EXAMPLE |
F7-MM |
B |
1 |
5 |
F1 |
1 |
01.25 |
03.50 |
09.75 |
12.00 |
15.95 |
20.00 |
12 |
Series F7-MMB1-5F11-01.25-03.50-09.75-12.00-15.95-20.00-12 Miniature Multi-Station Level Switch, brass with beryllium copper stops, 1/8" NPT, 5 switch points, Buna-N float, min. s.g. 0.45, max. pressure 300 psi, SPST, .17A @ 120VAC, L5 set point distance 1.25", L4 set point distance 3.5", L3 set point distance 9.75", L2 set point distance 12", L1 set point distance 15.95", 20" overall length, with 12' lead wire. |
SERIES |
F7-MM |
|
|
|
|
|
|
|
|
|
|
|
|
Miniature Multi-Station Level Switch |
STEM & CONN.
MATERIAL |
|
B
S |
|
|
|
|
|
|
|
|
|
|
|
Brass with Beryllium Copper Stops
316SS with SS Armco PH-15-7MO Stops |
CONNECTION
TYPE |
|
|
1
2
3
4
5
6
7 |
|
|
|
|
|
|
|
|
|
|
1/8" NPT
3/4" NPT (cannot be used with float F1, F3, F7 and F8)
1" NPT (cannot be used with float F3)
3-5/8" Flange [maximum pressure is 50 psi (3.45 bar)]
1-5/16-12UNF-2A (cannot be used with float F3)
3/8-24
2" NPT and 1/2 conduit (only use with float F3 and 316SST) |
NUMBER OF
SWITCH
POINTS |
|
|
|
1
2
3
4
5 |
|
|
|
|
|
|
|
|
|
1 Switch Point
2 Switch Points
3 Switch Points
4 Switch Points
5 Switch Points |
FLOAT TYPE |
|
|
|
|
F1
F2
F3
F4
F5
F6
F7
F8 |
|
|
|
|
|
|
|
|
Buna-N, Min. S.G. 0.45, Max. Pressure 300 psi (20.68 bar)
Buna-N, Min. S.G. 0.60, Max. Pressure 250 psi (17.24 bar)
316SS, Min. S.G. 0.70, Max. Pressure 100 psi (6.89 bar)
316SS, Min. S.G. 0.85, Max. Pressure 150 psi (10.34 bar)
316SS, Min. S.G. 1.10, Max. Pressure 400 psi (27.58 bar)
TFE, Min. S.G. 0.65, Max. Pressure 1000 psi (68.95 bar)
316SS, Min. S.G. 0.85, Max. Pressure 275 psi (18.96 bar)
316SS, Min. S.G. 0.90, Max. Pressure 600 psi (41.37 bar) |
SWITCH TYPE |
|
|
|
|
|
1
2 |
|
|
|
|
|
|
|
SPST, .17 A @ 120 VAC
SPST, .8 A @ 120 VAC
NO switch is standard. For NC place and "*" after the corresponding set point distance in the model number. |
SET POINT
DISTANCE
(L5) |
|
|
|
|
|
|
00.00 |
|
|
|
|
|
|
In inches referenced from bottom of connection. Example: 01.25 would be 1.25" from the bottom of the process connection. |
SET POINT
DISTANCE
(L4)
|
|
|
|
|
|
|
|
00.00 |
|
|
|
|
|
In inches referenced from bottom of connection. Example: 03.50 would be 3.5" from the bottom of the process connection. |
SET POINT
DISTANCE
(L3) |
|
|
|
|
|
|
|
|
00.00 |
|
|
|
|
In inches referenced from bottom of connection. Example: 09.75 would be 9.75" from the bottom of the process connection. |
SET POINT
DISTANCE
(L2) |
|
|
|
|
|
|
|
|
|
00.00 |
|
|
|
In inches referenced from bottom of connection. Example: 12.00 would be 12" from the bottom of the process connection. |
SET POINT
DISTANCE
(L1) |
|
|
|
|
|
|
|
|
|
|
00.00 |
|
|
In inches referenced from bottom of connection. Example: 15.95 would be 15.95" from the bottom of the process connection. |
OVERALL
LENGTH
(LO) |
|
|
|
|
|
|
|
|
|
|
|
00.00 |
|
Maximum overall length of 48" (121 cm). Minimum length is L1 + D. |
OPTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
CG
J
00 |
Common Ground Leads
Junction Box for Wire Leads, NEMA 4
Lead Wire Length (in feet) |