Series Mark II Molded Plastic Manometers

Series Mark II Molded Plastic Manometers

Series 1230/1235 Flex-Tube® Well-Type Manometers

Series 1230/1235 Flex-Tube® Well-Type Manometers

Series 200 & 300 Durablock® Solid Plastic Stationary Gage

Suitable for Total Pressures Up to 100 psig, Temperatures Up to 150°F, Accuracy ±2% of Full Scale (1% on Models 215, 244, 246 Only)

Dwyer® Series 200 & 300 Durablock® Solid Plastic Stationary Gages, or draft gages, are offered in inclined and vertical (well-type) styles for highly accurate laboratory or general industrial service, for measurement of low range gas and air pressures, positive, negative or differential. To assure the accuracy required in instruments of this type, all machining of bores and wells is to the highest standards of precision backed by Dwyer’s years of experience in the fabrications of acrylic instruments.

NIST CALIBRATION available in Product Configurator.

Click here, if you require a Safety Data Sheet for the Red Gage Fluid.

Product Applications

  • Low pressure laboratory and industrial service applications
Starting at $813.30
Filter By
Grouped product items
Model Description Availability* Qty Price
215 Solid plastic stationary gage, range .05-0-.25" w.c., .005 minor div., 6" scale, 2 lb 14 oz. 1-3 days*
$897.55

Features

  • 1" Thick Acrylic Plastic Body is a solid block, virtually unbreakable, stable and free of the danger of distortion.
  • Drilled Bore Accurate to ±.0002" free of bends or crooks, will not require recalibration because of distortion.
  • Selected Gage Fluid with high wetability characteristics forms a consistent, well shaped meniscus for most accurate readability.
  • Adjustable Reflective Polished Aluminum Scales with thumbscrew locking for easy zeroing.
  • Parallax-Free Reading for maximum accuracy and consistency is achieved by simply aligning the meniscus with its image reflected in the scale.
  • Over-Pressure Safety Traps prevent loss of fluid due to over range pressures or surges in pressure. (Not required on No. 215.)
  • Leveling Adjustment for inclined style gages is achieved by simply loosening a locking thumb screw on the side or bottom of the gage, adjusting with reference to the integral sensitive ground glass bubble level and retightening.
  • Heavy Gage Steel Mounting Panels are gray hammerloid finished.
  • Precision Built assures device meets the highest standards
  • Standard units have the A-315 3/16" ID tubing connectors, more connection options in the product configurator.

Options

  • Type B connections (Two molded nylon rapid shutoff tubing connectors, one 9 foot length of rubber tubing and one brass terminal tube).
  • Type C connections (Two 1/8" pipe thread openings).
  • Type D connections(Two compression fittings for 1/4" O.D. copper or aluminum tubing).
  • Type E connections (Two 3-way vent valves, 1/8" 1/8 NPT to 1/4" metal tubing).
  • -AT Aluminum Tag (Useful for identifying where the product goes in a large facility).
  • -NIST Nist Calibration

Model Chart

EXAMPLE 200 -B Series 200 Durablock® Solid Plastic Stationary Gage, inclined, range 0.1-0-1" w.c., with type B connections.
MANOMETER TYPE 200
200.5
201
202
202.5
209
215
244
246
300
306
308
310
M200
M200.5
M201
M202
M202.5
M209
M215
M246
M300
M306
M308
M310
  Inclined, 0.1-0-1" w.c.
Inclined, 0.1-0-1" w.c.
Inclined, .05-0.5" w.c.
Inclined, 0.2-0-2" w.c.
Inclined, 0.2-0-2" w.c.
Inclined, 0.2-0-3" w.c.
Inclined, 0 .05-0-0.25" w.c.
Inclined, 0-4" w.c.
Inclined, 0-6" w.c.
Vertical, 0-4" w.c.
Vertical, 0-6" w.c.
Vertical, 0-8" w.c.
Vertical, 0-10" w.c.
Inclined, 3-0-25 mm w.c.
Inclined, 3-0-25 mm w.c.
Inclined, 0-15 mm w.c.
Inclined, 5-0-50 mm w.c.
Inclined, 5-0-50 mm w.c.
Inclined, 5-0-75 mm w.c.
Inclined, 2-0-6 mm w.c.
Inclined, 0-150 mm w.c.
Vertical, 0-11 cm w.c.
Vertical, 0-16.4 cm w.c.
Vertical, 0-21.6 cm w.c.
Vertical, 0-25 cm w.c.
OPTIONS   -B
-C
-D
-E
-AT
-NIST
Type B Connections
Type C Connections
Type D Connections
Type E Connections
Aluminum Tag
NIST Calibration

Questions

Question
Is routine maintenance required for a Dwyer red gage fluid type manometer?
Answer
Yes. The zero point should be checked periodically as well as the fluid level. After a year of service, particularly with dirty air, the fluid should be replaced to assure that specific gravity changes are not affecting the accuracy of the reading.
Question
Does the model 310 manometer require regular calibration and if so, what calibration interval is recommended? Also, if calibration is required, do you have a location which could perform the calibration?
Answer
The Model 310 manometer does not require any calibration, as long as there has been no physical damage to the gauge. So barring no leaks or cracks, no calibration is needed. We do recommend changing out the gauge fluid every 3 years to ensure proper functionality.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-101 1 oz dispenser bottle of red gage fluid, .826 sp. gr. 1-3 days*
$10.85
A-102 4 oz bottle of red gage fluid, .826 sp. gr. 1-3 days*
$21.15
A-103 1 pt bottle of red gage fluid, .826 sp. gr. 1-3 days*
$46.95
A-104 1 qt bottle of red gage fluid, .826 sp. gr. 1-3 days*
$88.25
A-220 Clear flexible vinyl tubing, 3/16" ID x 5/16" OD, lengths to 500'; 45 psi maximum pressure @ 73°F. 1-3 days*
$0.50
A-315 Gage connector, shutoff type, for 3/16" rubber tubing. 1-3 days*
$19.10
A-339 Adapter, brass, 1/8" NPT to 3/16" rubber and 1/8" ID plastic tubing. 1-3 days*
$5.55