Globe

Globe

Globe valves are linear motion valves for flow control of gases, liquids, and steam. Models are pneumatic actuated and economical valves. Coupled with the high flow capacity, the Hi-Flow™ control valve maintains a wide rangeability of 50:1. A few models have metal-to-metal seating that ensures excellent flow control and shut-off service.

Set Descending Direction
View as Grid List

1 Item

per page
  1. Series 2000VA/3000WA Hi-Flow™ Control Valve
    Hi-Flow™ Control Valve is a single seated, top or cage guided glob ...
    Starting at $1,804.40
Set Descending Direction
View as Grid List

1 Item

per page

Questions

Question
Hi-Flow™ control valves call out ANSI B16.104 Class IV flow leakage. What does this mean?
Answer
ANSI B16.104 is a testing specification for control valves. This specification has actually been superseded by ANSI/FCI 70-2 Class IV. The class IV designation defines the allowable amount of leakage through the valve seat in the closed position. Class IV allows for .01 percent of the rated flow (Cv), to pass through the seat. Class IV is common for metal to metal seated valves.
Question
What if I need parts for my Hi-Flow™ control valve?
Answer
Many Hi-Flow™ valves have been in service for 15+ years with all original parts. However, since Hi-Flow™ valves are commonly used in steam service, a severe application, some parts may wear over time. Unlike other control valves, Hi-Flow™ valves are designed with removable seat rings making repair or replacement of components an option. Although all parts are available, you will probably never need more than a seat ring, plug assembly, and stem packing to have a valve that is like new.