Series AT-1800 ATEX/IECEx Approved Low Differential Pressure Switch

Series AT-1800 ATEX/IECEx Approved Low Differential Pressure Switch

Series AT-ADPS ATEX/IECEx Approved Differential Pressure Switch

Series AT-ADPS ATEX/IECEx Approved Differential Pressure Switch

Series 1950G Explosion-Proof Differential Pressure Switch

Explosion-proof, Weatherproof, Compatible with Natural Gases

Series 1950G Explosion-Proof Differential Pressure Switch combines the best features of the popular Dwyer® Series 1950 Pressure Switch with the benefit of natural gas compatibility. Units are rain-tight for outdoor installations, and are UL listed for use in Class I, Groups A, B, C, & D; Class II, Groups E, F, & G and Class III atmospheres, Directive 2014/34/EU (ATEX) Compliant for 2813 II 2G Ex db IIB+HT6, CSA & FM approved for Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G and Class III atmospheres. IECEx Ex db IIB+H T6 (-40°C<Ta<+60°C). The 1950G is very compact, about half the weight and bulk of equivalent conventional explosion-proof switches.
Easy access to the SPDT relay and power supply terminals is provided by removing the top plate of the aluminum housing. A supply voltage of 24 VDC, 120 or 240 VAC is required. A captive screw allows the cover to swing aside while remaining attached to the unit. Adjustment to the set point of the switch can be made without disassembly of the housing.

Product Applications

  • Natural gas applications
  • Process applications
  • All-weather applications
Starting at $564.60
Filter By
Grouped product items
Model Description Availability* Qty Price
1950G-0-B-120-NA Explosion-proof differential pressure switch, range .15-.50" w.c., approx. deadband @ min. set point .06, approx. deadband @ max. set point .11. 1-3 days*
$564.60
1950G-00-B-120-NA Explosion-proof differential pressure switch, range .07-.15" w.c., approx. deadband @ min. set point .04, approx. deadband @ max. set point .06. 1-3 days*
$564.60
1950G-1-B-120-NA Explosion-proof differential pressure switch, range .4-1.6" w.c., approx. deadband @ min. set point .11, approx. deadband @ max. set point .29 1-3 days*
$564.60
1950G-5-B-120-NA Explosion-proof differential pressure switch, range 1.4-5.5" w.c., approx. deadband @ min. set point .4, approx. deadband @ max. set point .9. 1-3 days*
$564.60
1950G-10-B-120-NA Explosion-proof differential pressure switch, range 3-11" w.c., approx. deadband @ min. set point .9, approx. deadband @ max. set point 1.8. 1-2 Weeks*
$564.60
1950G-20-B-120-NA Explosion-proof differential pressure switch, range 4-20" w.c., approx. deadband @ min. set point 1.2, approx. deadband @ max. set point 3.0. 1-3 days*
$564.60
1950G-0-B-24-NA Explosion-proof differential pressure switch, range .15-.50" w.c., approx. deadband @ min. set point .06, approx. deadband @ max. set point .11. 1-3 days*
$564.60
1950G-00-B-24-NA Explosion-proof differential pressure switch, range .07-.15" w.c., approx. deadband @ min. set point .04, approx. deadband @ max. set point .06. 1-3 days*
$564.60
1950G-1-B-24-NA Explosion-proof differential pressure switch, range .4-1.6" w.c., approx. deadband @ min. set point .11, approx. deadband @ max. set point .29. 1-3 days*
$564.60
1950G-5-B-24-NA Explosion-proof differential pressure switch, range 1.4-5.5" w.c., approx. deadband @ min. set point .4, approx. deadband @ max. set point .9. 1-3 days*
$564.60
1950G-10-B-24-NA Explosion-proof differential pressure switch, range 3-11" w.c., approx. deadband @ min. set point .9, approx. deadband @ max. set point 1.8. 1-3 days*
$564.60
1950G-20-B-24-NA Explosion-proof differential pressure switch, range 4-20" w.c., approx. deadband @ min. set point 1.2, approx. deadband @ max. set point 3.0. 1-3 days*
$564.60