EXAMPLE |
215 |
2 |
WT |
7810-10 |
C1 |
60 |
|
L12 |
215-2-WT-7810-10-C1-60-L12 Level Control, flanged carbon steel chamber, weatherproof enclosure, (2) SPDT snap action switches, lower stage adjustable deadband, upper stage fixed deadband, operating pressure 450 psig @ 100°F, side/bottom 1" NPT process connections, minimum s.g. 0.60. |
CONNECTION |
215 |
|
|
|
|
|
|
|
One Horizontal and One Vertical 1" NPT |
217 |
|
|
|
|
|
|
|
One Vertical and One Horizontal Flanged Connection |
218 |
|
|
|
|
|
|
|
Two Vertical Flanged Connections |
DEADBAND |
|
1 |
|
|
|
|
|
|
Single Stage Operation, with Adjustable Deadband |
|
2 |
|
|
|
|
|
|
Two Stage Operation, Lower Stage has Adjustable Deadband, Upper Stage has Fixed Deadband |
|
3 |
|
|
|
|
|
|
Two Stage Operation, Lower Stage has Fixed Deadband, Upper Stage has Adjustable Deadband |
|
4 |
|
|
|
|
|
|
Two Stage Operation, Both Stages have Fixed Deadband with Adjustable Spread Between Stages |
ENCLOSURE |
|
|
G |
|
|
|
|
|
General Purpose, NEMA 1 |
|
|
WT |
|
|
|
|
|
Weatherproof, NEMA 3R, 4, 4X |
|
|
E |
|
|
|
|
|
Explosion-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G |
|
|
EV |
|
|
|
|
|
Explosion-proof/Vapor-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G |
CIRCUITS
(for electrical circuits
see charts A & B below) |
|
|
|
48XX |
|
|
|
|
Single Stage Mercury Switch, see chart A |
|
|
|
48XX-XX |
|
|
|
|
Two Stage, Mercury Switch, see chart A |
|
|
|
78XX |
|
|
|
|
Single Stage, Snap Switch, see chart B |
|
|
|
78XX-XX |
|
|
|
|
Two Stage, Snap Switch, see chart B |
|
|
|
78XXHM |
|
|
|
|
Hermetically Sealed Snap Switch, see chart B |
|
|
|
98XX |
|
|
|
|
Single Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B |
|
|
|
98XX-XX |
|
|
|
|
Two Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B |
CHAMBER MATERIAL |
|
|
|
|
C1 |
|
|
|
Carbon Steel Body |
|
|
|
|
C216 |
|
|
|
316SS Body |
|
|
|
|
HFC1 |
|
|
|
Heat Fins & Carbon Steel Body |
|
|
|
|
HFC216 |
|
|
|
Heat Fins & 316SS Body (215 only) |
MINIMUM
SPECIFIC
GRAVITY |
|
|
|
|
|
60 |
|
|
0.60 Specific Gravity (215 only) |
|
|
|
|
|
160 |
|
|
0.60 Specific Gravity & 150# Flange (217, 218 only) |
|
|
|
|
|
360 |
|
|
0.60 Specific Gravity & 300# Flange (217, 218 only) |
|
|
|
|
|
660 |
|
|
0.60 Specific Gravity & 600# Flange (217, 218 only) |
LEVEL
CHANGE |
|
|
|
|
|
|
L12 |
|
Adjustable Level Change |
|
|
|
|
|
|
L24 |
|
Adjustable Level Change |
|
|
|
|
|
|
L36 |
|
Adjustable Level Change |
|
|
|
|
|
|
L48 |
|
Adjustable Level Change |
OPTIONS |
|
|
|
|
|
|
|
H2 |
H2 Socket Weld Hub (215, steel housing only) |
|
|
|
|
|
|
|
STW |
Stainless Steel Tag Wired |
|
|
|
|
|
|
|
01 |
Breather Only (E-Housing only) |
|
|
|
|
|
|
|
02 |
Drain Only (E-Housing only) |
|
|
|
|
|
|
|
12 |
Breather & Drain (E-Housing only) |
|
|
|
|
|
|
|
23720 |
Fungus Proofing |