We use cookies to make your experience better. By using our site, you consent to cookies. Learn more.
Series 40T2 Digital Temperature Controller
Universal Sensor Input with Relay
The Series 40T2 Digital Temperature Controller accepts a variety of inputs for temperature measurements and set points up to 999°F/537°C. Observing the current status of the controller is made easier with the 3-digit, multi-color LED display that has alarm and output symbols. For added versatility, the temperature units can be field selected for °F or °C. A flashing alarm informs users when the current temperature exceeds preset limits. The Modbus® protocol TTL slave port can be used to communicate over a TTL/RS-485 interface. When programming multiple units, the 40X2-K programming key is available to reduce setup time.
Product Applications
- Food service equipment
- Industrial process control
Starting at $75.00
Specifications
- Sensor Input:
- RTD, thermocouple, thermistor, current, or voltage. 1 digital multipurpose dry contact (not available if unit configured fo Pt 100, Pt 1000, or Ni 120 3-wire input).
- Multipurpose Input:
- Dry contact 3.3V, 1 mA (not available if sensor input is configured for Pt 100, Pt 1000, or Ni 120 3-wire input).
- Sensor Input Types:
- Current: 0-20 mA/4-20 mA, configurable; Voltage: 0-10 V/2-10 V, configurable; PTC probe: -58 to 302°F (-50 to 150°C); NTC probe: -40 to 230°F (-40 to 110°C); PT100 probe*: -148 to 999°F (-100 to 650°C); PT1000 probe*: -148 to 999°F (-100 to 650°C); Ni120 probe: -112 to 572°F (-80 to 300°C); J T/C*: -130 to 999°F (-90 to 700°C); K T/C*: -130 to 999°F (-90 to 999°C). *Upper range limited by 3-digit display.
- Output:
- Relay contact.
- Control Type:
- On-off.
- Power Requirements:
- 115 VAC or 230 VAC (50/60 Hz), or 12-24 VAC/DC (50/60 Hz) depending on model.
- Accuracy:
- ±2°F (1°C).
- Communication:
- TTL/RS-485 interface, Modbus® protocol port for programming or BMS.
- Display:
- 3 digit LED display.
- Relay Output:
- K1 16 A in rush res. @ 250 VAC, SPDT, type 1.
- Alarm:
- Built-in buzzer.
- Operating Humidity:
- 10-90% RH non-condensing.
- Operating Temperature:
- 23 to 131°F (-5 to 55°C).
- Storage Temperature:
- -13 to 158°F (-25 to 70°C).
- Weight:
- 2.3 oz (65 g).
- Front Panel Rating:
- IP65.
- Compliance:
- CE, UKCA, cURus.
Features
- Field selectable °F or °C
- Universal temperature sensor or transmitter input
- Configuration key to quickly load parameters from one unit to another
- Heating and cooling operation modes
- TTL/RS-485 communication
Product Literature
Manuals
Catalog Pages
Product Data Sheet
Write Your Own Review
Model | Description | Availability* | Price | |
---|---|---|---|---|
TCS-J | J type thermocouple, 4" probe, 48" extension | 1-3 days* |
$30.20 |
|
TCS-K | K type thermocouple, 4" probe, 48" extension | 1-3 days* |
$25.55 |
|
TS-1 | PTC sensor, brass sheath, PVC cable, 5 ft. (1.5 m) length | 1-3 days* |
$11.90 |
|
TS-2 | PTC sensor, SS sheath, PVC cable, 5 ft (1.5 m) length | 1-3 days* |
$18.10 |
|
TS-7 | NTC sensor, no sheath, PVC cable, 5 ft (1.5 m) length | 1-3 days* |
$7.95 |