Series CDWP Carbon Dioxide Transmitter

Series CDWP Carbon Dioxide Transmitter

Model CDSN Carbon Dioxide Transmitter

Model CDSN Carbon Dioxide Transmitter

Series CDTC Communicating Carbon Dioxide Sensor

NDIR CO2 Sensor, Measures CO2, Temperature, Temperature Set Point with Override

The Series CDTC Communicating Carbon Dioxide Sensor combines the function of two room sensors into a single, compact housing. Parameters include carbon dioxide, temperature, and temperature set point with override. A 4-wire connection and daisy chaining together reduces installation cost. The RS-485 MAC address is set up using on-board DIP switches. Additional DIP switches are used to select Modbus® RTU or BACnet MS/TP and to limit access to the set up menu. The barometric pressure can be programmed to correct for altitude. Optional integral display is available to display temperature, or temperature set point instead of CO2.
*For environments occupied 24 hours per day it is recommended to periodically expose the CO2 sensor to outside ambient air.

Product Applications

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED® certification
Starting at $299.50
Grouped product items
Model Description Availability* Qty Price
CDTC-2N000 Communicating carbon dioxide transmitter with temperature output, 2000 PPM range and North American housing 1-3 days*
$299.50
CDTC-2N000-LCD Communicating carbon dioxide transmitter with temperature output, 2000 PPM range, North American housing and LCD display 1-2 Weeks*
$362.95
CDTC-5N000 Communicating carbon dioxide transmitter with temperature output, 5000 PPM range and North American housing 1-2 Weeks*
$299.50
CDTC-5N000-LCD Communicating carbon dioxide transmitter with temperature output, 5000 PPM range, North American housing and LCD display 1-2 Weeks*
$362.95

Specifications

Range:
0 to 2000 or 5000 PPM CO2 (depending on model); 32 to 122°F (0 to 50°C) temperature.
Accuracy:
±40 PPM ±3% of reading carbon dioxide; Temperature: ± 1°C @ 25°C.
Response Time :
<2 minutes, diffusion, carbon dioxide.
Sensor Technology:
NDIR (non-dispersive infrared); 15 year light source.
Temperature Limits:
32 to 122°F (0 to 50°C).
Output:
2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol.
Humidity Limits:
10 to 95% RH (non-condensing).
Power Requirements:
10-42 VDC or 10-30 VAC.
Weight:
4.4 oz (125 g).
Compliance:
BTL, CE.

Features

  • Minimize inventory and save time by combining CO2 and temperature measurements into one transmitter
  • Reduces the number of devices mounted in the space with integral temperature sensing
  • Requires minimal maintenance with Automatic Baseline Correction (ABC) to account for sensor drift
  • Field selectable Modbus® and BACnet communications reduces wiring
  • Simplify installation with backplate electrical connection

Options

  • -FC Factory calibration certificate offered in configurator

Product Literature

Manuals

Catalog Pages

Product Data Sheet

SlideShare

Model Chart

CDTC-XXXXX-OPT    CDT CARBON DIOXIDE DETECTOR
 
          1ST SYMBOL (1ST X) RANGE
             2    2000 PPM
             5    5000 PPM
 
          2ND SYMBOL (2ND X) HOUSING 
             N    NORTH AMERICAN
 
          3RD SYMBOL (3RD X) CO2 OUTPUT 
             0    NONE
 
          4TH SYMBOL (4TH X) TEMPERATURE OUTPUT 
             0    NONE
 
          5TH SYMBOL (5TH X) RH OUTPUT 
             0    NONE
 
          OPTIONS (OPT) 
            -LCD  LIQUID CRYSTAL DISPLAY
            -COC  CERTIFICATE OF CALIBRATION
            -FC   FACTORY CALIBRATION CERTIFICATE
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
GCK-200CO-2000CO2 Gas Calibration Kit (GROUND SHIPMENTS ONLY) 1-3 days*
$726.55
A-449 Remote display with mini USB display 1-3 days*
$68.60
A-CDT-KIT Accessory kit including terminal block and power supply. 1-2 Weeks*
$55.15