Series PBLT2 & PBLTX Submersible Level Transmitter

Series PBLT2 & PBLTX Submersible Level Transmitter

Series ULT Ultrasonic Level Transmitter

Series ULT Ultrasonic Level Transmitter

Series SBLT2 & SBLTX Submersible Level Transmitter

Perfect for Ground Water and Wells, Lightning Protected or Intrinsically Safe

The Series SBLT2 & SBLTX Submersible Level Transmitters are manufactured for years of trouble free service. These series measure the height of liquid above the position in the tank referenced to atmospheric pressure. The transmitter consists of a piezo resistive sensing element, encased in a 316 SS housing.

If you don't see the exact model in the ordering section, please use one of our product configurators below:

(Not UL Approved)

(UL Approved)


Product Applications

  • Well monitoring
  • Ground water monitoring
  • Environmental remediation
  • Surface water monitoring
  • Down hole
  • Water Tanks
Starting at $471.55
Filter By
Grouped product items
Model Description Availability* Qty Price
SBLT2-10-40-ETFE Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 40 ft (12.2 m) ETFE cable. 1-3 days*
$770.90
SBLT2-20-60 Submersible level transmitter, range 20 psi (46.18 ft wc) [14.08 m wc], 60 ft (18.3 m) polyurethane cable. 1-3 days*
$619.90
SBLT2-3.5M-5M Submersible level transmitter, range 3.5m wc, 5m polyurethane cable length. 1-3 days*
$471.55
SBLT2-5-40 Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) polyurethane cable. 1-3 days*
$550.90
SBLT2-5-40-ETFE Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) ETFE cable. 1-3 days*
$770.90
SBLT2-5M-10M Submersible level transmitter, range 5m wc, 10m polyurethane cable length. 1-3 days*
$526.75

Specifications

Service:
Compatible liquids.
Wetted Materials:
Body: 316 SS, 316L SS; Bullet nose: PVC; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer.
Accuracy:
±0.25% FS.
Temperature Limit:
SBLT2: Polyurethane: 0 to 150°F (-18 to 66°C); ETFE: 0 to 200°F (-18 to 93°C); SBLTX -4 to 176°F (-20 to 80°C); Polyurethane: -4 to 149°F (-20 to 65°C).
Compensated Temperature Range:
SBLT2: 0 to 140°F (-18 to 60°C); SBLTX: 0 to 176°F (-18 to 80°C).
Thermal Effect:
±0.02% full scale/°F.
Pressure Limit:
2X FS.
Power Requirement:
SBLT2: 10 to 30 VDC (≤1000 ft (305 m) of cable); SBLTX: 10 to 28 VDC.
Output Signal:
4 to 20 mA DC, 2-wire.
Response Time:
50 ms.
Max. Loop Resistance:
900 Ω at 30 VDC.
Electrical Connections:
Wire pigtail.
Mounting Orientation:
Suspended in tank below level being measured.
Electrical Protection:
SBLT2: Lightning and surge protection; SBLTX: None.
Weight:
2.2 lb (1.0 kg).
Compliance:
SBLT2: CE; SBLTX: CE, cULus intrinsically safe for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III Div. 1; ATEX: II 1 G Ex ia IIC T4 Ga and II 1 D Ex ia IIIC T135C Da (according to control drawing 001833-43)*.
Up to 275' (83.8 m) for ETFE cable; Up to 470' (143.3 m) for polyurethane cable.

Features

  • Meets application requirements with slim design with bullet nose design which protects the diaphragm from damage
  • Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on SBLT2 models
  • Eliminates particulate or water droplets from entering the transducer using maintenance-free filter
  • Peace of mind with UL approved intrinsically safe on SBLTX models for use in hazardous locations when used with proper barrier
  • Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility
  • Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation
  • Minimal downtime with standard 72 hour lead time

Options

  • -Intrinsically Safe Approval - Change model number from SBLT2 to SBLTX.
  • -Custom Ranges or Cable Lengths.

Model Chart

SBLT2-XX-XX-OPT      SBLT2 SUBMERSIBLE LEVEL TRANSMITTER

     1ST SYMBOL (1ST X) SENSOR (DECIMALS ALLOWED)
        ?     RANGE
              3-400 PSI OR 2.2-280 METERS
              RANGES < 3.552 PSI OR 2.5 METERS (1%)

     2ND SYMBOL (2ND X) SENSOR UNITS
              SENSOR RANGE IN PSI IF BLANK
        M     SENSOR RANGE IN METERS

     3RD SYMBOL (3RD X) CABLE LENGTH
        ?     10-2000 FT OR 3-600 METERS

     4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
              CABLE LENGTH IN FEET IF BLANK
        M     CABLE LENGTH IN METERS

     OPTIONS (OPT) KITS
       -ETFE  ETFE CABLE  (STD IS POLYURETHANE)
       -P1    1/4 IN NPTM (STD IS 7/16-14)
       -P2    1/4 IN NPTF
       -P3    1/4 IN BSPT MALE ISO 228 R
       -P4    1/4 IN BSPT FEMALE ISO 228 RC
       -P11   3/4 IN SNAP ON CAP

SBLTX-XX-XX-OPT      SBLTX SUBMERSIBLE LEVEL TRANSMITTER

     1ST SYMBOL (1ST X) SENSOR RANGE (DECIMALS ALLOWED)
        ?     RANGE
              3-400 PSI OR 2.2-280 METERS
              RANGES < 3.552 PSI OR 2.5 METERS (1%)

     2ND SYMBOL (2ND X) SENSOR UNITS
              SENSOR RANGE IN PSI IF BLANK
             M     SENSOR RANGE IN METERS
                    
     3RD SYMBOL (3RD X) CABLE LENGTH
        ?     10-195 FT ETFE   OR 10-330 FT PU
              3-59 METERS ETFE OR 3-100 METERS PU

     4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
              CABLE LENGTH IN FEET IF BLANK
        M     CABLE LENGTH IN METERS
 
     OPTIONS (OPT) KITS
       -ATEX  ATEX INTRINSICALLY SAFE
       -ETFE  ETFE CABLE  (STD IS POLYURETHANE)
       -P1    1/4 IN NPTM (STD IS 7/16-14)
       -P2    1/4 IN NPTF
       -P3    1/4 IN BSPT MALE ISO 228 R
       -P4    1/4 IN BSPT FEMALE ISO 228 RC
       -2YR   2 YEAR WARRANTY

Questions

Question
Our client has an MBLT pressure transmitter that appears to be malfunctioning due to scale buildup. The transmitter is installed to measure leachate level in a one-year old municipal sanitary landfill. What can we use to remove scale from the transmitter without damaging the transmitter?
Answer
If the issue is due to build-up which consequently plugs the small sensing holes, you might take a look at our PBLT2 or FBLT series. They are both more rugged and designed for sludge and slurries, whereas the MBLT and SBLT2 are better suited for cleaner applications such as ground water and wells.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-297 Desiccant filter for vent tube filter for submersible level transmitters. Removes humidity for protection of the sensor. Changes color to show saturation. 1-3 days*
$30.20
A-625 316 SS cable hanger use with NPT option for attaching chain for easy pulling out of application. 1-3 days*
$36.10
MTL7706 Intrinsically safe zener barrier for hazardous locations 1-3 days*
$646.05