Series AT-DHC ATEX/IECEx Approved Digihelic® Differential Pressure Controller
The Series AT-DHC ATEX/IECEx Approved Digihelic® Differential Pressure Controller is a 3-in-1 instrument possessing a digital display gage, control relay switches, and a transmitter with both current and voltage outputs. Combining these 3 features allows the reduction of several instruments with one product, saving inventory, installation time, and cost. The Series AT-DHC ATEX/IECEx Approved Digihelic® differential pressure controller is the ideal instrument for hazardous area pressure, velocity, and volumetric flow applications reading in several commonly used engineering units with optional unidirectional or bidirectional ranges. These units achieve a 1.5% or better accuracy on extremely low ranges, and 0.5% accuracy for ranges at or above 1 in w.c. Calibration can be performed in the field (in safe zone only) making maintaining its accuracy more manageable. Additionally, the Series AT-DHC Digihelic® differential pressure controller includes 2 SPDT control relays with adjustable deadbands. Programming the unit is simple using the built-in menu. With scalable 4-20 mA, selectable voltage process outputs, and selectable Modbus® or BACnet communication, this controller can easily fit into your application. Flameproof enclosures are available in aluminum and can include a glass window for viewing process information and set point status on the digital display.
Please see Series DHC for non-ATEX/IECEx approved.
California Residents: Click Here for Proposition 65 WARNING.
Product Applications
- Hazardous area pressure, velocity, and volumetric flow measurement and switching
Specifications
- Service:
- Air and non-combustible, compatible gases.
- Wetted Materials:
- Consult factory.
- Accuracy:
- ±0.5% FSO for all ranges, except 0.5 in w.c. @ ±1% FSO, and ranges at or below ±0.25 in w.c. @ ±1.5% FSO.
- Stability:
- < ±1% / year FSO.
- Temperature Limits:
- -4 to 158°F (-20 to 70°C). (Note: Product temperature limits differ from case).
- Pressure Limits:
- See pressure limit chart.
- Power Requirements:
- 12-28 VDC, 12-28 VAC 50 to 400 Hz.
- Output Signal:
- 4-20 mA (4-wire); 0-10 V, 0-5 V, 1-5 V, and 2-10 V (4-wire).
- Response Time:
- 400 ms (damping set to 0).
- Zero and Span Adjustments:
- Accessible via menus in safe zone only.
- Power Consumption:
- 3 VA max.
- Display:
- Backlit LCD display, LED setpoint indicators.
- Mounting Orientation:
- Not position sensitive.
- Enclosure Rating:
- IP66 (IP65 for versions VS1, VS2, and VL1).
- Housing Material:
- Aluminum.
- Finishing:
- Texture epoxy coat RAL7038.
- Process Connections:
- 1/8˝ female NPT ports.
- Electrical Connections (Device):
- 15 pin male high density D-sub connection; 18˝ (46 cm) cable with 15 conductors included.
- Electrical Connections (Enclosure):
- Two 1/2˝ NPT female. Cable gland not included.
- Switch Type:
- 2 SPDT relays.
- Electrical Rating:
- 1 A @ 30 VAC/VDC.
- Set Point Adjustment:
- Adjustable via menus in safe zone only.
- Communication:
- BACnet MS/TP or Modbus® RTU.
- Supported Baud Rate:
- 9600, 19200, 38400, 57600, 76800, 115200.
- Device Load:
- 1/8 unit load.
- Thermal Effects:
- 0.02% FS / °F (0.036% FS / °C).
- Weight:
- 12.3 lb (5.6 kg).
- ATEX Certificate:
- INERIS 21ATEX0033X.
- IECEx Certificate:
- IECEx INE 21.0064X.
- Compliance:
- ATEX: 0080 II 2G Ex db IIC T5, T6 Gb
-60°C ≤Ta ≤+50°C (T6) -60°C ≤Ta ≤+60°C (T5) II 2D Ex tb IIIC T75 °C Db;
IECEx: Ex db IIC T5, T6 Gb -60°C ≤Ta ≤+50°C (T6) -60°C ≤Ta ≤+60°C (T5) Ex tb IIIC T75°C Db.
Features
- All the capabilities and value of the Series DHC in an ATEX/IECEx approved enclosure
- Long service life and minimized downtime due to durable, rugged housing and high-quality components
- High impact strength and high temperature rated for applications where hazardous environments exist
Product Literature
Manuals
Catalog Pages
Drawings
- AT-101NA-DHC (VL1/W/DTC013).dwg
- AT-101NA-DHC (VL1/W/DTC013).pdf
- AT-101NA-DHC (Vll/DTC013).dwg
- AT-101NA-DHC (Vll/DTC013).pdf
- AT-101NA-DHC (VLO/DTC003).dwg
- AT-101NA-DHC (VLO/DTC003).pdf
- AT-101NA-DHC (VLO/W/DTC003).dwg
- AT-101NA-DHC (VLO/W/DTC003).pdf
- AT-101NA-DHC (VS1/DTC014).dwg
- AT-101NA-DHC (VS1/DTC014).pdf
- AT-101NA-DHC (VS1/W/DTC014).dwg
- AT-101NA-DHC (VS1/W/DTC014).pdf
- AT-101NA-DHC (VS2/DTC015).dwg
- AT-101NA-DHC (VS2/DTC015).pdf
- AT-101NA-DHC (VS2/DTC015/W).dwg
- AT-101NA-DHC (VS2/DTC015/W).pdf
- AT-101NA-DHC (VSO/DTC004).dwg
- AT-101NA-DHC (VSO/DTC004).pdf
- AT-101NA-DHC (VSO/DTC004/W).dwg
- AT-101NA-DHC (VSO/DTC004/W).pdf
Model Chart
AT-DHC PRESSURE CONTROLLER WITH ATEX ENCLOSURE AT-101NA-DHC-X-XXXX 1ST SYMBOL (1ST X) RANGE 002 0.25 INWC 003 0.5 INWC 004 1 INWC 006 2.5 INWC 008 5 INWC 009 10 INWC 010 25 INWC 011 50 INWC 012 100 INWC 202 ±0.25 INWC 203 ±0.5 INWC 204 ±1 INWC 206 ±2.5 INWC 208 ±5 INWC 209 ±10 INWC 053 60 PA 055 125 PA 056 250 PA 253 ±60 PA 255 ±125 PA 256 ±250 PA 082 6 MMWC 084 25 MMWC 282 ±6 MMWC 284 ±25 MMWC 2ND SYMBOL (2ND X) HOUSING COVER B BLIND W GLASS WINDOW 3RD SYMBOL (3RD X) PRESSURE PORT/VENTING VALVE MATERIAL 1 BRASS 2 STAINLESS STEEL 4TH SYMBOL (4TH X) PRESSURE PORT/VENTING VALVE VS0 STD PRESSURE PORT 1/8” FEMALE NPT/NO VENTING VALVE VL0 LD PRESSURE PORT 1/8” FEMALE NPT/NO VENTING VALVE VS1 STD PRESSURE PORT 1/8” FEMALE NPT/STD VENTING VALVE VS2 STD PRESSURE PORT 1/8” FEMALE NPT/LD VENTING VALVE VL1 LD PRESSURE PORT 1/8” FEMALE NPT/LD VENTING VALVE 5TH SYMBOL (5TH X) CABLE ENTRY 12 1/2" NPT ANSI/ASME B1.20.1