Series UFM2 Compact Ultrasonic Flowmeters

Series UFM2 Compact Ultrasonic Flowmeters

Representative image displayed of UFB-122|Actual product may vary

UFB-122

Series UBT Clamp-On Ultrasonic Thermal Energy Meter

NEMA 4 Enclosure with Integral Mounting Bracket

The Series UBT Clamp-On Ultrasonic Thermal Energy Meter is an economical clamp-on ultrasonic heat meter. It is an ultrasonic alternative to the traditional inline thermal energy meters. The series uses temperature sensors for energy measurement and ultrasonic waves with time differentials for flow measurement.

Product Applications

  • Building services
  • Energy management
  • Heat/energy metering for energy management or building services utilizing chilled water circuits
Starting at $3,241.60
Grouped product items
Model Description Availability* Qty Price
UBT-14 3/4-4" Ultrasonic heat meter with pulse output. 6-7 Weeks*
$3,241.60
UBT-24 3/4-4" Ultrasonic heat meter with pulse output and Modbus® communications. 6-7 Weeks*
$3,413.45

Specifications

Service:
Clean water with <3% by volume of particulate content, or up to 30% ethylene glycol.
Range:
0.3 ft/s to 32 ft/s (0.1 m/s to 10 m/s).
Display:
Backlit: 2.28" x 0.43" (58 mm x 11 mm), 2 line x 16 characters.
Accuracy:
±3% of flow reading for velocity rate >1 ft/s (0.3 m/s).
Power Requirements:
12 V to 24 V ±10% AC/DC at 7 watts per unit. Optional plug-in 12 V power supply.
Power Consumption:
7 W (DC) or 7 VA (AC) max.
Temperature Limits:
Process: 32 to 185°F (0 to 85°C); Ambient: 32 to 122°F (0 to 50°C).
Outputs:
Pulse: 1 opto-isolated MOSFET relay, 500 mA max, 166 pps max, 200 Hz max.
Humidity Limit:
90% RH at 122°F (50°C) max.
Communication:
Pulse, optional Modbus® communication.
Enclosure Rating:
IP54.
Enclosure Material:
Plastic polycarbonate.
Repeatability:
±0.15% of measured value.
Electrical Connections:
16.4' (5 m) cable.
Flow Direction:
Any.
Mounting Orientations:
Any.
Weight:
1.10 lb (0.5 kg).
Agency Approvals:
CE.
ADDITIONAL SPECIFICATIONS
Applicable Pipe Material:
Steel, SS, copper, or plastic.
Pipe Outside Diameter:
3/4 to 4" (25 to 115 mm); 5 to 7" (125 to 180 mm). Pipe size is dependent on pipe material and internal diameter.
Applicable Pipe Lining:
None.
Pipe Wall Thickness:
0.02 to 0.36" (0.5 to 10 mm).

Features

  • Save on installation costs with non-invasive pipe measurement
  • Simplified installation with all necessary components included, such as converter, sensor, cables and mounting accessories
  • Fit application requirements with compact and lightweight design, that can be easily installed, all in one clamp-on unit intended for homogeneous liquids that contain no air
  • Cut down evaluation time with easy-to-read text displaying both energy rate and totalized energy with pulse output and communication options with a convenient backlight for visual comfort

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price