Series IS626 Intrinsically Safe Pressure Transmitter

Series IS626 Intrinsically Safe Pressure Transmitter

Series DPT Digital Pressure Transmitter with Switches

Series DPT Digital Pressure Transmitter with Switches

Series 3200G Explosion-proof Pressure Transmitter

HART® Communication, Push Button Configuration, Rangeability (100:1)

The Mercoid® Series 3200G Explosion-Proof Pressure Transmitter is a microprocessor-based high performance transmitter, which has flexible pressure calibration, push button configuration, and programmable using HART® Communication. The Series 3200G is capable of being configured with the zero and span buttons, a field calibrator is not required for configuration. The transmitter software compensates for thermal effects, improving performance. EEPROM stores configuration settings and stores sensor correction coefficients in the event of shutdowns or power loss. The Series 3200G is FM approved for use in hazardous (Classified) locations. The 100:1 rangeability allows the smart transmitter to be configured to fit any application.

Product Applications

  • Water and wastewater
  • Chemical and petrochemical
  • Pulp and paper
  • Oil and gas
  • Food and beverage
Starting at $1,304.10
Filter By
Grouped product items
Model Description Availability* Qty Price
3200G-1-FM-1-1-LCD Smart pressure transmitter, range -14.5 to 21 psi with LCD display, (factory set 0 to 21 psig). 1-3 days*
$1,430.35
3200G-2-FM-1-1-LCD Smart pressure transmitter, range -14.5 to 217 psi with LCD display, (factory set 0 to 217 psig). 1-3 days*
$1,430.35
3200G-3-FM-1-1-LCD Smart pressure transmitter, range 0 to 725 psi with LCD display. 1-3 days*
$1,430.35
3200G-4-FM-1-1-LCD Smart pressure transmitter, range 0 to 3600 psi with LCD display. 1-3 days*
$1,430.35
3200G-2-FM-1-1 Smart pressure transmitter, range -14.5 to 217 psi, (factory set 0 to 217 psig). 1-3 days*
$1,304.10
3200G-3-FM-1-1 Smart pressure transmitter, range 0 to 725 psi. 1-3 days*
$1,304.10
3200G-4-FM-1-1 Smart pressure transmitter, range 0 to 3600 psi. 5-6 Weeks*
$1,304.10

Specifications

Service:
Compatible gases, steam, liquids or vapors.
Wetted Materials:
316L SS.
Accuracy:
±0.075% FS (@ 20°C).
Rangeability:
100:1 turn down.
Stability:
±0.125% FSO/yr.
Temperature Limits:
Process: -40 to 248°F (-40 to 120°C); Ambient: Without LCD -40 to 185°F (-40 to 85°C), With LCD -22 to 176°F (-30 to 80°C).
Thermal Effect:
±0.125% span/32°C.
Power Requirements:
11.9 to 45 VDC.
Output Signal:
4 to 20 mA / HART® Communication.
Response Time:
0.12 seconds.
Damping Time:
0.25 to 60 seconds.
Loop Resistance:
Operation: 0 to 1500 Ω HART® Communication: 250 to 500 Ω.
Electrical Connection:
Two 1/2" female NPT conduit, screw terminal.
Process Connections:
1/2" female NPT.
Display:
Optional: 5 digit LCD.
Enclosure Rating:
NEMA 4X (IP66) and explosion-proof for Class I, Div I Groups A, B, C and D.
Weight:
5.5 lb (2.5 kg).
Agency Approvals:
CE, FM.

Features

  • Completely configurable using zero/span buttons (no calibrator required)
  • Rangeablity (100:1)
  • High accuracy (±0.075%)
  • Automatic ambient temperature compensation
  • Fail-mode process function

Product Literature

Manuals

Catalog Pages

Model Chart

EXAMPLE 3200G 1 FM 1 1 LED S2 A1 00 H 2 X Options Series 3200G-1-FM-1-1-LEDS2A100H2-X, Explosion-Proof Pressure Transmitter, range -14.5-21 psig, FM approval, 1/2" female npt, extended diaphragm seal direct mount, 2" 316L stainless steel mtg flange, Ansi Class 150 rating, Hastelloy C-276 diaphragm, DC Silicon, capillary length
SERIES 3200G                                     Explosion-Proof Pressure Transmitter
RANGE    1
2
3
4
5
                                 -14.5-21 psig (factory set 0 to 21 psig)
-14.5-217 psig (factory set 0 to 217 psig)
0-725 psig
0-3600 psig
0-8500 psig
APPROVAL RATING       FM
WP

 
                           FM Approval
General Purpose NEMA 4X/IP66
PROCESS CONNECTIONS          1
3
                           1/2" Female NPT
Diaphragm Seal
ELECTRICAL CONNECTIONS             1                         1/2" Female NPT
DIAPHRAGM SEAL TYPE                LED
LES
LFD
LFS
                     Extended Diaphragm Seal Direct Mount
Extended Diaphragm Seal Capillary Type
Flush Diaphragm Seal Direct Mount
Flush Diaphragm Seal Capillary Type
MOUNTING FLANGE                   S2
S3
                  2" (50mm) 316L Stainless Steel
3" (80mm) 316L Stainless Steel
MOUNTING FLANGE RATING                      A1
A2
D1
D2
J1
J2
               ANSI Class 150
ANSI Class 300
DIN pn 10/16
DIN pn 25/40
JIS 10k
JIS 20k
EXTENSION LENGTH                         00
05
10
15
            No Extension Standard Option for Flush Mount
2" (50mm)
4" (100mm)
6" (150mm)
WETTED PARTS                            H
P
S
T
         Hastelloy C-276 Diaphragm
PTFE and 316L Stainless Steel Diaphragm
316L Stainless Steel Diaphragm
Tantallum Diaphragm
FILL FLUID                               2       D.C. Silicon 200 (-40-400° F)
CAPILLARY LENGTH                                  X    Capillary length 0-20 feet (whole numbers only)
OPTIONS                                     LCD
SSH
CC
NIST
5 Digit LCD
316 Stainless Steel Housing
Custom Calibration
NIST Traceable Calibration Certificate

Questions

Question
What is specified by the temperature coefficient and how is it important to my readings?
Answer
As the ambient temperature changes, the output current will drift slightly. The temperature coefficient specifies the amount of drift per °F/°C. Since the temperature affects the transmitter output, the temperature coefficient is important to accuracy of your reading.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-630 316SS angle bracket with bolts. 1-3 days*
$133.10
A-631 316SS flat bracket with bolts 1-3 days*
$133.10
BBV-0N 2-valve block manifold 1-3 days*
$349.85