Series WE05 3-Piece Socket Weld Stainless Steel Ball Valve

Series WE05 3-Piece Socket Weld Stainless Steel Ball Valve

Series WE07 2-Piece Flanged Stainless Steel V-Ball Valve

Series WE07 2-Piece Flanged Stainless Steel V-Ball Valve

Series WE06 3-Piece NPT Stainless Steel V-Ball Valve

V-Port, Vented Ball, Electric or Pneumatic Actuators

The Series WE06 incorporates a V-port ball valve for impressive flow rates with minimal pressure drop. Quarter turn control ball valves are compact, lighter weight and much less expensive than comparable sized globe valves and segmented control valves. They also offer bubble tight shut off with zero leakage and can withstand high pressure drops. The 60° and 90° balls offer an equal percentage flow characteristic. W. E. Anderson’s V-port ball valves have been designed to offer maximum flow characteristics that are substantially higher than comparably sized globe valves. The natural flow pattern of ball valves increases flow rates and in many applications valves smaller than pipeline size can be used. Actuators are directly mounted creating a compact assembly for tight spaces. Limit switches can be mounted directly to the valves allowing for remote position indication. The Series WE06 can be configured with an electric or pneumatic actuator. Electric actuators are available in weatherproof or explosion-proof, a variety of supply voltages and two-position modulating control. Two-position actuators use the supply voltage to drive the valve open or close, while the modulating actuator accepts a 4 to 20 mA input for valve positioning. Actuators feature thermal overload protection and a permanently lubricated gear train. The pneumatic double acting actuator uses an air supply to drive the valve open and closed. The actuator has two supply ports with one driving the valve open and the other driving the valve closed. Spring return pneumatic actuators use the air supply to open the valve and internally loaded springs return the valve to the closed position. Also available is the SV3 solenoid valve to electrically switch the air supply pressure between the air supply ports for opening and closing the valve. Actuators are constructed of anodized and epoxy coated aluminum for years of corrosion free service.

Product Applications

  • Gas or liquid flow control
  • Ideal for bubble tight shut off at high pressure drops
Grouped product items
Model Description Availability* Qty Price

Specifications

VALVE
Service:
Compatible liquids and gases.
Body:
3-piece.
Line Sizes:
1/2 to 3".
End Connections:
Female NPT.
Pressure Limits:
20" Hg to 1000 psi (-0.7 to 69 bar), up to 250°F.
Wetted Materials:
Body and ball: 316 SS (CF8M); Stem: 316 SS; Seat: RTFE/PTFE; Seal, Washer, and Packing: PTFE.
Temperature Limits:
-20 to 392°F (-29 to 200°C).
Other Materials:
O-ring: Fluoroelastomer; Handle: 304 SS; Washer: 301 SS; Stem Nut, Locking Device, Gland Ring: 304 SS; Handle Sleeve: PVC.
Agency Approvals:
Meets the technical requirements of EU Directive 2011/65/ EU (RoHS II).

ACTUATORS
Pneumatic “DA” and “SR” Series
Type:
DA series is double acting and SR series is spring return (rack and pinion).
Normal Supply Pressure:
DA: 40 to 115 psi (2.7 to 7.9 bar); SR: 80 psi (5.5 bar).
Maximum Supply Pressure:
120 psi (8.6 bar).
Air Connections:
DA01: 1/8" female NPT; DA02 to DA05: 1/4" female NPT; SR02 to SR07: 1/4" female NPT.
Housing Material:
Anodized aluminum body and epoxy coated aluminum end caps.
Temperature Limits:
-40 to 176°F (-40 to 80°C).
Accessory Mounting:
NAMUR standard.

Electric “TD” and “MD” Series
Power Requirements:
110 VAC, 220 VAC, 24 VAC or 24 VDC (MD models not available in 24 VDC).
Power Consumption:
See instruction manual.
Cycle Time (per 90°):
TD01: 4 s; MD01: 10 s; TD02 and MD02: 20 s; TD03 and MD03: 30 s.
Duty Rating:
85%.
Enclosure Rating:
NEMA 4X (IP67).
Housing Material:
Powder coated aluminum.
Temperature Limits:
-22 to 140°F (-30 to 60°C).
Electrical Connection:
1/2" female NPT.
Modulating Input:
4 to 20 mA.
Standard Features:
Manual override, position indicator, and TD models come with two limit switches.

Electric “TI” and “MI” Series
Power Requirements:
110 VAC, 220 VAC, 24 VAC or 24 VDC.
Power Consumption:
See instruction manual.
Cycle Time (per 90°):
See instruction manual.
Duty Rating:
See instruction manual.
Enclosure Rating:
NEMA 7, designed to meet hazardous locations: Class I, Group C & D; Class II, Group E, F & G; Division I & II.
Housing Material:
Powder coated aluminum.
Temperature Limits:
-40 to 140°F (-40 to 60°C).
Electrical Connection:
1/2" female NPT.
Modulating Input:
4 to 20 mA.
Standard Features:
Position indicator and two limit switches.

Features

  • The 60° and 90° balls offer an equal percentage flow characteristic
  • Limit switches can be mounted to manual valves for remote monitoring
  • Available with a variety of electric and pneumatic actuators

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Model Chart

WE06-X-X-XXX   WE06 PNEUMATIC 3-PIECE SCREWED END SST V-BALL VALVE

        1ST SYMBOL (1ST X) RANGE
           CHD00   1/2 IN HAND OPERATED
           DHD00   3/4 IN HAND OPERATED
           EHD00   1 IN HAND OPERATED
           FHD00   1-1/4 IN HAND OPERATED
           GHD00   1-1/2 IN HAND OPERATED
           HHD00   2 IN HAND OPERATED
           IHD00   2-1/2 IN HAND OPERATED
           JHD00   3 IN HAND OPERATED
           CDA01   1/2 IN DOUBLE ACTING
           DDA01   3/4 IN DOUBLE ACTING
           EDA02   1 IN DOUBLE ACTING
           FDA02   1-1/4 IN DOUBLE ACTING
           GDA03   1-1/2 IN DOUBLE ACTING
           HDA03   2 INDOUBLE ACTING
           IDA04   2-1/2 IN DOUBLE ACTING
           JDA05   3 IN DOUBLE ACTING
           CSR02   1/2 IN SPRING RETURN
           DSR02   3/4 IN SPRING RETURN
           ESR03   1 IN SPRING RETURN
           FSR03   1-1/4 INSPRING RETURN
           GSR04   1-1/2 IN SPRING RETURN
           HSR05   2 IN SPRING RETURN
           ISR07   2-1/2 IN SPRING RETURN
           JSR07   3 IN SPRING RETURN

        2ND SYMBOL (2ND X) V-BALL ANGLE
           T       60 DEGREE V-BALL
           N       90 DEGREE V-BALL

        3RD SYMBOL (3RD X) SOLENOID 
           N       NO SOLENOID
           A       NEMA 4X NAMUR SOLENOID

        4TH SYMBOL (4TH X) SOLENOID
           N       NO SOLENOID
           A       110 VAC
           B       220 VAC
           C       24 VAC
           D       24 VDC
           E       12 VDC

        5TH SYMBOL (5TH X) POSITIONERS AND SWITCHES                   
           00      NONE
           01      42ADO EXP LIMIT SWITCH
           02      45VDO EXP POSITION TRANSMITTER
           03      42ADO-B ATEX LIMIT SWITCH
           04      42ADO-IE IECEX LIMIT SWITCH          
           06      QV-210101 POLY LIMIT SWITCH
           07      VPS AND P1 PROX SWITCH
           08      265ER-D5 POSITIONER
           09      285ER-D5 SMART POSITIONER

    OPTIONS (OPT) (PNEUMATIC ACTUATORS ONLY)                   
           -NO     FAIL OPEN SPRING RETURN ACTUATOR 
WE06-X-X-XXX   WE06 ELECTRIC 3-PIECE SCREWED END SST V-BALL VALVE

        1ST SYMBOL (1ST X) RANGE          
           CTD01   1/2 IN ELECTRIC TWO-POSITION
           DTD01   3/4 IN ELECTRIC TWO-POSITION
           ETD01   1 IN ELECTRIC TWO-POSITION
           FTD01   1-1/4 IN ELECTRIC TWO-POSITION
           GTD02   1-1/2 IN ELECTRIC TWO-POSITION
           HTD02   2 IN ELECTRIC TWO-POSITION
           ITD03   2-1/2 IN ELECTRIC TWO-POSITION
           JTD03   3 IN ELECTRIC TWO-POSITION
           CMD01   1/2 IN ELECTRIC MODULATING
           DMD01   3/4 IN ELECTRIC MODULATING
           EMD01   1 IN ELECTRIC MODULATING
           FMD01   1-1/4 IN ELECTRIC MODULATING
           GMD01   1-1/2 IN ELECTRIC MODULATING
           HMD02   2 IN ELECTRIC MODULATING
           IMD03   2-1/2 IN ELECTRIC MODULATING
           JMD03   3 IN ELECTRIC MODULATING
           CTI01   1/2 IN EXP ELECTRIC TWO-POSITION
           DTI01   3/4 IN EXP ELECTRIC TWO-POSITION
           ETI02   1 IN EXP ELECTRIC TWO-POSITION
           FTI02   1-1/4 IN EXP ELECTRIC TWO-POSITION
           GTI03   1-1/2 IN EXP ELECTRIC TWO-POSITION
           HTI04   2 IN EXP ELECTRIC TWO-POSITION
           ITI05   2-1/2 IN EXP ELECTRIC TWO-POSITION
           JTI05   3 IN EXP ELECTRIC TWO-POSITION
           CMI01   1/2 IN EXP ELECTRIC MODULATING
           DMI01   3/4 IN EXP ELECTRIC MODULATING
           EMI02   1 IN EXP ELECTRIC MODULATING
           FMI02   1-1/4 IN EXP ELECTRIC MODULATING
           GMI03   1-1/2 IN EXP ELECTRIC MODULATING
           HMI04   2 IN EXP ELECTRIC MODULATING
           IMI05   2-1/2 IN EXP ELECTRIC MODULATING
           JMI05   3 IN EXP ELECTRIC MODULATING

       2ND SYMBOL (2ND X) V-BALL ANGLE
           T       60 DEGREE V-BALL
           N       90 DEGREE V-BALL

      3RD SYMBOL (3RD X) ACTUATOR VOLTAGE (ELECTRIC ACTUATORS)
           N       NO SOLENOID
           A       110 VAC
           B       220 VAC
           C       24 VAC
           D       24 VDC
           E       12 VDC
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
VB-01 Volume booster, 1.02 Cv, 1/4" NPT in/out connection, aluminum 12-13 Weeks*
$500.95