Series AVLV Air Velocity Transmitter

Series AVLV Air Velocity Transmitter

RHPX-2SDA0-00

RHPX-2SDA0-00

Series RHPX Humidity and Temperature Transmitter

Passive Temperature Outputs, Indoor and Outdoor Enclosures

The Series RHPX Humidity and Temperature Transmitter accurately monitors the humidity and temperature for building control functions to maximize occupant comfort and minimize operating costs. Featuring capacitance polymer humidity sensors, models are available in 2% and 3% accuracies. An optional two-line alphanumeric LCD display is available. The high accuracy, long term stability and reliable operation in multiple enclosure styles make the Series RHPX an excellent choice for monitoring humidity and temperature in building energy management systems, commercial HVAC systems, clean rooms, museums and data centers. The Series RHPX can be optionally configured to supply absolute or relative humidity or dew point in addition to enthalpy.

USA: California Proposition 65
WARNING: This product can be expose you to chemicals including methylene chloride, which is known to the State of California to cause cancer, and bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. California Residents: View the Proposition 65 Warning.

Product Applications

  • Air economizers
  • Outdoor humidity and temperature reference
  • Pool room humidity monitoring
  • Commercial HVAC systems
  • Clean rooms
  • Museums
  • Data centers
 
Starting at $185.00
Grouped product items
Model Description Availability* Qty Price
RHPX-2SDA0-00 Relative Humidity/Temperature transmitter, 2% small enclosure, duct, analog output 1-2 Weeks*
$200.00
RHPX-2SDA0-00-LCD Relative Humidity/Temperature transmitter, 2% small enclosure, duct, analog output, LCD 1-2 Weeks*
$266.05
RHPX-3SDA0-00 Relative Humidity/Temperature transmitter, 3% small enclosure, duct, analog output 1-2 Weeks*
$185.00
RHPX-3SDA0-00-LCD Relative Humidity/Temperature transmitter, 3% small enclosure, duct, analog output, LCD 1-2 Weeks*
$251.05

Specifications

Humidity Measurement Range:
0 % to 100 % humidity.
Temperature Measurement Range:
-40 °C to 60 °C (-40 °F to 140 °F).
Humidity Sensor Accuracy:
Model specific, ±2 % or ±3 %, at 10 % - 90 % RH and 25 °C (77 °F).
Temperature Sensor Accuracy, Solid State Band Gap:
±0.9°F @ 77°F (±0.5°C @ 25°C).
Temperature Sensor Accuracy, Thermistor:
±0.2°C @ 25°C (±0.36°F @ 77°F) (analog models only).
Temperature Sensor Accuracy, RTD:
DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F) (analog models only).
Resolution:
Relative humidity: 0.1%; temperature: 0.1°F/°C; absolute humidity: 0.1 g/m3.
Humidity Analog Output:
4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable.
Active Temperature Analog Output:
4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable.
Passive Temperature Sensors:
Types II and III: Solid state band gap; Curves A, B, and F: Thermistor; Curves D and E: Platinum RTD DIN 385, Balco 1K (analog models only, availability is sensor configuration dependent).
Network Communication:
BACnet MS/TP protocol or Modbus® RTU (communicating models only).
Supported BAUD Rates:
9600, 19200, 38400, 57600, 76800, 115200 (communicating models only).
Termination Load:
120 Ω (communicating models only).
Operating Temperature Range:
-40°C to 60°C (-40°F to 140°F); With LCD: -20°C to 60°C (-4°F to 140°F).
Power Requirements:
Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac.
Wiring Connection:
Removable terminal block.
Electrical Entry:
1/2˝ NPS thread. Cable gland included.
Humidity Sensor:
Capacitive polymer.
Enclosure Material:
UL 94 V-0.
Enclosure Rating:
IP66.
Optional Display:
Two (2) lines of alphanumeric characters with eight (8) characters per line.
Weight:
Duct: 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1247.4 g (2.75 lb).
Storage Temperature:
-40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F).
Additional calculations:
Absolute humidity: (0 to 50) g/m3 or (0 to 3000) lb/mmcf; dew point -75 °C to 60 °C (-102 °F to 140 °F); enthalpy (-40 to 411) kj/kg or (-17 to 177) Btu/lb.
Compliance:
BTL, CE, UL 2043*, UL-60335-2-40**.
* UL 2043 compliance limited to models:
    RHPX-XS(B,S,W) Wall Mount
    RHPX-XS(D,E)-XX-X Plastic Probe Duct Mount without LCD
    RHPX-XS(F,G)-XX-X SSTL Duct Mount with LCD
    RHPX-XL(B,S,W) Large Wall Mount without LCD
    RHPX-XL(H) Large Wall Mount without LCD & Solar Radiation Shield
** Meets UL-60335-2 clause 30.103DV.1 through UL2043 compliance

Features

  • Reduced installation costs with multiple on-board sensors
  • Minimal maintenance with UV rated outdoor enclosures
  • UL 2043 compliant allows installation into the plenum space
  • Easy installation with removable terminal block, attached lid, and cable management

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-RHPX-PLATE RHPX duct mount adapter plate to RHP duct mount 1-2 Weeks*
$6.00
RHRS 6 plate solar radiation shield for sintered filter version RH transmitters. 1-3 days*