Series 4000 Capsuhelic® Differential Pressure Gage

Series 4000 Capsuhelic® Differential Pressure Gage

Series DM-1000 DigiMag® Digital Differential Pressure and Flow Gages

Series DM-1000 DigiMag® Digital Differential Pressure and Flow Gages

Series 2000-SP Magnehelic® Differential Pressure Gages

Indicate Positive, Negative or Differential, Accurate within 2%

Series 2000-SP Magnehelic® Differential Pressure Gage has a bright red LED on the right of the scale showing when setpoint is reached. Field adjustable from gage face, unit operates on 12-24 VDC. Requires MP or HP style cover and bezel.

NIST CALIBRATION available in Product Configurator.

Starting at $267.30
Grouped product items
Model Description Availability* Qty Price
2000-0-SP Differential pressure gage, range 0-0.50" w.c., with set point indicator, ±3% accuracy. Less Than 1 Week*
$267.30
2001-SP Differential pressure gage, range 0-1" w.c., with set point indicator. Less Than 1 Week*
$267.30
2002-SP Differential pressure gage, range 0-2" w.c., with set point indicator. Less Than 1 Week*
$267.30
2005-SP Differential pressure gage, range 0-5" w.c., with set point indicator. Less Than 1 Week*
$267.30
2010-SP Differential pressure gage, range 0-10" w.c., with set point indicator. Less Than 1 Week*
$267.30

Specifications

Service:
Air and non-combustible, compatible gases. (Natural gas option available.)
Wetted Materials:
Consult factory.
Housing:
Die cast aluminum case and bezel, with acrylic cover. Exterior finish is coated gray to withstand 168 hour salt spray corrosion test.
Accuracy:
±2% of full scale (±3% on - 0, -100 Pa, -125 Pa, 10MM and ±4% on - 00,-60 Pa, -6MM ranges), throughout range at 70°F (21.1°C).
Pressure Limits:
35 psig (2.41 bar), HP option: 80 psig (5.52 bar).
Overpressure:
Relief plug opens at approximately 25 psig (1.72 bar), standard gages only.
Temperature Limits:
20 to 140°F. (-6.67 to 60°C).
Size:
4" (101.6 mm) diameter dial face.
Mounting Orientation:
Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections:
1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back.
Weight:
1 lb 2 oz (510 g), MP & HP 2 lb 2 oz (963 g).
Standard Accessories:
Two 1/8" NPT plugs for duplicate pressure taps, two 1/8" pipe thread to rubber tubing adapter and three flush mounting adapters with screws. (Mounting and snap ring retainer substituted for 3 adapters in MP & HP gage accessories.)

Product Literature

Manuals

Catalog Pages

Model Chart

EXAMPLE 2001 SP-AT Series 2001-SP-AT Magnehelic® Differential Pressure Gage, range 0-1" w.c., with set point indicator and aluminum tag.
RANGE 2000-00N
2000-00
2000-0
2001
2002
2003
2004
2005
2006
2008
2010
2015
2020
2025
2030
2040
2050
2060
2080
2100
2150
2300-0
2301
2302
2304
2310
2320
2330
2000-00AV
2000-0AV
2001AV
2002AV
2010AV
2201
2202
2203
2204
2205
2210
2215
2220
2230
2000-6MM
2000-10MM
2000-20MM
2000-25MM
2000-50MM
2000-80MM
2000-100MM
2000-150MM
2000-250MM
2300-20MM
2300-30MM
2000-1CM
2000-2CM
2000-5CM
2000-10CM
2000-15CM
2000-20CM
2000-25CM
2000-30CM
2000-40CM
2000-50CM
2000-80CM
2000-100CM
2000-150CM
2000-200CM
2000-250CM
2000-300CM
2300-4CM
2300-10CM
2300-20CM
2300-30CM
2000-60PA
2000-125PA
2000-250PA
2000-500PA
2000-750PA
2300-250PA
2300-500PA
2000-1KPA
2000-1.5KPA
2000-2KPA
2000-3KPA
2000-4KPA
2000-5KPA
2000-8KPA
2000-10KPA
2000-15KPA
2000-20KPA
2000-25KPA
2000-30KPA
2300-1KPA
2300-3KPA
  .05-0-.2" w.c.
0-0.2" w.c.
0-0.5" w.c.
0-1" w.c.
0-2" w.c.
0-3" w.c.
0-4" w.c.
0-5" w.c.
0-6" w.c.
0-8" w.c.
0-10" w.c.
0-15" w.c.
0-20" w.c.
0-25" w.c.
0-30" w.c.
0-40" w.c.
0-50" w.c.
0-60" w.c.
0-80" w.c.
0-100" w.c.
0-150" w.c.
.25-0-.25" w.c.
.5-0-.5" w.c.
1-0-1" w.c.
2-0-2" w.c.
5-0-5" w.c.
10-0-10" w.c.
15-0-15" w.c.
0-.25" w.c. & 300-2000 FPM AV
0-.5" w.c. & 500-2800 FPM AV
0-1" w.c. & 500-4000 FPM AV
0-2" w.c. & 1000-5600 FPM AV
0-10" w.c. & 2000-12500 FPM AV
0-1 psid
0-2 psid
0-3 psid
0-4 psid
0-5 psid
0-10 psid
0-15 psid
0-20 psid
0-30 psid
0-6 MM w.c.
0-10 MM w.c.
0-20 MM w.c.
0-25 MM w.c.
0-50 MM w.c.
0-80 MM w.c.
0-100 MM w.c.
0-150 MM w.c.
0-250 MM w.c.
10-0-10 MM w.c.
15-0-15 MM w.c.
0-1 CM w.c.
0-2 CM w.c.
0-5 CM w.c.
0-10 CM w.c.
0-15 CM w.c.
0-20 CM w.c.
0-25 CM w.c.
0-30 CM w.c.
0-40 CM w.c.
0-50 CM w.c.
0-80 CM w.c.
0-100 CM w.c.
0-150 CM w.c.
0-200 CM w.c.
0-250 CM w.c.
0-300 CM w.c.
2-0-2 CM w.c.
5-0-5 CM w.c.
10-0-10 CM w.c.
15-0-15 CM w.c.
0-60 Pa
0-125 Pa
0-250 Pa
0-500 Pa
0-750 Pa
125-0-125 Pa
250-0-250 Pa
0-1 kPa
0-1.5 kPa
0-2 kPa
0-3 kPa
0-4 kPa
0-5 kPa
0-8 kPa
0-10 kPa
0-15 kPa
0-20 kPa
0-25 kPa
0-30 kPa
.5-0-.5 kPa
1.5-0-1.5 kPa
OPTION   -AT
-COO
-ED
-G
-HC
-HP
-LT
-M
-MP
-NIST
-R
-SP
-ST
-TA
-TAMP
-Y
Aluminum Tag
Certificate of Origin
Energizing
Green Scale Overlay
Horizontal Calibration (90° Face Up)
High Pressure
Low Temperature
Mirror Scale Overlay
Medium Pressure
NIST Certificate of Calibration
Red Scale Overlay
Set Point Indicator
Stainless Steel Tag
Tilt Angle from Vertical in Degrees (-90 to 90)
Tamperproof Knobs
Yellow Scale Overlay

Questions

Question
How will installation of a Magnehelic® gage 150' away from the pressure source affect accuracy?
Answer
Accuracy will not be affected, but response time will be increased in proportion to the length of the tubing.
Question
Can the standard Magnehelic® or Capsuhelic® gage be installed outdoors?
Answer
Yes. Front covers are sealed with "O" rings. Capsuhelic vent holes are plugged with foam, and the new high impact acrylic lens material is very resistant to ultra-violet fogging. Additional care is recommended to lead pressure connections downward from the gage and provide as much protection from the elements as possible
Question
Can a standard Magnehelic® gage be used for natural gas or propane service?
Answer
No. As the silicone diaphragm will be attacked by these gases. A Buna-N diaphragm should be specified.
Question
What happens when a Magnehelic® gage equipped with the low temperature option is operated below -20 degrees Fahrenheit (-29 degrees Celsius)?
Answer
Below that temperature the accuracy of the gage deteriorates beyond our published specification due to stiffening of the diaphragm.
Question
Is National Institute of Standards and Technology traceability available for the Magnehelic® Gage?
Answer
No. But Magnehelic® gages can be given a special 6 point calibration check with an NIST traceable master gage and a certificate can be supplied.
Question
How do I hook up my Magnehelic® Gage?
Answer
In Bulletin A-27 under operation, it explains how to connect the Magnehelic to the following applications: positive pressure, negative pressure, and differential pressure.
Question
Your Magnehelic gauge doesn't come with a calibration certificate, do you have any documentation for these gauges to meet these needs?
Answer
We have 3 options: (1) We can supply a Certificate of Conformance at no charge if you request that certificate at the time of order. The Certificate of conformance would state that each Magnehelic gauge is calibrated to meet the specifications stated on the spec sheet. (2) We offer a factory calibration “-FC” as an option that is a certificate of the standard calibration points at the time of manufacture, for a small fee. (3) We can also provide a NIST-traceable calibration for an extra charge per gage if that is required. To get the NIST-traceable calibration, you would simply add a “-NIST” to the end of your part number. NIST-traceable calibrations will come with the 6 point calibration certificate. We recommend “periodic calibration” for our Magnehelic, though we leave the specific time-frame up to the end user, since different organizations have different requirements (i.e. government groups often require more frequent calibrations.) If you choose to have the NIST traceable calibration done, the NIST group (the National Institute of Standards and Technology) dictates yearly calibration and it will be printed on the certificate.
Question
I am looking to measure velocity in a 4" pipe that is used as air conveyance. We use an eductor and a single stage blower to produce air flow. I am looking to measure pressure and velocity. I purchased a Dwyer Pitot tube, 167-7 108024-00 for the job, and I want to match with the right gauge. I need to be in the range of 2600 cuft/min at maybe 0.5psi. Can you direct me to the right gauge with that information?
Answer
To monitor flow through your 4” pipe, you will have to size the appropriate differential pressure gage. A very common gage that is used will be our Series 2000 Magnehelic gage. This gage can be ordered with a square root output that will direct read in flow units. Upon ordering this part, you will have to specify the maximum differential pressure at your desired flow rate. The following text will bring you to the equations necessary to compute this differential (velocity) pressure. This can also be found in the APPLICATION GUIDES section of our website.
Question
I have a Magnehelic gage 2000-00N I purchased for a clean room. Should the installers set the "set" screw to get the gage back to (0) or will that mess up the calibration? My invoice # if you need to look at what I purchased is 04844623.
Answer
After the Magnehelic has been installed, disconnect pressure lines to vent both sides of the gage to the atmosphere and re-zero. This will not mess up the calibration. This should be done occasionally.
Question
What restrictions, if any, are imposed for the Magnehelic® and Photohelic® gages in vacuum service?
Answer
In applications involving higher vacuums than 20" Hg, leakage due to gage housing porosity becomes the limiting factor.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-135 Silicone rubber gasket for panel mounting (Series 2000, DM-2000, DM-1000, 605) 1-3 days*
$5.40
A-286 4-1/2" Gage panel mounting flange 1-3 days*
$16.05
A-299 Mounting bracket flush mount Magnehelic® gage in bracket. Bracket is then surface mounted . Steel with gray hammertone epoxy finish. 6.3" x 7.7" x 4.0", 1.30 lb. 1-3 days*
$41.55
A-300 Flat aluminum bracket for flush mounting Magnehelic® gage. 6.8" x 6.0" x .1", .35 lb. 1-3 days*
$36.65
A-310A 3-way vent valve, plastic, 1/8" NPT to 1/4" metal tubing, 80 psi rating, replaces former Model A-310 (brass). 2.3" x .8" x .1", .10 lb. 7-8 Weeks*
$23.75
A-320-B-SS Instrument enclosure, 304SS, brushed finish, compatible with 2000 Magnehelic® gage, DM-2000 differential pressure transmitter 1-3 days*
$847.65
A-320-B1 Weatherproof enclosure, ABS, compatible with Series 3000MR/MRS Photohelic®, Series 605 Magnehelic®, Series DH3 Digihelic® (to fit, the casing on the electrical plug must be removed), Series 2000 Magnehelic® with medium and high pressure options 1-3 days*
$326.00
A-320-BC Weatherproof enclosure, ABS, compatible with Series 2000 Magnehelic®, DM-1000 DigiMag®, DM-2000, Series 605 (with -SS option), instruments with backwards compatible bezel option 1-3 days*
$326.00
A-321 Brass safety relief valve, protects Magnehelic® gage or Photohelic® switch/gage against over pressure due to regulator failure, etc, opens at 10 psi. Mounts in tee fitting. 1/4" NPT(M) (use two for DP application). .5" x .5" x 1.5", .10 .lb 1-3 days*
$57.25
A-368 Surface mounting plate, aluminum, for Magnehelic® gage. 1-3 days*
$10.55
A-369 Stand-hang bracket, aluminum, for Magnehelic® gage. 1-3 days*
$16.50
A-371 Surface mounting bracket, use with Photohelic® switch/gage on horizontal or vertical surfaces, also for Capsu-Photohelic® switch/gage on vertical only. Also Magnehelic® -MP, -HP models. 1-3 days*
$52.10
A-401 Plastic carrying case (7-9/16" x 5-7/8" x 2-13/16"). 1-3 days*
$35.60
A-432 Plastic carrying case for Magnehelic® gage of standard range, except high pressure connection, includes 9 ft (2.7m) of 3/16" ID rubber tubing, stand-hang bracket & terminal tube with holder. 9.1" x 7.4" x 3.6", 1.30 .lb 1-3 days*
$64.00
A-448 3-piece magnet kit for mounting Magnehelic® gage directly to a magnetic surface, 3.3" x 1.7" x .5", .20 .lb 1-3 days*
$14.70
A-464 Flush mount kit for Magnehelic® gages (Magnehelic® sold separately) 1-3 days*
$28.10
A-464-SS Stainless steel flush mounting kit for the Magnehelic® gages (Magnehelic® sold separately) 1-3 days*
$131.45
A-481 Installer kit, (includes 2 static pressure tips and PVC tubing). 1-3 days*
$6.60
A-605 Air filter kit - adapts any standard Magnehelic® gage for use as an air filter gage. Includes aluminum surface mounting bracket with screws, (2) 5 ft (1.5 m) lengths of 1/4" aluminum tubing, (2) static pressure tips & (2) molded plastic vent valves. 1-3 days*
$49.80
A-605B Air filter kit with (2) plastic open/close valves, (2) 4" steel static tips, tubing & mounting flange 1-3 days*
$39.15
A-605C Air filter kit with (2) plastic open/close valves, (2) plastic static tips, tubing & mounting flange 1-2 Weeks*
$30.70
A-607 Mounting panel for Magnehelic® 1-2 Weeks*
$6.30
A-610 Pipe mounting kit for 1-1/4" to 2" pipe. 5.6" x 4.6" x 1.4", 1.0 .lb (Magnehelic® sold separately) 1-3 days*
$36.65
200068-51 Mounting hardware kit for standard Magnehelics® (not MP or HP). Included in the kit: 2 each: A-339 adapters, A-330 pipe adapters; 3 each: mounting lugs, long screws, short screws) 1-3 days*
$12.40