Series RSM Room Status Monitor

Series RSM Room Status Monitor

Series RSMC StabiliSENSE™ Critical Room Status Monitor

Series RSMC StabiliSENSE™ Critical Room Status Monitor

Series RSME Room Status Monitor

Touchscreen LCD, Monitors Multiple Parameters

The Series RSME Room Status Monitor is designed for low differential pressure applications that require stringent pressure monitoring and alarming. It can be configured to monitor positive or negative pressure in clean rooms, hospital isolation rooms, laboratories, and vivariums. The RSME is a complete system with a touchscreen graphical user interface which enables access to pressure, humidity, temperature, air change, security, door status, calibration, and alarm setup. The graphical display color changes allow a clear determination of when the parameters are operating within the acceptable range (green), caution range (yellow), or have gone outside the acceptable operating range (red). The RSME room status monitor comes standard with BACnet MS/TP and Modbus® RTU communications.

Each RSME includes a factory calibration certificate.

Product Applications

  • Hospital isolation rooms
  • Pharmaceutical facilities
  • Dental offices
  • School nurse offices
Starting at $1,113.85
Filter By
Grouped product items
Model Description Availability* Qty Price
RSME-B-003

Room status monitor, range 0-0.5" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-B-004

Room status monitor, range 0-1.0" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-B-005

Room status monitor, range 0-2.0" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-B-014

Room status monitor, range -0.5-0-0.5" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-B-015

Room status monitor, range -1-0-1" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-B-016

Room status monitor, range -2-0-2" w.c., ± 0.5% accuracy

1-2 Weeks*
$1,432.10
RSME-C-003

Room status monitor, range 0-0.5" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-C-004

Room status monitor, range 0-1.0" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-C-005

Room status monitor, range 0-2.0" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-C-014

Room status monitor, range -0.5-0-0.5" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-C-015

Room status monitor, range -1-0-1" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-C-016

Room status monitor, range -2.0-0-2.0" w.c., ± 1.0% accuracy

1-2 Weeks*
$1,113.85
RSME-B-003-SS

Room status monitor, range 0-0.5" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-B-004-SS

Room status monitor, range 0-1.0" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-B-005-SS

Room status monitor, range 0-2.0" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-B-014-SS

Room status monitor, range -0.5-0-0.5" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-B-015-SS

Room status monitor, range -1-0-1" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-B-016-SS

Room status monitor, range -2-0-2" w.c., ± 0.5% accuracy with SS bezel

1-2 Weeks*
$1,538.20
RSME-C-003-SS

Room status monitor, range 0-0.5" w.c., ± 1.0% accuracy with SS bezel

1-2 Weeks*
$1,219.95
RSME-C-004-SS

Room status monitor, range 0-1.0" w.c., ± 1.0% accuracy with SS bezel

1-2 Weeks*
$1,219.95
RSME-C-005-SS

Room status monitor, range 0-2.0" w.c., ± 1.0% accuracy with bezel

1-2 Weeks*
$1,219.95
RSME-C-014-SS

Room status monitor, range -0.5-0-0.5" w.c., ± 1.0% accuracy with SS bezel

1-2 Weeks*
$1,219.95
RSME-C-015-SS

Room status monitor, range -1-0-1" w.c., ± 1.0% accuracy with SS bezel

1-2 Weeks*
$1,219.95
RSME-C-016-SS

Room status monitor, range -2.0-0-2.0" w.c., ± 1.0% accuracy with SS bezel

1-2 Weeks*
$1,219.95

Specifications

Service:
Air.
Measurement Technology:
Piezoresistive pressure sensor.
Wetted Materials:
Front: PMMA window with IP65 rating; Back housing: ABS UL 94 V-0.
Pressure Limits:
1.5 psig.
Accuracy:
±0.5% RSS (includes non-linearity: ±0.49% BFSL, hysteresis: ±0.05% and non-repeatability: ±0.05%), or ±1% RSS (includes non-linearity: ±0.99% BFSL, hysteresis: ±0.05% and non-repeatability: ±0.05%), after 1 hour warm-up period.
Process Connection:
Barbed, fits 1/8" and 3/16" (3 mm and 5 mm) ID rubber or vinyl tubing.
Inputs:
Two (2) user-selectable 4-20 mA, 0-5 VDC, or 0-10 VDC; USB type C used for cloning programming; One (1) digital input for door status.
Outputs:
One (1) digital output (DO) rated 5 A @ 30 VDC; One (1) 4-20 mA or 0-10 V (user selectable) corresponding to internal pressure or retransmission of any input.
Ambient Temperature Limits:
32 to 122°F (0 to 50°C).
Power Requirements:
24 VAC/VDC.
Selectable Pressure Units:
Pa, kPa, cm w.c., mm w.c., and in w.c.
Temperature Units:
°F and °C.
Zero and Span Adjustments:
Adjustable via touchscreen.
Power Consumption:
2.64 W max.
Electrical Connection:
Removable terminal block.
Display:
4.3" (10.9 cm) color TFT LCD, dimmable; 480 x 272 resolution.
Communications:
Modbus® RTU, BACnet MS/TP.
Audible Alarm:
69.1 dB 10 cm from display.
Weight:
13.6 oz (385.6 g).
Compliance:
BTL, CE.

Features

  • User configurable graphical interface
  • Monitors up to 3 rooms with a single unit
  • Displays up to 4 parameters including pressure, relative humidity, temperature, air change, and/or door status
  • Shallow mounting depth of 1.1" (27.5 mm) allows for flush mount installation in areas with space constraints
  • Full color 4.3" touchscreen LCD incorporates color status indication: green for good, yellow for warning, and red for alarm
  • Easy-to-clean optional brushed stainless steel bezel
  • BACnet MS/TP and Modbus® RTU communication is standard
  • Includes RSME, junction box, and USB-C/USB-A flash-drive

Options

  • NIST traceable calibration certificate

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Approvals

Model Chart

     RSME FLEXISENSE ROOM STATUS MONITOR 

         RSME-X-X-OPT
     
          1ST SYMBOL (1ST X) ACCURACY
             B     0.5% RSS
             C     1.0% RSS
 
          2ND SYMBOL (2ND X) RANGE
             003   0.5 INWC
             004   1 INWC
             005   2 INWC
             014   -0.5 TO 0.5 INWC
             015   -1 TO 1 INWC
             016   -2 TO 2 INWC
      
          OPTIONS (OPT)
            -COO   CERTIFICATE OF ORIGIN
            -NIST  NIST TRACEABLE CALIBRATION CERTIFICATE                
            -SS    STAINLESS STEEL BEZEL
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-220 Clear flexible vinyl tubing, 3/16" ID x 5/16" OD, lengths to 500'; 45 psi maximum pressure @ 73°F. 1-3 days*
$0.50
A-285 Remote alarm annunciator with visible/audible alarm and acknowledge switch 1-3 days*
$331.05
A-417A Static pressure pickup. For use in clean rooms, 60 micron filter picks up static pressure. Stainless steel wall plate fits 2" x 4" electrical box. Sealed with foam gasket, screws included. Barbed brass fitting holds 1/8" to 3/16" ID tubing. 1-3 days*
$12.65
A-418A Static Pressure Pickup. Room mount with Delta Style plastic enclosure fits 2" x 4" electrical box. Fine mesh screen hides static pressure pickup port. Clean connection to 1/8" to 3/16" I.D. tubing and pressure sensor. Sealed with foam gasket, screws included. 1-3 days*
$12.65
A-465 Flush mount space pressure sensor 1-3 days*
$13.95
A-RSME-BOX Surfact mount box for the Series RSME 9-10 Weeks*