model GCK-200CO-2000CO2 calibration gas, Model A-507A calibration adapter, and the on board span and zero potentiometers.

Product Applications

  • Garage ventilation
  • Mechanical room monitoring
Starting at $163.05
Filter By
Grouped product items
Model Description Availability* Qty Price
CMT200 Carbon Monoxide Transmitter, 0 to 200 PPM CO, 4 to 20 mA/2 to 10 VDC outputs. 1-3 days*
$163.05
CMT200-FC Carbon monoxide transmitter, 0-200 PPM CO, 4-20 mA/2-10 VDC outputs, includes factory calibration certificate 3-4 Weeks*
$202.80
CMT200-R Carbon Monoxide Transmitter, 0 to 200 PPM CO, 4 to 20 mA/2 to 10 VDC outputs, rectangular enclosure 1-3 days*
$169.25
CMT200-R-FC Carbon monoxide transmitter, 0-200 PPM CO, 4-20 mA/2-10 VDC outputs, rectangular enclosure, includes factory calibration certificate 3-4 Weeks*
$207.45

Specifications

Sensor:
Field replaceable electrochemical, 4 year typical lifespan.
Range:
0 to 200 ppm.
Coverage Area:
5000 to 7000 sq. ft. typical.
Accuracy:
±2% FS at the time of calibration.
Output Drift:
<5% per year in air.
Temperature Limits:
-4 to 122°F (-20 to 50°C).
Storage Temperature:
For best sensor life, 32 to 68°F (0 to 20°C).
Humidity Limits:
15 to 90% RH constant; 0 to 99% RH intermittent.
Response Time:
<45 s. to 90% of final value.
Calibration:
15 turn span and zero adjustment potentiometers.
Housing:
UV resistant polycarbonate.
Output:
Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 kΩ).
Power Requirements:
Current Output: 18 to 28 VDC;
Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected.
Electrical Connection:
Removable terminal block, includes two PG11 and one PG 16 knockouts for conduit fitting.
Weight:
0.28 lb (0.11 kg).
Compliance:
CE.

Features

  • Field selectable current or voltage outputs
  • Replaceable sensor
  • Field calibration kits

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-505 Replacement carbon monoxide sensor for the Series GSTA, GSTC, & CMT200 1-2 Weeks*
$81.50
A-GSTA-SE Security enclosure. 1-3 days*
$18.65
A-507A Calibration adaptor. 1-2 Weeks*
$42.30
GCK-200CO-2000CO2 Gas Calibration Kit (GROUND SHIPMENTS ONLY) 1-3 days*
$726.55