Series 4000 Capsuhelic® Differential Pressure Gage
The Series 4000 Capsuhelic® Differential Pressure Gage is designed to give fast, accurate indication of differential pressures. The gage may be used as a readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure, vacuum or differential pressure. The pressure being measured is held within a capsule which is an integral part of the gage. This containment of the pressure permits the use of the gage on system pressures of up to 500 psig, even when differentials to be read are less than 0.1 in w.c.
Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.
NIST CALIBRATION available in Product Configurator.
DID YOU KNOW that you can add YOUR logo to our Capsuhelic® Gage, call customer service for details.
Product Applications
- Fluid flow
- Liquid storage tanks
- Filter pressure drops
- Vacuum or differential pressure
Specifications
- Service:
- Aluminum Case: Air and compatible gases and oil based liquids. Brass Case: Air and compatible gases and water based liquids.
- Wetted Materials:
- Consult factory.
- Housing:
- Die cast aluminum with impregnated hard coating, standard. Optional forged brass housing is required for water or water based fluids.Special material diaphragms available, contact factory.
- Accuracy:
- ±3% of FS at 70°F (21.1°C). (±4% on 4200, 4210, 4215, 4220, 4300, 4400, and 4500).
- Pressure Limits:
- -20" Hg to 500 psig. (-0.677 bar to 34.4 bar).
- Temperature Limits:
- 20 to 200°F (-6.67 to 93.3°C).
- Size:
- 4" (101.6 mm) diameter dial face.
- Mounting Orientation:
- Diaphragm in vertical position. Consult factory for other position orientations.
- Process Connections:
- 1/4" female NPT high and low pressure taps, duplicated - one pair top for air and gas, and one pair bottom for liquids.
- Weight:
- 3 lb, 3 oz (1.45 kg) aluminum case; 7 lb, 13 oz (3.54 kg) brass case.
- Standard Accessories:
- Two 1/4" NPT plugs for duplicate pressure taps, four flush mounting adapters with screws and four surface mounting screws.
Features
- Gage capsule permits high-pressure usage with small differentials
- Zero and range adjustments outside of gage means no disassembly in normal service
- Time-proven, simple, frictionless movement that permits full scale readings as low as 0.5 in w.c.
- Diaphragm-actuated versus liquid filled gage supports outdoor use
Options
- ASF - Adjustable Signal Flag
- B - Brass Case
- NIST - Traceable calibration certificate
- Scale Overlays - Red, Green, Mirrored or Combination; specify locations
Model Chart
EXAMPLE | 4000 | B | -0 | ASF | Series 4000B-0-ASF Capsuhelic® differential Pressure Gage, range 0-0.5" w.c., brass case, with adjustable signal flag. |
BRASS CASE | B | Brass Case for Water or Water Based Liquids | |||
RANGE |
4000 4001 4002 4003 4004 4005 4006 4008 4010 4015 4020 4025 4030 4040 4050 4060 4080 4100 4150 4200 4300 4400 4500 4302 4304 4310 4320 4330 4201 4202 4203 4204 4205 4210 4215 4220 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4300 4300 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4300 4300 4300 4300 4000 4000 4000 4000 4000 4300 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4300 4300 4000 4000 4000 4000 4000 4300 4300 |
-0 -20FT -5HG -10HG -15HG -20HG -25HG -30HG -40HG -100MMHG -200MMHG -15MM -20MM -25MM -30MM -40MM -50MM -80MM -100MM -150MM -200MM -250MM -300MM -30MM -100MM -2CM -5CM -8CM -10CM -15CM -20CM -25CM -30CM -40CM -50CM -80CM -100CM -150CM -200CM -250CM -300CM -500CM -4CM -10CM -20CM -30CM -125PA -250PA -300PA -500PA -750PA -500PA -1KPA -1.5KPA -2KPA -3KPA -4KPA -5KPA -8KPA -10KPA -15KPA -20KPA -25KPA -30KPA -50KPA -100KPA -1KPA -3KPA -20MBAR -50MBAR -80MBAR -100MBAR -250MBAR -10MBAR -30MBAR |
0-0.5" w.c. 0-1" w.c. 0-2" w.c. 0-3" w.c. 0-4" w.c. 0-5" w.c. 0-6" w.c. 0-8" w.c. 0-10" w.c. 0-15" w.c. 0-20" w.c. 0-25" w.c. 0-30" w.c. 0-40" w.c. 0-50" w.c. 0-60" w.c. 0-80" w.c. 0-100" w.c. 0-150" w.c. 0-200" w.c. 0-300" w.c. 0-400" w.c. 0-500" w.c. 1-0-1" w.c. 2-0-2" w.c. 5-0-5" w.c. 10-0-10" w.c. 15-0-15" w.c. 0-1 psid 0-2 psid 0-3 psid 0-4 psid 0-5 psid 0-10 psid 0-15 psid 0-20 psid 0-20' w.c. 0-5" Hg 0-10" Hg 0-15" Hg 0-20" Hg 0-25" Hg 0-30" Hg 0-40" Hg 0-100 mm Hg 0-200 mm Hg 0-15 mm w.c. 0-20 mm w.c. 0-25 mm w.c. 0-30 mm w.c. 0-40 mm w.c. 0-50 mm w.c. 0-80 mm w.c. 0-100 mm w.c. 0-150 mm w.c. 0-200 mm w.c. 0-250 mm w.c. 0-300 mm w.c. 15-0-15 mm w.c. 50-0-50 mm w.c. 0-2 cm w.c. 0-5 cm w.c. 0-8 cm w.c. 0-10 cm w.c. 0-15 cm w.c. 0-20 cm w.c. 0-25 cm w.c. 0-30 cm w.c. 0-40 cm w.c. 0-50 cm w.c. 0-80 cm w.c. 0-100 cm w.c. 0-150 cm w.c. 0-200 cm w.c. 0-250 cm w.c. 0-300 cm w.c. 0-500 cm w.c. 2-0-2 cm w.c. 5-0-5 cm w.c. 10-0-10 cm w.c. 15-0-15 cm w.c. 0-125 Pa 0-250 Pa 0-300 Pa 0-500 Pa 0-750 Pa 250-0-250 Pa 0-1 kPa 0-1.5 kPa 0-2 kPa 0-3 kPa 0-4 kPa 0-5 kPa 0-8 kPa 0-10 kPa 0-15 kPa 0-20 kPa 0-25 kPa 0-30 kPa 0-50 kPa 0-100 kPa 0.5-0-0.5 kPa 1.5-0-1.5 kPa 0-20 mbar 0-50 mbar 0-80 mbar 0-100 mbar 0-250 mbar 5-0-5 mbar 15-0-15 mbar |
||
OPTIONS |
ASF AT BUNA VIT G HC LT M NIST R ST SPCL TA Y |
Adjustable Signal Flag Aluminum Tag Buna-N Diaphragm Fluoroelastomer Diaphragm Green Scale Overlay Horizontal Calibration Low Temperature Mirror Scale Overlay NIST Certificate of Calibration Red Scale Overlay Stainless Steel Tag Special Cleaning Tilt Angle from Vertical in Degrees (-90 to 90) Yellow Scale Overlay |
Questions
- Question
- Which Capsuhelic® gage ports could be connected to the pressure source in liquid service?
- Answer
- The bottom ports. This allows bleeding of entrapped air from the top ports to eliminate reading error due to compression of entrapped air in the gage. Bleed fittings should be installed in the top ports.
- Question
- Can the standard Magnehelic® or Capsuhelic® gage be installed outdoors?
- Answer
- Yes. Front covers are sealed with "O" rings. Capsuhelic vent holes are plugged with foam, and the new high impact acrylic lens material is very resistant to ultra-violet fogging. Additional care is recommended to lead pressure connections downward from the gage and provide as much protection from the elements as possible
- Question
- Why must Dwyer pressure switches be mounted with the diaphragm in the vertical plane?
- Answer
- In other than a vertical plane, the diaphragm can sag and cause a shift in set-point or a change in the adjustable set-point range. The switch may even fail to reset at the minimum set-points. This is the same phenomena that causes inaccuracy in Magnehelic® and Capsuhelic® gages when mounted in other than a vertical position.
- Question
- What might be the cause for Magnehelic® gages filling approximately 1/3 full of water, with lots of liquid droplets on the glass. Both are outside mounted on the side of an air stripping tower. One is a differential pressure gage that measures the pressure drop across a pitot tube. The other just measures the back pressure in the stripper. What can be done to fix the malfunction?
- Answer
- It looks like you’re getting some condensation in the Magnehelic®, which is causing it to collect on the bottom of the face. Since the Magnehelic® is not encapsulated, it is not recommended to be used in applications where moisture can form. One option to fix the problem is installing a liquid filter (like an F222) to filter out that moisture. Another option is to install a Capsuhelic (Series 4000), which is made to handle both air and liquid.
Model | Description | Availability* | Price | |
---|---|---|---|---|
A-298 | Flat aluminum bracket for flush mounting (for Series A3000 Photohelic®, Series 4000 Capsuhelic®, Series 605, and Series 3000MR) | 1-3 days* |
$37.65 |
|
A-370 | Flush mount bracket used with: Photohelic® 3000MR/MRS, Capsuhelic®, 631B Transmitter. Bracket is then surface mounted. Steel with gray hammertone epoxy finish. | 1-3 days* |
$45.40 |