Series 607 Differential Pressure Transmitter

Series 607 Differential Pressure Transmitter

Series WWDP Differential Pressure Transmitter

Series WWDP Differential Pressure Transmitter

Series 605 Magnehelic® Differential Pressure Indicating Transmitter

Same Size as Standard Magnehelic® Differential Pressure Gage

The Series 605 Magnehelic® Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure. The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system. The easily read dial gage is complimented by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gage mechanical design and Series 600 transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 10 to 35 VDC supply.

NIST CALIBRATION available in Product Configurator.

Please see Series AT-605 for ATEX approved.

Product Applications

  • Monitor pressures in ducts, rooms, or total building pressures
  • Filter monitoring
  • Local indication of clean room pressures with process signal sent to control room
Starting at $451.35
Filter By
Grouped product items
Model Description Availability* Qty Price
605-0 Differential pressure indicating transmitter, range 0-.50" w.c., max. pressure 10 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy. 1-3 days*
$451.35
605-00N Differential pressure indicating transmitter, range .05-0-0.2" w.c., max. pressure 10 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy. 1-3 days*
$516.90
605-1 Differential pressure indicating transmitter, range 0-1.0" w.c., max. pressure 10 psi (1.7 bar), ±2% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-10 Differential pressure indicating transmitter, range 0-10" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-11 Differential pressure indicating transmitter, range .25-0-.25" w.c., max. pressure 10 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy. 1-3 days*
$516.90
605-125PA Differential pressure indicating transmitter, range 0-125 Pa, max. pressure 10 psi (68.95 kPa), ±2% electrical accuracy, ±3% mechanical accuracy. 1-3 days*
$451.35
605-2 Differential pressure indicating transmitter, range 0-2.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-20 Differential pressure indicating transmitter, range 0-20" w.c., max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-250PA Differential pressure indicating transmitter, range 0-250 Pa, max. pressure 10 psi (68.95 kPa), ±2% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-3 Differential pressure indicating transmitter, range 0-3.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-50 Differential pressure indicating transmitter, range 0-50" w.c., max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-500PA Differential pressure indicating transmitter, range 0-500 Pa, max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-60PA Differential pressure indicating transmitter, range 0-60 Pa, max. pressure 10 psi (68.95 kPa), ±2% electrical accuracy, ±4% mechanical accuracy. 1-3 days*
$516.90
605-6 Differential pressure indicating transmitter, range 0-6.0" w.c., max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy. 1-3 days*
$451.35
605-2-WP Differential pressure indicating transmitter, range 0-2.0" w.c. with weatherproof housing 1-3 days*
$1,517.35

Specifications

GAGE SPECIFICATIONS
Service:
Air and non-combustible, compatible gases.
Wetted Materials:
Consult factory.
Accuracy:
See Ordering page.
Stability:
±1% FS/yr.
Pressure Limits:
See Ordering page.
Temperature Limits:
20 to 120°F (-6.67 to 48.9°C).
Process Connections:
1/8" female NPT.
Size:
4" (101.6 mm) dial face, 5" (127 mm) OD x 2-11/16" (68.3 mm).
Weight:
1 lb, 12.6 oz (811 g).
Agency Approvals:
CE.
TRANSMITTER SPECIFICATIONS
Accuracy:
See Ordering page (includes linearity, hysteresis, and repeatability).
Temperature Limits:
20 to 120°F (-6.67 to 48.9°C).
Compensated Temperature Range:
32 to 120°F (0 to 48.9°C).
Thermal Effect:
±0.025% FS/°F (0.045% FS/°C).
Power Requirements:
10 to 35 VDC (2-wire).
Output Signal:
4 to 20 mA.
Zero and Span Adjustments:
Protected potentiometers.
Loop Resistance:
DC: 0 to 1250 Ω maximum.
Current Consumption:
DC: 38 mA maximum.
Electrical Connections:
Screw terminal block.
Mounting Orientation:
Diaphragm in vertical position. Consult factory for other position orientations.

Features

  • Easy to read gage permits viewing from far away
  • Patented design provides quick response to pressure changes means no delay in signaling and alerting to critical situations
  • Durable and rugged housing and high-quality components combined provides long-service life and minimized down-time
  • Optional stainless steel bezel is the same installation diameter as Magnehelic® gage and simplifies field upgrade to 605 indicating transmitter

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Model Chart

EXAMPLE 605 00N AT Series 605-00N-AT Magnehelic® Differential Pressure Indicating Transmitter, range 0.05-0-0.20" w.c., with aluminum tag.
SERIES 605     Magnehelic® Differential Pressure Indicating Transmitter
RANGE   00N
0
1
2
3
6
10
11
12
13
20
30
50
60PA
125PA
250PA
500PA
1KPA
1.5KPA
  0.05-0-0.20" w.c.
0 to .50" w.c.
0 to 1.0" w.c.
0 to 2.0" w.c.
0 to 3.0" w.c.
0 to 6.0" w.c.
0 to 10" w.c.
0 to ±0.25" w.c.
0 to ±60 Pa
100-0-100 Pa
0 to 20.0" w.c.
0 to 30.0" w.c.
0 to 50.0" w.c.
0 to 60 Pa
0 to 125 Pa
0 to 250 Pa
0 to 500 Pa
0 to 1.0 kPa
0 to 1.5 kPa
OPTIONS     AT
G
HC
M
NIST
R
SS
ST
TA
WP
Y
Aluminum Tag
Green Scale Overlay
Horizontal Calibration
Mirror Scale Overlay
NIST Certificate of Calibration
Red Scale Overlay
Brushed 304 Stainless Steel Bezel
Stainless Steel Tag
Tilt Angle from Vertical in Degrees
Weather Proof Enclosure
Yellow Scale Overlay

Questions

Question
How will installation of a Magnehelic® gage 150' away from the pressure source affect accuracy?
Answer
Accuracy will not be affected, but response time will be increased in proportion to the length of the tubing.
Question
Can the standard Magnehelic® or Capsuhelic® gage be installed outdoors?
Answer
Yes. Front covers are sealed with "O" rings. Capsuhelic vent holes are plugged with foam, and the new high impact acrylic lens material is very resistant to ultra-violet fogging. Additional care is recommended to lead pressure connections downward from the gage and provide as much protection from the elements as possible
Question
Can a standard Magnehelic® gage be used for natural gas or propane service?
Answer
No. As the silicone diaphragm will be attacked by these gases. A Buna-N diaphragm should be specified.
Question
What happens when a Magnehelic® gage equipped with the low temperature option is operated below -20 degrees Fahrenheit (-29 degrees Celsius)?
Answer
Below that temperature the accuracy of the gage deteriorates beyond our published specification due to stiffening of the diaphragm.
Question
Is National Institute of Standards and Technology traceability available for the Magnehelic® Gage?
Answer
No. But Magnehelic® gages can be given a special 6 point calibration check with an NIST traceable master gage and a certificate can be supplied.
Question
How do I hook up my Magnehelic® Gage?
Answer
In Bulletin A-27 under operation, it explains how to connect the Magnehelic to the following applications: positive pressure, negative pressure, and differential pressure.
Question
What restrictions, if any, are imposed for the Magnehelic® and Photohelic® gages in vacuum service?
Answer
In applications involving higher vacuums than 20" Hg, leakage due to gage housing porosity becomes the limiting factor.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-135 Silicone rubber gasket for panel mounting (Series 2000, DM-2000, DM-1000, 605) 1-3 days*
$5.40
A-277 Precision resistor, 250 ohm 1-3 days*
$12.90
A-298 Flat aluminum bracket for flush mounting (for Series A3000 Photohelic®, Series 4000 Capsuhelic®, Series 605, and Series 3000MR) 1-3 days*
$37.65
A-320-B1 Weatherproof enclosure, ABS, compatible with Series 3000MR/MRS Photohelic®, Series 605 Magnehelic®, Series DH3 Digihelic® (to fit, the casing on the electrical plug must be removed), Series 2000 Magnehelic® with medium and high pressure options 1-3 days*
$326.00
A-320-BC Weatherproof enclosure, ABS, compatible with Series 2000 Magnehelic®, DM-1000 DigiMag®, DM-2000, Series 605 (with -SS option), instruments with backwards compatible bezel option 1-3 days*
$326.00
A-489 4" 303 SS straight static pressure tip with flange, 1/4" hose barb. 1-3 days*