The Series 16G, 8G, AND 4G Temperature/Process Loop Controllers allow for monitoring and control of temperature or process conditions. The controller features two independent control outputs for dual loop control using on/off, auto-tune or self-tune PID, fuzzy logic, or manual control methods. RS-485 interface is included with Modbus® communication protocol, for easy bench-top configuration or integration with a PLC or data control system.

Product Applications

  • Oven control
  • Packaging equipment
  • Parts washers
Starting at $61.06
Filter By
Grouped product items
Model Description Availability* Qty Price
16G-23-11 1/16 DIN temperature/controller, volt pulse/relay RS485, 2 event inputs 1-3 days*
$177.50
16G-23-31 1/16 DIN temperature/controller, volt pulse/relay RS485, 1 event input, temp retransmission 1-3 days*
$186.00
16G-23-32 1/16 DIN temperature/controller, volt pulse/relay RS485, temp retransmission, remote setpoint Call for Details*
$61.06
16G-33-11 1/16 DIN temperature/controller, relay/relay RS485, 2 event inputs Call for Details*
$177.50
16G-33-31 1/16 DIN temperature/controller, relay/relay RS485, 1 event input, temp retransmission 1-3 days*
$186.00
16G-33-32 1/16 DIN temperature/controller, relay/relay RS485, temp retransmission, remote setpoint 1-3 days*
$187.80
16G-53-32 1/16 DIN temperature/controller, current/relay, RS485, temp retransmission, remote setpoint 1-3 days*
$187.80
16G-63-11 1/16 DIN temperature/controller, linear voltage/relay, RS485, 2 event inputs 1-3 days*
$177.50
16G-63-31 1/16 DIN temperature/controller, linear voltage/relay, RS485, 1 event input, temp retransmission Call for Details*
$183.20
4G-33-11 1/4 DIN temperature/controller, relay/relay, RS485, 2 event input Call for Details*
$207.45
4G-53-11 1/4 DIN temperature/controller, current/relay, RS485, 2 event input Call for Details*
$211.25
4G-53-31 1/4 DIN temperature/controller, current/relay, RS485, 1 event input, temp retransmission 1-3 days*
$214.65
4G-53-32 1/4 DIN temperature/controller, current/relay, RS485, temp retransmission, remote setpoint Call for Details*
$219.80
4G-63-31 1/4 DIN temperature/controller, linear voltage/relay, RS485, 1 event input, temp retransmission Call for Details*
$214.65
4G-63-32 1/4 DIN temperature/controller, linear voltage/relay, temp retransmission, remote setpoint Call for Details*
$220.45
8G-23-31 1/8 DIN temperature/controller, volt pulse/relay, RS485, 1 event input, temp retransmission 1-3 days*
$210.20
8G-33-31 1/8 DIN temperature/controller, relay/relay, RS485, 1 event input, temp retransmission Call for Details*
$210.20

Specifications

Inputs:
Thermocouple, RTD, DC voltages or DC current.
Display:
Process value: 4 digit, 0.47" H (12mm), orange LCD; Set point value: 4 digit, 0.47" H (12mm), green LCD.
Accuracy:
± 1.8°F plus ±0.3% of span (±1°C plus ±0.3% of span) at 77°F (25°C) after 20 minutes warm up.
Power Requirements:
100 to 240 VAC -20/+8%, 50/60 Hz; Optional 24 VDC, ±10%.
Power Consumption:
5 VA max.
Operating Temperature:
32 to 122°F (0 to 50°C).
Storage Temperature:
-42 to 150°F (-20 to 65°C).
Memory Backup:
Nonvolatile memory.
Control Output Ratings:
Relay: SPST, 5 A @ 250 VAC resistive; Voltage pulse: 12 V (max. 40 mA); Current: 4 to 20 mA; Linear voltage: 0 to 10 V.
Alarm Relay Ratings:
3 A @ 250 VAC resistive.
Communication:
RS-485 Modbus® ASCII/RTU communication protocol.
Weight:
9 oz (255g).
Front Panel Rating:
IP66.
Agency Approvals:
CE, cULus.

Features

  • On/off, PID, fuzzy logic, or manual output control
  • Constant, sloped, program (ramp/soak), or remote set-point control
  • 2 primary control outputs, 2 secondary/alarm relay outputs, and RS-485 standard on all models
  • Remote set-point, input retransmission, or event input functions available with optional hardware

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Questions

Question
I have a Love 16B-33-LV temp controller that came with a DC01 jumper. Can you tell me what this jumper is for?
Answer
The jumper is used when you are using a current input (4-20 mA) signal into the controller. If you are using an RTD or thermocouple probe you do not need this jumper.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-901 Weatherproof enclosure, type 4X, clear plastic window with rear panel for mounting the control inside the enclosure. 1-3 days*
$356.05
A-TC-J50-FB J type, 50' on spool, fiber glass insulation, 450°C, black outer sheath, 24 AWG, 0.20 SQMM 1-2 Weeks*
$35.75
A-TC-J50-FEP J type, 50’ on spool, FEP insulation, 200°C, black outer sheath, 24 AWG, 0.20 SQMM 1-2 Weeks*
$28.10
MN-1 Mini-Node™ RS-485 to USB converter 1-3 days*
$108.35
A-600 R/C snubber (recommended for inductive loads like a solenoid or contactor) 1-3 days*
$25.75
A-900 Weatherproof enclosure, type 4X, control direct panel mounts in the front of the enclosure. 1-3 days*
$191.95