Series TUF Ultrasonic Energy Meter

Series TUF Ultrasonic Energy Meter

Series UBT Clamp-On Ultrasonic Thermal Energy Meter

Series UBT Clamp-On Ultrasonic Thermal Energy Meter

Series UFM2 Compact Ultrasonic Flowmeters

Cost Effective, Compact and Adjustable Design, Non-Invasive

The Series UFM2 Compact Ultrasonic Flowmeters are economical, clamp-on, ultrasonic flowmeters. The UFM2 implements the transit-time difference to measure flow rates in pipes and can measure velocity and flow in pipes with outside diameters ranging from 3/4 to 7" (25 to 180 mm). This model comes with a volume pulse and 4-20 mA flow rate output.

KIT INCLUDES:
• Converter with adjustable guide rail
• Set of pipe clamps (model dependent)
• Set of small pipe adapter circle clamps
• Set of small pipe adapter V clamps
• Ultrasonic coupling grease

Product Applications

  • Flow measurement for heat metering
  • Metering and monitoring in: Chilled water, Potable water, Process water
Starting at $2,982.50
Grouped product items
Model Description Availability* Qty Price
UFM2-14 Compact ultrasonic flowmeter, pulse and 4-20 mA outputs, 3/4 to 4" (25 to 115 mm) pipe 1-3 days*
$2,982.50
UFM2-16 Compact ultrasonic flowmeter, pulse and 4-20 mA outputs, 5 to 7" (125 to 180 mm) pipe 5-6 Weeks*
$3,578.95

Specifications

Service:
Clean water with <3% by volume of particulate content.
Range:
0.33 to 32.8 ft/s (0.1 to 10 m/s).
Display:
Backlit: 3.27" H x 0.74" W (83.1 mm x 18.8 mm), 2 line x 16 characters.
Accuracy:
±3% of flow reading for >0.98 ft/s (>0.3 m/s).
Power Requirements:
12-24 VDC/VAC.
Power Consumption:
7 W max.
Temperature Limits:
Process: 32 to 185°F (0 to 85°C); Ambient: 32 to 122°F (0 to 50°C).
Outputs:
Analog: 1 opto-isolated: 4-20 mA; Error current: 3.5 mA; Load resistance: 620 Ω max; Pulse: 1 optoisolated MOSFET relay, 500 mA max, 166 pps max, 200 Hz max.
Enclosure Rating:
IP54.
Enclosure Material:
Plastic polycarbonate.
Repeatability:
±0.15% of measured value.
Electrical Connections:
16.4' (5 m) cable.
Response Time:
<1 s.
Weight:
2.9 lb (1.315 kg).
Agency Approvals:
CE.

ADDITIONAL SPECIFICATIONS
Applicable Pipe Material:
Steel, copper, or plastic.
Pipe Outside Diameter:
3/4 to 7" (25 to 180 mm). Pipe size is dependent on pipe material and internal diameter.
Applicable Pipe Lining:
None.
Pipe Wall Thickness:
0.02 to 0.39" (0.5 to 10 mm).

Features

  • Save on installation costs with non-invasive pipe measurement
  • Simplified installation with all necessary components included, such as converter, sensor, cables and mounting accessories
  • Fit application requirements with compact and lightweight design, that can be easily installed, all in one clamp-on unit intended for homogeneous liquids that contain no air
  • Cut down evaluation time with easy-to-read text displaying both flow rate and total with a convenient backlight for visual comfort

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
NISTCAL-FU NIST traceable calibration certificate for ultrasonic flowmeters. NOTE: EQUAL CERTS WILL BE CHARGED PER UNITS PURCHASED. 2-3 Weeks*
$405.00
A-186 Silicone based grease acoustic couplant, 3 oz. tube. 1-3 days*
$21.20