Series 647 Wet/Wet Differential Pressure Transmitter

Series 647 Wet/Wet Differential Pressure Transmitter

Base mount

Series 610 Low Differential Pressure Transmitter

Series DM-2000 Differential Pressure Transmitter

Quick Response, Easy Calibration Checks

The Dwyer Series DM-2000 Differential Pressure Transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The DM-2000 housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic® gage. A wide range of models are available factory calibrated to specific ranges.

Pressure connections are inherent to the glass filled plastic molded housing making installation quick and easy. Digital push-button zero and span simplify calibration over typical turn-potentiometers. An optional 3.5 digit LCD shows process and engineering units. A single push button allows field selection of 4 to 6 engineering units depending on range.

LIMITED QUANTITIES AVAILABLE.

Product Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
Starting at $180.95
Grouped product items
Model Description Availability* Qty Price
DM-2004-LCD Differential pressure transmitter, range 1.00" w.c., 249 Pa, 25.4 mm w.c., 2.49 mbar, .249 kPa, black overlay with LCD display Less Than 1 Week*
$180.95
DM-2105-LCD Differential pressure transmitter, range 2.00" w.c., 497 Pa, 50.8 mm w.c., 4.97 mbar, .497 kPa., light gray overlay with LCD display Less Than 1 Week*
$180.95

Specifications

Service:
Air and non-combustible, compatible gases.
Wetted Materials:
Consult Factory.
Accuracy:
±1% FS, ±30 Pa model ±4% FS at 70°F.
Stability:
±1% FS/yr.
Temperature Limits:
20 to 120°F (-6.67 to 48.9°C).
Pressure Limits:
10 psig (0.69 bar).
Thermal Effect:
±0.055% FS/°F (0.099% FS/°C), ±30 Pa model ±0.13% FS/°F (0.234% FS/°C).
Power Requirements:
10 to 35 VDC (2 wire).
Output Signal:
4 to 20 mA.
Zero and Span Adjustments:
Digital push-button zero and span.
Loop Resistance:
DC: 0 to 1250 Ω maximum.
Current Consumption:
DC: 38 mA max.
Electrical Connections:
Screw-type terminal block.
Display:
3.5 digit LCD, 0.7" height.
Process Connections:
1/8" I.D. tubing.
Mounting Orientation:
Vertical.
Weight:
4.8 oz (136 g).

Features

  • Zero and span controls provide easy calibration checks and shorter installation time to get device running and monitoring
  • Quick response to pressure changes means no delay in signaling and alerting to critical situations
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Same size as Magnehelic simplifies field upgrade to digital pressure gage by reducing install steps
  • Tamper proof button configuration to prevent accidental changes to the settings

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Model Chart

EXAMPLE DM 20 01 AT Series DM-2001-AT Differential Pressure Transmitter, black background, range 0-0.1" w.c., with aluminum tag.
SERIES DM       Differential Pressure Transmitter
GAGE BACKROUND
COLOR
  20
21
    Black
Light Gray
RANGE     01
02
03
04
05
06
07
12
13
19
40
  0 to 0.1" w.c.
0 to 0.25" w.c.
0 to 0.5" w.c.
0 to 1" w.c.
0 to 2" w.c.
0 to 3" w.c.
0 to 5" w.c.
0 to ±0.25" w.c.
0 to ±0.5" w.c.
0.05-0-0.20" w.c.
30-0-30 Pa
OPTIONS       AT
LCD
NIST
Aluminum Tag
LCD Display
NIST Certificate of Calibration