EXAMPLE |
221 |
WT |
7810 |
C1 |
60 |
|
221-WT-7810-C1-60 Liquid Level Control, weatherproof enclosure, SPDT snap switch, fixed deadband, automatic reset, operating pressure 600 psig (41 bar) at 100°F (38°C), 550 psig (38 bar) at 475°F (246°C), side/bottom process connections, 1" NPT, minimum specific gravity 0.60. |
CONNECTION |
221 |
|
|
|
|
|
One Vertical and One Horizontal 1" NPT |
223 |
|
|
|
|
|
One Vertical and One Horizontal Flanged Connection |
224 |
|
|
|
|
|
Two Vertical Flanged Connections |
224T |
|
|
|
|
|
|
ENCLOSURE |
|
G |
|
|
|
|
General Purpose, NEMA 1 |
|
WT |
|
|
|
|
Weatherproof, NEMA 3R, 4, 4X |
|
E |
|
|
|
|
Explosion-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G. CSA approved Groups C, D, E, F, G only. |
|
EV |
|
|
|
|
Explosion-proof/Vapor-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G. CSA approved Groups C, D, E, F, G only. |
CIRCUITS
(for electrical circuits
see charts A & B below) |
|
|
48XX |
|
|
|
Single Stage Mercury Switch, see chart A |
|
|
48XX-XX |
|
|
|
Two Stage, Mercury Switch, see chart A |
|
|
78XX |
|
|
|
Single Stage, Snap Switch, see chart B |
|
|
78XX-XX |
|
|
|
Two Stage, Snap Switch, see chart B |
|
|
78XXHM |
|
|
|
Hermetically Sealed Snap Switch, see chart B |
|
|
98XX |
|
|
|
Single Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B |
|
|
98XX-XX |
|
|
|
Two Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B |
|
|
10XX |
|
|
|
Single Stage, High Temp. Snap Switch, continuous rating 800°F (425°C), see chart B |
|
|
10XX-XX |
|
|
|
Two Stage, High Temp. Snap Switch, continuous rating 800°F (425°C), see chart B |
CHAMBER MATERIAL |
|
|
|
C1 |
|
|
Carbon Steel Body |
|
|
|
C216 |
|
|
316SS Body |
|
|
|
HFC1 |
|
|
Heat Fins & Carbon Steel Body |
SPECIFIC
GRAVITY |
|
|
|
|
60 |
|
0.60 Specific Gravity (221 only) |
|
|
|
|
75 |
|
0.75 Specific Gravity (221 only) |
|
|
|
|
160 |
|
0.60 Specific Gravity & 150# Flange (223, 224 only) |
|
|
|
|
175 |
|
0.75 Specific Gravity & 150# Flange (223, 224 only) |
|
|
|
|
360 |
|
0.60 Specific Gravity & 300# Flange (223, 224 only) |
|
|
|
|
375 |
|
0.75 Specific Gravity & 300# Flange (223, 224 only) |
|
|
|
|
660 |
|
0.60 Specific Gravity & 600# Flange (223, 224 only) |
|
|
|
|
675 |
|
0.75 Specific Gravity & 600# Flange (223, 224 only) |
OPTIONS |
|
|
|
|
|
H2 |
H2 Socket Weld Hub (221, steel housing only) |
|
|
|
|
|
STW |
SS Tag Wired |
|
|
|
|
|
01 |
Breather Only (E-Housing only) |
|
|
|
|
|
02 |
Drain Only (E-Housing only) |
|
|
|
|
|
12 |
Breather & Drain (E-Housing Only) |
|
|
|
|
|
23720 |
Fungus Proofing |