Standard Magnehelic® (2001 shown)

Series 2000 Magnehelic® Differential Pressure Gages

Series 2000-SP Magnehelic® Differential Pressure Gages

Series 2000-SP Magnehelic® Differential Pressure Gages

Series 4000 Capsuhelic® Differential Pressure Gage

Measures Pressure, Vacuum or Differential, Suitable for Internal Pressures to 500 psig

The Series 4000 Capsuhelic® Differential Pressure Gage is designed to give fast, accurate indication of differential pressures. The gage may be used as a readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure, vacuum or differential pressure. The pressure being measured is held within a capsule which is an integral part of the gage. This containment of the pressure permits the use of the gage on system pressures of up to 500 psig, even when differentials to be read are less than 0.1 in w.c.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

NIST CALIBRATION available in Product Configurator.

DID YOU KNOW that you can add YOUR logo to our Capsuhelic® Gage, call customer service for details.

California Residents:  Click Here for Proposition 65 WARNING.

Product Applications

  • Fluid flow
  • Liquid storage tanks
  • Filter pressure drops
  • Vacuum or differential pressure
Starting at $772.70
Filter By
Grouped product items
Model Description Availability* Qty Price
4015 Differential pressure gage, range 0-15" w.c. 1-3 days*
$916.25
4025 Differential pressure gage, range 0-25" w.c. 3-4 Weeks*
$916.25
4030 Differential pressure gage, range 0-30" w.c. 1-3 days*
$916.25
4050 Differential pressure gage, range 0-50" w.c. 1-3 days*
$916.25

Specifications

Service:
Aluminum Case: Air and compatible gases and oil based liquids. Brass Case: Air and compatible gases and water based liquids.
Wetted Materials:
Consult factory.
Housing:
Die cast aluminum with impregnated hard coating, standard. Optional forged brass housing is required for water or water based fluids.Special material diaphragms available, contact factory.
Accuracy:
±3% of FS at 70°F (21.1°C). (±4% on 4200, 4210, 4215, 4220, 4300, 4400, and 4500).
Pressure Limits:
-20" Hg to 500 psig. (-0.677 bar to 34.4 bar).
Temperature Limits:
20 to 200°F (-6.67 to 93.3°C).
Size:
4" (101.6 mm) diameter dial face.
Mounting Orientation:
Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections:
1/4" female NPT high and low pressure taps, duplicated - one pair top for air and gas, and one pair bottom for liquids.
Weight:
3 lb, 3 oz (1.45 kg) aluminum case; 7 lb, 13 oz (3.54 kg) brass case.
Standard Accessories:
Two 1/4" NPT plugs for duplicate pressure taps, four flush mounting adapters with screws and four surface mounting screws.

Features

  • Gage capsule permits high-pressure usage with small differentials
  • Zero and range adjustments outside of gage means no disassembly in normal service
  • Time-proven, simple, frictionless movement that permits full scale readings as low as 0.5 in w.c.
  • Diaphragm-actuated versus liquid filled gage supports outdoor use

Options

  • ASF - Adjustable Signal Flag
  • B - Brass Case
  • NIST - Traceable calibration certificate
  • Scale Overlays - Red, Green, Mirrored or Combination; specify locations

Product Literature

Manuals

Catalog Pages

Model Chart

 
EXAMPLE 4000 B -0 ASF Series 4000B-0-ASF Capsuhelic® differential Pressure Gage, range 0-0.5" w.c., brass case, with adjustable signal flag.
BRASS CASE   B     Brass Case for Water or Water Based Liquids
RANGE 4000
4001
4002
4003
4004
4005
4006
4008
4010
4015
4020
4025
4030
4040
4050
4060
4080
4100
4150
4200
4300
4400
4500
4302
4304
4310
4320
4330
4201
4202
4203
4204
4205
4210
4215
4220
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4300
4300
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4300
4300
4300
4300
4000
4000
4000
4000
4000
4300
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4300
4300
4000
4000
4000
4000
4000
4300
4300
  -0



































-20FT
-5HG
-10HG
-15HG
-20HG
-25HG
-30HG
-40HG
-100MMHG
-200MMHG
-15MM
-20MM
-25MM
-30MM
-40MM
-50MM
-80MM
-100MM
-150MM
-200MM
-250MM
-300MM
-30MM
-100MM
-2CM
-5CM
-8CM
-10CM
-15CM
-20CM
-25CM
-30CM
-40CM
-50CM
-80CM
-100CM
-150CM
-200CM
-250CM
-300CM
-500CM
-4CM
-10CM
-20CM
-30CM
-125PA
-250PA
-300PA
-500PA
-750PA
-500PA
-1KPA
-1.5KPA
-2KPA
-3KPA
-4KPA
-5KPA
-8KPA
-10KPA
-15KPA
-20KPA
-25KPA
-30KPA
-50KPA
-100KPA
-1KPA
-3KPA
-20MBAR
-50MBAR
-80MBAR
-100MBAR
-250MBAR
-10MBAR
-30MBAR
  0-0.5" w.c.
0-1" w.c.
0-2" w.c.
0-3" w.c.
0-4" w.c.
0-5" w.c.
0-6" w.c.
0-8" w.c.
0-10" w.c.
0-15" w.c.
0-20" w.c.
0-25" w.c.
0-30" w.c.
0-40" w.c.
0-50" w.c.
0-60" w.c.
0-80" w.c.
0-100" w.c.
0-150" w.c.
0-200" w.c.
0-300" w.c.
0-400" w.c.
0-500" w.c.
1-0-1" w.c.
2-0-2" w.c.
5-0-5" w.c.
10-0-10" w.c.
15-0-15" w.c.
0-1 psid
0-2 psid
0-3 psid
0-4 psid
0-5 psid
0-10 psid
0-15 psid
0-20 psid
0-20' w.c.
0-5" Hg
0-10" Hg
0-15" Hg
0-20" Hg
0-25" Hg
0-30" Hg
0-40" Hg
0-100 mm Hg
0-200 mm Hg
0-15 mm w.c.
0-20 mm w.c.
0-25 mm w.c.
0-30 mm w.c.
0-40 mm w.c.
0-50 mm w.c.
0-80 mm w.c.
0-100 mm w.c.
0-150 mm w.c.
0-200 mm w.c.
0-250 mm w.c.
0-300 mm w.c.
15-0-15 mm w.c.
50-0-50 mm w.c.
0-2 cm w.c.
0-5 cm w.c.
0-8 cm w.c.
0-10 cm w.c.
0-15 cm w.c.
0-20 cm w.c.
0-25 cm w.c.
0-30 cm w.c.
0-40 cm w.c.
0-50 cm w.c.
0-80 cm w.c.
0-100 cm w.c.
0-150 cm w.c.
0-200 cm w.c.
0-250 cm w.c.
0-300 cm w.c.
0-500 cm w.c.
2-0-2 cm w.c.
5-0-5 cm w.c.
10-0-10 cm w.c.
15-0-15 cm w.c.
0-125 Pa
0-250 Pa
0-300 Pa
0-500 Pa
0-750 Pa
250-0-250 Pa
0-1 kPa
0-1.5 kPa
0-2 kPa
0-3 kPa
0-4 kPa
0-5 kPa
0-8 kPa
0-10 kPa
0-15 kPa
0-20 kPa
0-25 kPa
0-30 kPa
0-50 kPa
0-100 kPa
0.5-0-0.5 kPa
1.5-0-1.5 kPa
0-20 mbar
0-50 mbar
0-80 mbar
0-100 mbar
0-250 mbar
5-0-5 mbar
15-0-15 mbar
OPTIONS       ASF
AT
BUNA
VIT
G
HC
LT
M
NIST
R
ST
SPCL
TA
Y
Adjustable Signal Flag
Aluminum Tag
Buna-N Diaphragm
Fluoroelastomer Diaphragm
Green Scale Overlay
Horizontal Calibration
Low Temperature
Mirror Scale Overlay
NIST Certificate of Calibration
Red Scale Overlay
Stainless Steel Tag
Special Cleaning
Tilt Angle from Vertical in Degrees (-90 to 90)
Yellow Scale Overlay

Questions

Question
Which Capsuhelic® gage ports could be connected to the pressure source in liquid service?
Answer
The bottom ports. This allows bleeding of entrapped air from the top ports to eliminate reading error due to compression of entrapped air in the gage. Bleed fittings should be installed in the top ports.
Question
Can the standard Magnehelic® or Capsuhelic® gage be installed outdoors?
Answer
Yes. Front covers are sealed with "O" rings. Capsuhelic vent holes are plugged with foam, and the new high impact acrylic lens material is very resistant to ultra-violet fogging. Additional care is recommended to lead pressure connections downward from the gage and provide as much protection from the elements as possible
Question
Why must Dwyer pressure switches be mounted with the diaphragm in the vertical plane?
Answer
In other than a vertical plane, the diaphragm can sag and cause a shift in set-point or a change in the adjustable set-point range. The switch may even fail to reset at the minimum set-points. This is the same phenomena that causes inaccuracy in Magnehelic® and Capsuhelic® gages when mounted in other than a vertical position.
Question
What might be the cause for Magnehelic® gages filling approximately 1/3 full of water, with lots of liquid droplets on the glass. Both are outside mounted on the side of an air stripping tower. One is a differential pressure gage that measures the pressure drop across a pitot tube. The other just measures the back pressure in the stripper. What can be done to fix the malfunction?
Answer
It looks like you’re getting some condensation in the Magnehelic®, which is causing it to collect on the bottom of the face. Since the Magnehelic® is not encapsulated, it is not recommended to be used in applications where moisture can form. One option to fix the problem is installing a liquid filter (like an F222) to filter out that moisture. Another option is to install a Capsuhelic (Series 4000), which is made to handle both air and liquid.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-298 Flat aluminum bracket for flush mounting (for Series A3000 Photohelic®, Series 4000 Capsuhelic®, Series 605, and Series 3000MR) 1-3 days*
$37.65
A-370 Flush mount bracket used with: Photohelic® 3000MR/MRS, Capsuhelic®, 631B Transmitter. Bracket is then surface mounted. Steel with gray hammertone epoxy finish. 1-3 days*
$45.40
A-610 Pipe mounting kit for 1-1/4" to 2" pipe. 5.6" x 4.6" x 1.4", 1.0 .lb (Magnehelic® sold separately) 1-3 days*
$36.65