Representative image displayed of PMT2-03-A-U2|Actual product may vary

PMT2-03-A-U2

Series PMT2 Particulate Transmitter

Digital Damping, Non-Stick Probe, For Broken Bag Detection

The Series PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current that is generated as particulate passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit the application. The range and test selector switch can also be set to output a 4 mA or 20 mA signal to assist with set up or trouble shooting. Averaging time setting can be used to dampen the signal if desired.

Product Applications

  • Emissions monitoring
  • Broken bag detection in dust collectors
  • Filter leak or wear detection
  • Bin vent monitoring
Starting at $2,422.15
Grouped product items
Model Description Availability* Qty Price
PMT2-03-A-U2 Particulate transmitter, 3" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-2 Weeks*
$2,422.15
PMT2-05-A-U2 Particulate transmitter, 5" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-2 Weeks*
$2,422.15
PMT2-10-A-U2 Particulate transmitter, 10" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-3 days*
$2,422.15
PMT2-15-A-U2 Particulate transmitter, 15" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-2 Weeks*
$2,718.55
PMT2-20-A-U2 Particulate transmitter, 20" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-3 days*
$2,718.55
PMT2-30-A-U2 Particulate transmitter, 30" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-2 Weeks*
$3,007.65
PMT2-36-A-U2 Particulate transmitter, 36" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections 1-2 Weeks*
$3,007.65

Specifications

Service:
Air and compatible gases, any type of particulate conductive or nonconductive.
Wetted Materials:
316L SS, silicone, and PTFE.
Enclosure:
Powder coated aluminum.
Accuracy:
±5% of reading.
Particulate Size:
0.3 microns and higher.
Detection Range:
5 to 5000 pA (6 selectable range options).
Temperature Limits:
Ambient: -40 to 145°F (-40 to 63°C); Process: -40 to 248°F (-40 to 120°C).
Pressure Limit:
30 psi (2 bar).
Output Signal:
4 to 20 mA.
Power Requirements:
12 to 28 VDC.
Electrical Connection:
Two 1/2" female NPT conduit openings.
Terminal Block:
Removable (16 to 20 AWG wire).
Process Connection:
See model chart on catalog page.
Probe Lengths:
See model chart on catalog page.
Enclosure Rating:
UL Type 4 (IP66), ATEX/IECEx IP65.
Mounting Orientation:
Any.
Averaging Time:
1 to 360 s (10 selectable options).
Weight:
Varies with length of probe and type of mount.
Compliance:
CE, cULus; ATEX Compliant: 2813 II 1 G Ex ia IIB T4 GA (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C) / II 1 D Ex ia IIIC T120°C Da (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C). Type Certificate No.: DEMKO 16ATEX1768 X. ATEX Standards: EN 60079-0:2012/A11:2013; EN 60079-11:2012. IECEx Certified: Ex ia IIB T4 Ga (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C) / Ex ia IIIC T120°C Da (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C). Certificate of Conformity: IECEx UL 16.013X. IECEx Standards: IEC 60079-0: 2011; IEC 60079-11: 2011. UL Listed Intrinsically Safe for Class I, Groups C and D; Class II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex ia IIB T4 Ga.

Features

  • Simple 2-wire installation for PLC and control panels
  • Non-stick PTFE coated probe to prevent false readings from moist and conductive dusts, condensate, and dust buildup
  • Remote zero calibration helps to decrease maintenance time

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Model Chart

EXAMPLE PMT2 03 A U2 ST Series PMT2-03-A-U2-ST, Particulate transmitter, 3" probe length, 3/4" male NPT, UL (intrinsically safe) with a stainless steel tag
SERIES PMT2         Particulate Transmitter
PROBE LENGTH   03
05
10
15
20
30
36
 
      3" Probe length
5" Probe length
10" Probe length
15" Probe length
20" Probe length
30" Probe length
36" Probe length
 
PROCESSS CONNECTION     A
B
C
    3/4" male NPT
1.5" tri-clamp kit with 1" male NPT
3/4" male BSPT
ENCLOSURE RATING       A2
U2
  ATEX intrinsically safe
UL intrinsically safe
OPTIONS         ST
M20
Stainless steel tag
Female M20 electrical entries
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-PMT2-M20 1/2" NPT to M20 conduit adapter Less Than 1 Week*
$74.35
A-PMT2-FLG 2" ANSI flange with 3/4" female NPT connection Less Than 1 Week*
$576.15