Series RHRS Outside Air Humidity Radiation Shield

Series RHRS Outside Air Humidity Radiation Shield

Series RHPLC Wall Mount Humidity/Temperature Transmitter

Series RHPLC Wall Mount Humidity/Temperature Transmitter

Series RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter

Optional LCD Display

The Series RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter is the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. The humidity and the dew point are measured using a capacitive polymer sensor that completely recovers from 100% saturation. The humidity and dew point can have either a current or voltage output, while the optional temperature output can be a current, voltage, RTD or thermistor. For models with current or voltage for the temperature output, the temperature range is field selectable.

For models with resistive thermistors or RTD outputs, click here for Resistance vs. Temperature Table.

Product Applications

  • Air economizers
  • Room comfort monitoring
  • Greenhouse monitoring
Filter By
Grouped product items
Model Description Availability* Qty Price
RHP-2E44 European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature 1-3 days*
$137.55
RHP-2N44 North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature 1-3 days*
$148.50
RHP-2N44-LCD North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature with LCD 1-3 days*
$214.55
RHP-2N4B North American Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor 1-3 days*
$142.95
RHP-3E40-LCD European Wall Mount Humidity Transmitter with 3% accuracy and universal current / voltage output for RH with LCD Less Than 1 Week*
$179.90
RHP-3N44 North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature 1-3 days*
$136.25
RHP-3N44-LCD North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and Temperature with LCD 1-3 days*
$202.30
RHP-3N4A North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type III thermistor Temperature Sensor 1-2 Weeks*
$130.70
RHP-3N4B North American Wall Mount Humidity / Temperature Transmitter with 3% accuracy and universal current / voltage output for RH and 10K Type II thermistor Temperature Sensor 1-3 days*
$130.70

Specifications

Relative Humidity Range:
0 to 100% RH.
Temperature Range:
-40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors.
Dew Point Temperature Range:
-20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges.
Accuracy:
RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to 80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C).
Hysteresis:
±.8%.
Repeatability:
±0.1% typical.
Temperature Limits:
Operating: -40 to 140°F (-40 to 60°C); Storage: -40 to 176°F (-40 to 80°C).
Compensated Temperature Range:
-4 to 140°F (-20 to 60°C).
Power Requirements:
4-20 mA loop powered outputs: 10-35 VDC; 0-5/10V outputs: 15-35 VDC or 15-29 VAC.
Output Signals:
4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/ solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output.
Solid State Band Gap Temp Sensor Output Ranges:
Switch selectable, -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C).
Response Time:
8 s.
Electrical Connections:
Screw terminal block.
Drift:
<.25% RH/year.
RH Sensor:
Capacitance polymer.
Enclosure Material:
Polycarbonate.
Enclosure Rating:
IP20.
Display:
Optional LCD; Switch selectable %RH or dew point, °F/°C.
Display Resolution:
RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C).
Weight:
4.4 oz (125 g).
Compliance:
CE.

Features

  • Reduced installation cost with combined humidity/dew point and temperature sensing
  • Wide application environments from a large selection of temperature sensors and 2% and 3% accuracies
  • Reduced inventory with field selectable output

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Approvals

Questions

Question
I'm looking for a dual temp. and humidity gauge for an 8" duct. I'm wanting to remote read the temp and humidity on the incoming and outgoing air to an ERV unit. The RHP-3M11-LCD was recommended to me, however, it is a direct read. What would be the correct instrument to remote read the temperature and humidity from a distance of 8 feet. The 8" duct is in the attic and I want to read the result in the down-stair hall. I don't want to record nor program the unit, just read the performance.
Answer
The sensor recommended would be the best option we have for sensing temperature and relative humidity for your application. We do not have any options with a remote display that could stretch as far as you are asking, nor are there any on the market to my knowledge. In every case, you would need to utilize a process output, in this case 4-20 mA, to transmit the readings to a remote display(s) which would accept the process signal(s). If you are just looking for a remote readout to go with the RHP sensor with no control functionality, then you could look at one of our panel meters, possibly the SPPM, DPMA, DPMW, or DPMP & DPML series panel meters. For assistance selecting an appropriate panel meter, please contact our technical support group at 219-879-8000.
Question
P/N: RHP-2W44-LCD Documentation (https://dwyer-inst.com/PDF_files/AQ_RHP_E_N.pdf) on p. 4 indicates that sensor can be replaced, but unable to identify P/N of replacement sensor and if to be source from Dwyer or others
Answer
The replacement sensors are no longer available. RHP-2W44-LCD is now an obsolete unit that has been replaced with the RHP-2N44-LCD series. The sensors in this unit are not field replaceable.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-449 Remote display with mini USB display 1-3 days*
$68.60
SCD-PS 100 to 240 VAC/VDC to 24 VDC power supply 1-3 days*